In some electric heating installations, the thermostat doesn't control the baseboards directly.
Quick facts
In some electric heating installations, the thermostat doesn't control the baseboards directly. Instead, it sends a low-voltage signal to a relay, which switches the 240 V load. This setup is found in large rooms, commercial spaces, systems whose load exceeds the capacity of an ordinary thermostat, or when the thermostat has to be located far from the heaters. The Honeywell TH114-A-024T/U is designed for that role. As the 24 V version of the TH114-A non-programmable thermostat, it offers the same backlit screen and the same ease of use, but it works together with an Aube electromechanical relay from the RC840 or RC840T series.
A 24 V control for relay-operated electric heating
The TH114-A-024T controls one stage of electric heating (baseboards, radiant ceilings, convectors or fan-forced heaters) through an Aube RC840/RC840T relay. This relay is not included, yet it is essential for operation, and we plan for it in your project when one isn't already in place. The thermostat connects to terminals R, C and W, runs on 24 VAC with a maximum current of 0.5 A and needs no batteries. It is CSA approved.
Why use a relay
A line voltage thermostat must carry all the current of the heaters it controls. When the load is large or spread out, or when running 240 V wiring to the thermostat isn't desirable, the switching is handed to a relay installed near the heaters or the panel. The thermostat itself only carries a low-voltage signal. The TH114-A-024T follows that logic and runs at 4 cycles per hour, a pace suited to electromechanical relays.
A setting not to forget
The AF/F selector on this model must be set to AF for this use. This installation detail, easy to overlook, is part of our technicians' systematic checks at commissioning. The backlit screen shows the temperature and a heating power indicator, and the ON/STANDBY switch lets you shut it down at the end of the season. The stated accuracy is ±0.5 °C.
Technical specifications
- Stage: 1 heating, electric heating through an external relay
- Equipment: electric baseboards, radiant ceilings, convectors or fan-forced heaters controlled by an Aube RC840/RC840T relay
- Power: 24 VAC, 0.5 A max; wired connection; 4 cycles per hour
- Requires an Aube RC840/RC840T series electromechanical relay (not included)
- Terminals: R, C, W
- Non-programmable
- Display: backlit LCD; heating power indicator
- ON/STANDBY switch
- AF/F selector to be set to AF
- Setting range: 5 to 30 °C (40 to 86 °F); accuracy: ±0.5 °C
- No batteries; CSA approval; connectivity: none
- Dimensions: 124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in.)
- Colour: white
Installing the thermostat and the relay
Installation has two parts. First, the RC840 or RC840T relay, connected to the line voltage heating circuit, is installed or checked according to the heaters' load. Then the thermostat is connected to the relay with a low-voltage cable on terminals R, C and W. Our technicians cut power at the panel, check that no voltage is present, verify the load controlled by the relay and make sure 24 V is available at the thermostat. After powering up, they set the AF/F selector to AF, then run a heating test to check that the relay responds properly to every call.
Everyday use
For the occupant, nothing sets the TH114-A-024T apart from an ordinary thermostat. You set the temperature with the up and down buttons, read the value on the backlit screen, and the power indicator shows when the heat is on. The control has no clock to set and needs no attention after a power outage. In spring, the STANDBY position suspends the heating call. This simplicity suits a large living room as well as a commercial space where several people adjust the temperature.
Habits that make a difference
The simplicity of a non-programmable thermostat appeals to many families and to seniors who want a control without menus. To save with it, a few habits are enough: avoid turning the setpoint all the way up to warm up faster (the heat doesn't come any faster), lower the temperature in unoccupied rooms and turn it down at night. A steady, precise control then lets you live at a slightly lower setpoint without discomfort, which means a more reasonable bill over the winter.
The 24 V versions of the TH114/TH115 family
Our selection includes three Honeywell 24 V thermostats for relay-operated electric heating. The TH114-A-024T/U, shown here, is non-programmable and works with an RC840/RC840T electromechanical relay at 4 cycles per hour. The TH114-A-024T-15S/U, also non-programmable, uses 15-second cycles with an RT850/RT850T solid-state relay for an even steadier temperature. The TH115-A-024T/U adds 7-day programming. If you prefer direct control without a relay, the line voltage TH114-A thermostats suit loads up to 4,000 W at 240 V.
Maintenance and long-term use
An electronic thermostat for electric heating needs almost no maintenance. Wipe the housing with a dry cloth and never block the vents: the sensor needs to read the room air. Keep curtains, furniture and objects well away from the baseboards so air can circulate freely, which helps the control maintain a steady temperature. In spring, simply turn the setpoint down to the minimum or put the control on standby if it allows it. If the display stays blank or the room no longer heats, don't take the unit apart: turn off the breaker and contact us.
AirGreen, your heating and air conditioning contractor
AirGreen Inc. is a family air conditioning and heating business active in Montréal for more than 15 years. With an RBQ licence, our team installs, replaces and maintains HVAC systems throughout Montréal, Laval, Longueuil, the North Shore and the South Shore. The thermostat is the part you touch every day: we treat it as seriously as the equipment it controls. Before recommending a model, we look at what's actually behind your wall, meaning the number of wires, the voltage and the type of equipment, so the control we choose works properly from the very first start-up. Our Boucherville showroom also lets you see several thermostats in person and talk them over with an advisor.
To replace your current control, contact AirGreen today for the sale and installation of this model by our technicians, anywhere in Montréal, Laval, Longueuil, the North Shore and the South Shore. We check your installation, set an appointment and leave the thermostat set to your preferred temperature.
Key facts: HONEYWELL TH114-A-024T/U
Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.
Is the HONEYWELL TH114-A-024T/U compatible with your heating?
Two steps, thirty seconds. The verdict takes your system and your wiring into account.
Full compatibility table
The terminals behind the thermostat
Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.
Try the HONEYWELL TH114-A-024T/U before you buy
Raise the setpoint, change the mode: see how it responds.
Winter, Rate Flex D and rebates: what this thermostat changes
With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. Turning the setpoint down a few degrees during those hours is what counts.
The HONEYWELL TH114-A-024T/U or its closest sibling?
The most useful comparison: the model right next to it in our catalogue.
The right thermostat in three questions
If this model is not the right one for you, the page says so and shows you which one is.
Installed and set up by our technicians, in five steps
What we do at your place, in order. The on-site estimate is free.
- 01InspectionEquipment, stages to control and existing wiring.
- 02C wireCommon wire added if the model needs it and it is missing.
- 03MountingWall base, terminal wiring, cover plate if needed.
- 04SettingsEquipment type, stages, dual energy and accessories.
- 05Start-upConnection, app, schedule and tests with you.
HONEYWELL TH114-A-024T/U specifications
From the manufacturer’s sheet. Type a word: the list filters as you write.
No line matches. Try another word.
Frequently asked questions about the HONEYWELL TH114-A-024T/U
Short answers, no detours.
What does the HONEYWELL TH114-A-024T/U work with?
According to the manufacturer’s sheet: electric baseboards, radiant ceilings, convectors or forced-air units controlled by an Aube RC840/RC840T relay.
Does it need a C wire?
Per the spec sheet, it can run on batteries; a common wire is still recommended when available.
Can it control electric baseboards?
No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.
Can it be controlled remotely?
Not directly: it has no built-in Wi-Fi.
What is the warranty?
3 years, per the manufacturer’s information.
Does AirGreen install it?
Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.
No question matches. Call us at 514 316-2973.
Your thermostat, installed and set up by our technicians
We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.