EMERSON Blue Series 2" 1F82-0261 Thermostat | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: 1F82-0261

A central heat pump with a backup stage, and a household that is out all week: the 1F82-0261 runs both heating stages on a 5-1-1 schedule.

2/1heat pump with backup
5-1-1weekdays, Saturday, Sunday
5 yearsmanufacturer warranty
Programmable
Get my installed price 514 316-2973

Quick facts

Model number1F82-0261
ProgrammableYes
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty5 years

Your home is heated by a central heat pump backed by a second heating stage, and it sits empty during the day from Monday to Friday. You need a heat pump thermostat that tells the compressor apart from the backup, and a schedule that follows your week. The Blue Series 2" 1F82-0261 (the White-Rodgers line from EMERSON) does both: 2 heating stages, 1 cooling stage and 5-1-1 programming.

Two heating stages, three schedules

  • 2/1 heat pump: a single-stage compressor plus one backup or emergency stage for heating, one stage for cooling.
  • 5-1-1 programming: weekdays, Saturday and Sunday, 4 periods a day, with temporary override or setpoint hold.
  • Adjustable differential: 1.2 °F in heating and cooling.
  • Short-cycle protection and Cool Savings: two separate features, one for the compressor, the other for the cooling peak.
  • Program memory: your schedule survives a power failure.
  • Screen: 2 sq. in. blue backlit LCD with large characters and display recalibration.

What it controls, and what it does not

The 1F82-0261 is designed for a single-stage heat pump with backup heat. A furnace on its own needs a conventional thermostat, and the manufacturer’s documents do not provide dual-fuel control for this model. It is not meant for hot water or steam systems either, or for baseboards, electric floor heating or wall or ducted heat pumps.

Models to compare

In its 2025 cross-reference table, the brand lists the EMERSON 80 Series 1F83H-21PR to replace the 1F82-0261. Its sheet lists a dual-fuel logic option, which the 1F82-0261 documents do not provide. That model runs a 7-day or 5-1-1 schedule, or none at all, and takes setpoints up to 37 °C. If you would rather skip programming altogether, the EMERSON Blue Series 2" 1F89-0211 handles the same 2/1 heat pump, is the same size and has no schedule. Both accept up to 1.5 A per terminal and 2.5 A total, whereas the 1F82-0261 load does not exceed 1.0 A per terminal and 1.5 A total.

How AirGreen wires it

The 1F82-0261 wires to the R, C, W2, Y, O/B, G and L terminals: we identify each heat pump wire, with the backup stage going to W2, and power the thermostat on batteries or through the C wire. Then we set up your weekday, Saturday and Sunday programs with you. A free in-home estimate comes before anything else.

Manufacturer document: 1F82-0261 installation instructions (37-7022). Sold and installed by AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: EMERSON Blue Series 2" 1F82-0261

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

Type24 V thermostatEMERSON Blue Series 2" 1F82-0261
Forsingle-stage heat pump with backup heatSystems
Powerbatteries or hardwiredPower supply
ConnectionnoneConnectivity
02 · Compatible?

Is the EMERSON Blue Series 2" 1F82-0261 compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpYesHandles heat pumps (2H/1C per the spec sheet).
Dual energy (heat pump + furnace)NoThe manufacturer’s documents do not provide dual-energy control for this model.
Electric furnaceNoHeat pump thermostat: a furnace on its own needs a conventional thermostat.
Gas or oil furnaceNoHeat pump thermostat: a furnace on its own needs a conventional thermostat.
Steam, gravity or hot waterNoDesigned for heat pumps, not for hot water or steam systems.
Baseboards, convectors, radiant ceilingNoA baseboard runs on 120/240 V: it needs a line-voltage electronic thermostat.
Fan-forced heaterNoA fan-forced heater needs a line-voltage thermostat rated for fans.
Electric floor heatingNoElectric floor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller or a compatible Wi-Fi module.
03 · Wiring

The terminals behind the thermostat

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the EMERSON Blue Series 2" 1F82-0261 before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Your savings

How much good programming can save you

Set up your typical week. The math follows the rule published by Natural Resources Canada.

06 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.

07 · Head to head

The EMERSON Blue Series 2" 1F82-0261 or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

08 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

09 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01InspectionEquipment, stages to control and existing wiring.
  2. 02C wireCommon wire added if the model needs it and it is missing.
  3. 03MountingWall base, terminal wiring, cover plate if needed.
  4. 04SettingsEquipment type, stages, dual energy and accessories.
  5. 05Start-upConnection, app, schedule and tests with you.
10 · Specifications

EMERSON Blue Series 2" 1F82-0261 specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralStagesheat pump: 2 heat / 1 cool (single-stage compressor and one backup or emergency stage)
GeneralSystemssingle-stage heat pump with backup heat
GeneralProgramming5-1-1 day, 4 periods per day; temporary override or setpoint hold
ElectricalPower supplybatteries or hardwired; 20 VAC, 50/60 Hz, as printed on the instructions
ElectricalLoad1.0 A per terminal, 1.5 A total
ElectricalTerminalsR, C, W2, Y, O/B, G, L
GeneralSetpoint range7 to 32 °C (45 to 90 °F)
GeneralDifferentialsheat pump: 1.2 °F heat and cool (adjustable)
Format and contentsDisplay2 sq. in. blue backlit LCD, large characters
GeneralFeaturesCool Savings (cooling peak), display recalibration, compressor short-cycle protection, program kept during a power failure
ConnectivityConnectivitynone (no Wi-Fi)
Format and contentsDimensions3-3/4 in. (H) x 4-3/4 in. (W) x 1-1/2 in. (D)
Format and contentsColourwhite
General2025 cross-referencereplaced by the 80 Series 1F83H-21PR
GeneralManufacturer instructions37-7022 (White-Rodgers)
11 · Questions

Frequently asked questions about the EMERSON Blue Series 2" 1F82-0261

Short answers, no detours.

What does the EMERSON Blue Series 2" 1F82-0261 work with?

According to the manufacturer’s sheet: single-stage heat pump with backup heat.

Does it need a C wire?

Per the spec sheet, it can run on batteries; a common wire is still recommended when available.

Can it control electric baseboards?

No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.