Electronic Thermostat HONEYWELL TH115-A-024T/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TH115-A-024T/U

When an electric heating system is controlled by relay, you often lose access to common programmable thermostats designed for line voltage.

24 Vlow-voltage thermostat
Programmablebuilt-in schedule
3 yearsmanufacturer warranty
Programmable
Get my installed price 514 316-2973

Quick facts

Model numberTH115-A-024T/U
ProgrammableYes
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty3 years

When an electric heating system is controlled by relay, you often lose access to common programmable thermostats designed for line voltage. The Honeywell TH115-A-024T/U fills that gap. It's a 7-day programmable low-voltage 24 V control that works with an Aube RC840 or RC840T relay to switch the load of baseboards, radiant ceilings, convectors or fan-forced heaters. You get a full heating schedule, Early Start and temporary override, even on an installation where the thermostat doesn't control the heaters directly.

Weekly programming for relay-operated systems

The TH115-A-024T connects to terminals R, C and W and runs on 24 VAC, with a maximum current of 0.5 A. The RC840/RC840T relay is not included and must be part of the installation; we include it in the quote when one isn't already in place. The thermostat works in 15-minute cycles, suited to electromechanical relays. It is CSA approved and needs no batteries.

Complete programming

7-day programming lets you set a different schedule for each day. That's an asset in commercial spaces closed on weekends, home offices used only on certain days or homes whose occupants have varying schedules. The Early Start function begins heating before a period starts, so the temperature is reached at the scheduled time. Temporary override allows a one-off adjustment without touching the program.

Ambient and floor modes

The TH115-A-024T offers ambient and floor heating modes. Ambient mode regulates based on the room's air temperature, which matches the usual use with baseboards or convectors. The mode is chosen during setup, according to the type of system being controlled, and our technicians set it to suit your installation. The backlit LCD screen makes reading and programming easier.

Technical specifications

  • Stage: 1 heating, electric heating through an external relay
  • Equipment: electric baseboards, radiant ceilings, convectors or fan-forced heaters controlled by an Aube RC840/RC840T relay
  • Power: 24 VAC, 0.5 A max; wired connection; 15-minute cycles
  • Requires an Aube RC840/RC840T series electromechanical relay (not included)
  • Terminals: R, C, W
  • 7-day programmable
  • Ambient and floor heating modes
  • Display: backlit LCD
  • Early Start; temporary override
  • Setting range: 5 to 30 °C (40 to 86 °F)
  • CSA approval; connectivity: none
  • Dimensions: 124 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
  • Colour: white

A two-part installation

The relay is the heart of the system: it receives the line voltage load and switches it according to the thermostat's signal. So our technicians start by checking or installing the RC840 or RC840T relay, making sure the load of the connected heaters stays within its capacity. They then connect the thermostat with low-voltage cable to terminals R, C and W, after cutting the power and checking that no voltage is present. Commissioning includes setting the time and day, choosing the heating mode, a first schedule set up with you and a full test of the heating cycle.

Making good use of programming

For a business, the typical schedule provides a comfort setpoint during opening hours and a reduced setpoint in the evening and on weekends. For a home, four key moments often structure the day: wake, leave, return and sleep. The TH115-A-024T applies these schedules automatically, day after day. When you need to break the routine, temporary override gives you the heat you want without undoing the programming, which resumes at the next period. The backlit screen makes it easy to read the setpoint and the temperature at all times.

Everyday comfort and savings

A well-set heating schedule lets you enjoy a warm house when you're there, and save when you're not. That's especially useful in Québec, where the heating season lasts a good part of the year. The programmable thermostat applies the same settings every day, then lets you change the setpoint temporarily when needed, for example on a day off or a cooler evening. You stay in control without losing the benefits of the schedule.

Where it fits in the family

The TH115-A-024T/U is the programmable version of the Honeywell 24 V thermostats for relay-operated electric heating. The TH114-A-024T/U offers non-programmable control with the same type of RC840/RC840T relay. The TH114-A-024T-15S/U, also non-programmable, uses 15-second cycles with an RT850/RT850T solid-state relay. For direct control without a relay, the line voltage TH115-A models offer the same 7-day programming. The right choice depends on the type of relay in place and how interested you are in programming.

Practical tips

At the start of the cold season, check that every thermostat in the house shows a consistent temperature and that the heaters respond. Dust the baseboards with the breaker off, and keep them clear of furniture and curtains. The rest of the year, a wipe of the housing with a dry cloth is enough. If a room always seems colder than the others despite an identical setpoint, the control's location, the insulation or the installed heating capacity may be the cause; our technicians can assess the situation.

One point of contact, from selection to commissioning

At AirGreen, the person who advises you works with the technicians who come to your home. This continuity avoids misunderstandings: the model ordered matches your installation, the wiring is checked on site and the settings are made to suit your lifestyle. As a family business established for more than 15 years and holding an RBQ licence, we serve homeowners, authorized tenants and building managers in Montréal, Laval, Longueuil, the North Shore and the South Shore. We know the region's housing stock well, from 1950s duplexes to new suburban homes, and we know what surprises an old wall box can hold. You can also visit our Boucherville showroom to compare controls before making your choice.

To get this thermostat installed properly, reach out to the AirGreen team. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore, and we take care of everything: system check, product supply, installation, testing and an explanation of the settings.

01 · Key facts

Key facts: HONEYWELL TH115-A-024T/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

Type24 V thermostatHONEYWELL TH115-A-024T/U
Forelectric baseboards, radiant ceilings, convectors or…Devices
Power24 VAC, 0.5 A maxPower supply
CapacityR, C, WTerminals
02 · Compatible?

Is the HONEYWELL TH115-A-024T/U compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpDepends on the modelDepends on the number of stages: see the spec sheet below.
Dual energy (heat pump + furnace)Depends on the modelDepends on the model: dual energy needs backup-heat control. See the spec sheet.
Electric furnaceYes24 V control of the furnace.
Gas or oil furnaceYes24 V control of the furnace; the thermostat does not touch the fuel supply.
Steam, gravity or hot waterDepends on the modelPossible in 24 V: see the manufacturer’s sheet.
Baseboards, convectors, radiant ceilingNoA baseboard runs on 120/240 V: it needs a line-voltage electronic thermostat.
Fan-forced heaterNoA fan-forced heater needs a line-voltage thermostat rated for fans.
Electric floor heatingNoElectric floor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller or a compatible Wi-Fi module.
03 · Wiring

The terminals behind the thermostat

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the HONEYWELL TH115-A-024T/U before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Your savings

How much good programming can save you

Set up your typical week. The math follows the rule published by Natural Resources Canada.

06 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.

07 · Head to head

The HONEYWELL TH115-A-024T/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

08 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

09 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01InspectionEquipment, stages to control and existing wiring.
  2. 02C wireCommon wire added if the model needs it and it is missing.
  3. 03MountingWall base, terminal wiring, cover plate if needed.
  4. 04SettingsEquipment type, stages, dual energy and accessories.
  5. 05Start-upConnection, app, schedule and tests with you.
10 · Specifications

HONEYWELL TH115-A-024T/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralStage1 heat, electric heating via external relay
GeneralDeviceselectric baseboards, radiant ceilings, convectors or forced-air units controlled by an Aube RC840/RC840T relay
ElectricalPower supply24 VAC, 0.5 A max; hardwired connection; 15-minute cycles
GeneralOtherRequires an Aube RC840/RC840T series electromechanical relay (not included)
ElectricalTerminalsR, C, W
GeneralOther7-day programmable
GeneralOtherRoom and floor heating modes
Format and contentsDisplayBacklit LCD
GeneralOtherEarly start (Early Start); temporary override
GeneralAdjustment range5 to 30 °C (40 to 86 °F)
ConnectivityCSA certification; connectivitynone
Format and contentsDimensions124 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
Format and contentsColourwhite
11 · Questions

Frequently asked questions about the HONEYWELL TH115-A-024T/U

Short answers, no detours.

What does the HONEYWELL TH115-A-024T/U work with?

According to the manufacturer’s sheet: electric baseboards, radiant ceilings, convectors or forced-air units controlled by an Aube RC840/RC840T relay.

Can it control electric baseboards?

No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

What is the warranty?

3 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.