Electronic Thermostat HONEYWELL LineVoltPRO TL8230A1003/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TL8230A1003/U

The Honeywell LineVoltPRO TL8230A1003/U is a double-pole, 7-day programmable electronic thermostat for line-voltage electric heating.

3,600 Wmax. at 240 V
Programmablebuilt-in schedule
5 yearsmanufacturer warranty
Programmable
Get my installed price 514 316-2973

Quick facts

Model numberTL8230A1003/U
ProgrammableYes
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty5 years

The Honeywell LineVoltPRO TL8230A1003/U is a double-pole electronic thermostat, 7-day programmable, designed for line voltage electric heating. What sets it apart comes down to one word: double-pole. Where a single-pole thermostat interrupts only one conductor, this one acts on both conductors of the 208/240 V circuit. It is the configuration we choose when the electrical installation or the way the room is used requires both sides of the circuit to be cut.

At AirGreen, we install this model in homes, cottages and small buildings heated with electric baseboards, where owners want both an automatic heating schedule and a control that matches the existing circuit.

Double-pole or single-pole: making the right choice

The LineVoltPRO family includes two programmable thermostats that look very much alike. The TL8130A1005/U is single-pole and handles up to 16.7 A. The TL8230A1003/U shown here is double-pole and handles up to 15 A, which is 3600 W at 240 V or 3120 W at 208 V. So the choice is not made at random: it depends on the type of circuit, how the old thermostat was wired and the total wattage of the heating units in the room. Before every replacement, our technicians note this information and recommend the right version.

In a cottage or a seasonal room, cutting both conductors is often what you want when closing off part of the house. The thermostat's switch can be set to On/Off or On/Standby mode, depending on how you intend to use it. In a home occupied year-round, this model offers the same comfort as its single-pole sibling, with a different electrical design.

Heating systems it is designed for

The TL8230A1003/U controls a single heating stage of 208/240 VAC electric resistance heating: electric baseboards, radiant ceilings, convectors and fan-forced heaters. It cannot be used with a furnace, a central heat pump, a wall-mounted heat pump or hydronic floor heating, which require 24 V controls or dedicated controls. If your home has several types of equipment, we help you choose a consistent control for each one.

7-day programming and precise control

7-day programming lets you set a different schedule for each day of the week. The temperature drops when the room is empty and rises again before you get back, without you having to think about it. Electronic control to +/-1 °F avoids the wide temperature swings typical of mechanical thermostats. In practical terms, the room stays more stable: less of a chill between two cycles, less overheating after a long heating cycle.

Early Start calculates when heating needs to begin so that the setpoint is reached at the scheduled time. You program “21 °C at 6:30”, and the thermostat takes care of starting a little earlier. A heating indicator on the screen confirms when the baseboards are running.

A backlit screen and quiet relays

The large backlit LCD screen of 2.67 sq in. clearly displays the room temperature and the setpoint. It is easy to read from a distance, which is handy in an entrance, a hallway or a bedroom. The thermostat is soundproofed to reduce relay clicking, a real advantage over older electronic controls that click with every cycle.

No batteries are needed: the thermostat is powered by the circuit and requires no maintenance to speak of. You do not have to worry about a screen going blank in the middle of winter because a battery is dead.

Installation, settings and everyday use

A double-pole line voltage thermostat is connected to a 208 or 240 V circuit, and the power must be fully shut off at the electrical panel. Our technicians check the voltage, measure or calculate the baseboard load and make sure it stays under the 15 A limit. They also check the condition of the conductors, the electrical box and the existing connections, which are sometimes worn in older homes.

Once the thermostat is in place, we set up the following with you:

  1. the switch mode, On/Off or On/Standby;
  2. Early Start;
  3. a weekday and weekend schedule that matches your routine;
  4. the comfort and energy-saving setpoints for each period.

The compact 124 x 70 x 23 mm (4.875 x 2.75 x 0.875 in.) housing, in Premier White, suits residential interiors as well as light commercial spaces.

Saving through the winter without giving up comfort

In Québec, heating accounts for a large share of electricity use in a home heated with baseboards. The simplest way to reduce it is to avoid heating an empty room to the same temperature as an occupied one. With a programmable thermostat in each room, the bedroom can stay cooler during the day, the home office can drop at night and the bathroom can be warm when you wake up. We recommend moderate setbacks, especially in north-facing or poorly insulated rooms, so that the room warms back up quickly in the morning.

In a cottage, Off mode or a low setpoint while you are away helps limit consumption. Remember, however, to keep the temperature high enough to protect the plumbing once the cold season sets in.

Maintenance tips

A light dusting of the housing is enough. Check the schedule when the clocks change and every season, and avoid placing a lamp, a TV or a piece of furniture directly under the thermostat: the heat it gives off would throw off the reading of the thermistor sensor.

Technical specifications

  • Type: double-pole line voltage electronic thermostat, 7-day programmable
  • Stages: 1 heating stage
  • Systems: 208/240 VAC electric resistance heating — baseboards, radiant ceilings, convectors, fan-forced heaters
  • Power supply: 208/240 VAC, 50/60 Hz, no batteries
  • Maximum load: 15 A (3600 W at 240 V, 3120 W at 208 V)
  • Control: electronic, +/-1 °F
  • Display: large backlit LCD screen (2.67 sq in.), heating indicator
  • Features: Early Start, On/Off or On/Standby switch, soundproofed relays
  • Sensor: thermistor
  • Dimensions: 124 x 70 x 23 mm (4.875 x 2.75 x 0.875 in.)
  • Colour: Premier White
  • Approvals: UL, cCSAus

AirGreen, your heating contractor

AirGreen is a family HVAC business based in Montréal for more than 15 years, holding an RBQ licence, with a showroom in Boucherville. We install heat pumps, furnaces and thermostats, and we know that a good baseboard thermostat, properly chosen and properly wired, makes a real difference to a room's comfort. Our technicians explain the settings and leave you with a thermostat that is ready to use.

To buy the Honeywell LineVoltPRO TL8230A1003/U and have it professionally installed, contact AirGreen. We work in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: HONEYWELL LineVoltPRO TL8230A1003/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeLine-voltage thermostatHONEYWELL LineVoltPRO TL8230A1003/U
For208/240 V AC resistive electric heating — baseboards,…Systems
Power208/240 VAC, 50/60 Hz, no batteriesPower supply
Capacity1 heating stageStages
02 · Compatible?

Is the HONEYWELL LineVoltPRO TL8230A1003/U compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpNoA central system is controlled in 24 V: see 24 V thermostats.
Dual energy (heat pump + furnace)NoDual energy is controlled in 24 V: see 24 V thermostats.
Electric furnaceNoA furnace is controlled in 24 V: see 24 V thermostats.
Gas or oil furnaceNoA furnace is controlled in 24 V: see 24 V thermostats.
Steam, gravity or hot waterNoA hydronic system needs a 24 V thermostat or a hydronic control.
Baseboards, convectors, radiant ceilingYesBaseboards, convectors and radiant ceilings, within the thermostat’s load range.
Fan-forced heaterYesThe spec sheet lists fan-forced heaters.
Electric floor heatingNoFloor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller.
03 · Wiring

A thermostat that works on 120/240 V

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the HONEYWELL LineVoltPRO TL8230A1003/U before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Your savings

How much good programming can save you

Set up your typical week. The math follows the rule published by Natural Resources Canada.

06 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.

07 · Room by room

What each room costs

An interactive drawing of what this kind of control does day to day.

08 · Head to head

The HONEYWELL LineVoltPRO TL8230A1003/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

09 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

10 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01LoadWe add up the heaters on the circuit and check the thermostat’s range.
  2. 02Shut-offBreaker shut off at the panel, 2- or 4-wire circuit identified.
  3. 03MountingWiring, mounting, power back on.
  4. 04TestHeating checked room by room.
  5. 05SettingsSchedule, connection and app if the model has them.
11 · Specifications

HONEYWELL LineVoltPRO TL8230A1003/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralTypedouble-pole line voltage electronic thermostat, 7-day programmable
GeneralStages1 heating stage
GeneralSystems208/240 V AC resistive electric heating — baseboards, radiant ceilings, convectors, fan-forced heaters
ElectricalPower supply208/240 VAC, 50/60 Hz, no batteries
ElectricalMaximum load15 A (3600 W at 240 V, 3120 W at 208 V)
GeneralControlelectronic, +/-1 °F
Format and contentsDisplaylarge backlit LCD screen (2.67 sq. in.), heating indicator
GeneralFunctionsearly start, On/Off or On/Standby switch, silenced relays
GeneralProbethermistor
Format and contentsDimensions124 x 70 x 23 mm (4.875 x 2.75 x 0.875 in.)
Format and contentsColourPremier White
GeneralCertificationsUL, cCSAus
12 · Questions

Frequently asked questions about the HONEYWELL LineVoltPRO TL8230A1003/U

Short answers, no detours.

What does the HONEYWELL LineVoltPRO TL8230A1003/U work with?

According to the manufacturer’s sheet: 208/240 V AC resistive electric heating — baseboards, radiant ceilings, convectors, fan-forced heaters.

What load can it control?

Up to 3,600 W at 240 V, per the manufacturer’s sheet.

Who installs it?

Our technicians: the circuit is shut off at the panel, the heater load is checked, then the thermostat is wired and tested.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

What is the warranty?

5 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.