Quick facts
In Québec, most residential electric baseboards are powered at 240 V. For these installations, the Honeywell TH115-A-240S-B/U is a versatile programmable control that is slim and easy to read. It offers 7-day programming with four periods per day, a large backlit LCD screen and single-pole relay switching, suited to the most common heating circuits. Its profile, only 23 mm thick, keeps it discreet on the wall, and its hidden programming buttons keep the front uncluttered. It is the model we gladly recommend for upgrading an entire electrically heated home.
The 240 V single-pole version of the TH115-A line
The TH115-A-240S-B controls baseboards, radiant ceilings, convectors and fan-forced heaters on 240 V or 208 V circuits. Its maximum load is 16.7 A resistive, which is 4000 W at 240 V or 3475 W at 208 V. The single-pole (SPST) relay is epoxy-encapsulated to reduce switching noise. Advanced temperature control narrows the gap between the setpoint and the actual temperature, for more consistent comfort than a mechanical thermostat provides.
Designed for Québec seasons
The ON/STANDBY switch lets you put the heating to rest at the end of the season without losing the programming. Daylight saving time changes happen automatically in spring and fall. Battery-free backup keeps your settings during a power outage, so you do not have to reprogram every thermostat in the house after a storm. Vacation mode holds a reduced temperature while you are away, and the Early Start function reaches the target temperature at the scheduled time.
Useful compatibility
The TH115-A-240S-B is compatible with Aube RC840 series relays and with the Aube CT240/CT241 telephone controller. It carries UL and CSA approvals (CAN/CSA-C828-06). This compatibility gives you flexibility for installations that call for it, for example when a relay is part of the heating system design.
Technical specifications
- Stage: 1 heating, electric resistance heating
- Equipment: electric baseboards, radiant ceilings, convectors or fan-forced heaters
- Voltage: 240/208 VAC, 50/60 Hz
- Maximum load: 16.7 A resistive (4000 W at 240 V, 3475 W at 208 V)
- Single-pole switching (SPST relay), epoxy-encapsulated for quieter operation
- 7-day programmable, 4 periods per day
- Large backlit LCD screen; heating power indicator
- ON/STANDBY switch for the end of the season
- Early Start; temporary override; hidden programming buttons
- Vacation mode; automatic daylight saving time change
- Battery-free backup: no reprogramming after an outage
- Setting range: 5 to 30 °C (40 to 86 °F)
- Compatible with Aube RC840 relays and the Aube CT240/CT241 telephone controller
- UL and CSA approvals (CAN/CSA-C828-06); hardwired, no batteries
- Dimensions: 124 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
- Colour: white
What our technicians check
Replacing an electric heating thermostat is a chance to check the condition of the circuit. Our technicians look at the condition of the wires in the box, the quality of the old connections, the actual voltage and the total wattage of the connected heating units. These checks confirm that the chosen model suits the load, and then it is wired correctly. Once the control is in place, we run a heating test and check that the room temperature responds as expected. When several rooms have old mechanical thermostats, we can replace them all in a single visit.
Programming without the hassle
The programming buttons are hidden under the front cover: day to day, only the temperature adjustment buttons are visible, which prevents accidental changes. During installation, our technicians set the time and a first schedule with you. You can then temporarily override the program with a single button, for example to warm up the room on a bitterly cold evening; the program resumes at the next period. When you equip several rooms in the house with the same model, you only learn it once, and everyone in the family knows how to adjust their room.
Everyday comfort and savings
A well-set heating schedule lets you enjoy a warm house when you are there and save when you are not. That is especially useful in Québec, where the heating season lasts a good part of the year. The programmable thermostat applies the same settings every day, then lets you temporarily change the setpoint when needed, for example on a day off or a cooler evening. You stay in control without losing the benefits of the schedule.
240S, 240D or 120S: choosing the right version
The TH115-A comes in three line voltage versions. The TH115-A-240S-B/U, shown here, is single-pole and handles up to 4000 W at 240 V: it is the most common version for residential baseboards. The TH115-A-240D-B/U is double-pole and handles up to 3600 W at 240 V, for installations where both conductors of the circuit need to be controlled. The TH115-A-120S/U is for units powered at 120 V, up to 2000 W. For those who do not need programming, the TH114-A-240S-B/U offers the same slim housing in a non-programmable version.
Maintaining your electric heating
The electronic thermostat has no moving parts to replace, which makes it very durable. Maintenance comes down to keeping the housing clean and unobstructed. The units it controls do deserve a little attention, though: dust the baseboards and convectors before the cold season, make sure nothing blocks the air outlet of unit heaters, and visually check older units. If a baseboard gives off an unusual smell or shows signs of overheating, turn off its circuit and have it inspected.
An installation designed for your home
We do not sell a thermostat the way you sell a box off a shelf. Every AirGreen recommendation starts from your actual installation: type of unit, voltage, number of conductors, location of the box and your family's habits. As a Montréal family HVAC business active for more than 15 years and holding an RBQ licence, we serve Montréal, Laval, Longueuil, the North Shore and the South Shore. Our technicians come with the tools needed to check the circuit, install the control level, run operating tests and show you the settings that matter. You are left with a clean installation and a thermostat you know how to use. To see the products up close, our showroom in Boucherville is open to you.
To order this thermostat and have it installed correctly the first time, contact AirGreen. Our team serves Montréal, Laval, Longueuil, the North Shore and the South Shore, and every installation ends with complete tests and a short demonstration of the settings.
Key facts: HONEYWELL TH115-A-240S-B/U
Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.
Is the HONEYWELL TH115-A-240S-B/U compatible with your heating?
Two steps, thirty seconds. The verdict takes your system and your wiring into account.
Full compatibility table
A thermostat that works on 120/240 V
Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.
Try the HONEYWELL TH115-A-240S-B/U before you buy
Raise the setpoint, change the mode: see how it responds.
How much good programming can save you
Set up your typical week. The math follows the rule published by Natural Resources Canada.
Winter, Rate Flex D and rebates: what this thermostat changes
With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.
What each room costs
An interactive drawing of what this kind of control does day to day.
The HONEYWELL TH115-A-240S-B/U or its closest sibling?
The most useful comparison: the model right next to it in our catalogue.
The right thermostat in three questions
If this model is not the right one for you, the page says so and shows you which one is.
Products that go with the HONEYWELL TH115-A-240S-B/U
Parts named in its spec sheet that we sell and install.
Installed and set up by our technicians, in five steps
What we do at your place, in order. The on-site estimate is free.
- 01LoadWe add up the heaters on the circuit and check the thermostat’s range.
- 02Shut-offBreaker shut off at the panel, 2- or 4-wire circuit identified.
- 03MountingWiring, mounting, power back on.
- 04TestHeating checked room by room.
- 05SettingsSchedule, connection and app if the model has them.
HONEYWELL TH115-A-240S-B/U specifications
From the manufacturer’s sheet. Type a word: the list filters as you write.
No line matches. Try another word.
Frequently asked questions about the HONEYWELL TH115-A-240S-B/U
Short answers, no detours.
What does the HONEYWELL TH115-A-240S-B/U work with?
According to the manufacturer’s sheet: electric baseboards, radiant ceilings, convectors or forced-air units.
What load can it control?
Up to 4,000 W at 240 V, per the manufacturer’s sheet.
Who installs it?
Our technicians: the circuit is shut off at the panel, the heater load is checked, then the thermostat is wired and tested.
Can it be controlled remotely?
Not directly: it has no built-in Wi-Fi.
What is the warranty?
3 years, per the manufacturer’s information.
Does AirGreen install it?
Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.
No question matches. Call us at 514 316-2973.
Your thermostat, installed and set up by our technicians
We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.