Thermostat HONEYWELL T822K1000/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: T822K1000/U

There are still places where an electronic thermostat isn't the best choice: a mechanical room, a warehouse, a garage, a rental unit where you want a sturdy control that nobody will reprogram.

24 Vlow-voltage thermostat
Simpleno app
1 yearmanufacturer warranty
Get my installed price 514 316-2973

Quick facts

Model numberT822K1000/U
ProgrammableNo
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty1 year

There are still places where an electronic thermostat isn't the best choice: a mechanical room, a warehouse, a garage, a rental unit where you want a sturdy control that nobody will reprogram. The Honeywell T822K1000/U meets this need with proven technology. It is a bimetal thermostat, mercury-free, that controls heating only on a 24 V system. It works with no batteries and no display electronics: a setting lever and a built-in thermometer scale on the front are all it needs. It is an honest mechanical control, easy to understand and very unlikely to fail.

The reliability of a mercury-free mechanical control

The bimetal principle has been known for a long time: two metals that expand at different rates bend a strip when the temperature changes. On the T822K1000/U, this movement operates a single-pole, single-throw snap-action switch (SPST), which opens or closes the heating circuit cleanly. No mercury is used. The vented cover improves airflow around the sensing element, which helps give a reading that is more representative of the room. The stated accuracy is ±1°C.

Where it fits

The T822K1000/U controls one heating stage on the R and W terminals. It is suitable for 24 V low-voltage furnaces and boilers, in homes as well as secondary spaces. Since it needs no batteries, there is nothing to keep an eye on: a heated garage or a cottage visited occasionally can stay under its protection all winter with no risk of a dead battery. The Heat-Off switch lets you shut the unit down in the off-season. It mounts directly on the wall or on a vertical electrical box.

A discreet vertical format

At 121 x 73 x 35 mm, the vertical housing fits easily where an old mechanical thermostat used to be. The setting range is 45 to 95°F. The thermometer scale on the front lets you check the room temperature at a glance, and the lever slides to set the setpoint.

Technical specifications

  • Stage: 1 heating (heating only)
  • System: 24 VAC heating
  • Power: 20 to 30 VAC; no batteries (snap-action bimetal)
  • Control: setting lever with built-in thermometer scale (no screen)
  • Non-programmable; connectivity: none
  • Mercury-free bimetal sensing, SPST snap-action switch
  • Vented cover for better sensing
  • System switch: Heat / Off
  • Setting range: 45 to 95°F
  • Accuracy: ±1°C (2°F)
  • Terminals: R, W; wall or vertical electrical box mounting
  • Dimensions: 121 x 73 x 35 mm (4-3/4 x 2-7/8 x 1-3/8 in.), vertical
  • Colour: Premier white

Installation without guesswork

Low-voltage controls are often installed in a hurry, and that is where short cycling, fans that won't stop or units that no longer start come from. Our technicians work methodically: power shut-off, wire identification, check of the 24 V transformer, connection according to the unit's wiring diagram, then setup and a complete test. We also check that the thermostat's height and location allow an accurate reading, away from heat sources and drafts. If any part of the existing installation looks fragile to us, we point it out before closing up.

Use and adjustment

Operation is entirely mechanical. You move the lever to the desired temperature, and the bimetal controls the heating accordingly. Since the setting scale is marked in Fahrenheit, our technicians can show you, during commissioning, the position that matches the temperature you want in Celsius. The thermostat never shuts off, never loses its settings and needs no attention after a power failure. For building managers, this consistency is an asset: once set, the T822K1000/U stays true to its setpoint.

Saving without programming

A non-programmable thermostat can also help lower your heating costs, provided you use it with a bit of discipline. The most effective habit is to lower the setpoint by a few degrees before going to bed or leaving the house for a long period, then raise it again when you return. An accurate control also helps: the closer it holds the temperature to the setpoint, the less you are tempted to turn up the setting to make up for swings. For rooms that are seldom used, a permanently lower setpoint is a simple way to limit energy use in winter.

T822K1000/U or T834N1002/U

The T822K1000/U has a sibling in the same bimetal family: the T834N1002/U. Both share the same vertical housing, the same mercury-free technology and the same 45 to 95°F range. The difference is functional: the T822K1000/U is heating only, while the T834N1002/U adds cooling, a fan switch and manual changeover. For a garage, a boiler room or a house without air conditioning, the T822K1000/U is the logical choice. For a home that wants a digital display, the vertical PRO 1000 is an alternative.

Through the seasons

At the start of fall, take a few minutes to check your thermostat: readable thermometer scale, mode set to heating and an appropriate setpoint. It is also the right time to have your heating unit inspected. Keep the control clean and unobstructed, and avoid moving it yourself: a poorly connected thermostat can prevent the unit from starting.

AirGreen, your heating and air conditioning contractor

AirGreen Inc. is a family-owned air conditioning and heating business active in Montréal for more than 15 years. Holding an RBQ licence, our team installs, replaces and services HVAC systems throughout Montréal, Laval, Longueuil, the North Shore and the South Shore. The thermostat is the part you touch every day: we treat it as seriously as the equipment it controls. Before recommending a model, we look at what is actually behind your wall, meaning the number of wires, the voltage and the type of equipment, so that the chosen control works properly from the first start-up. Our showroom in Boucherville also lets you see several thermostats in person and talk them over with an advisor.

To replace your current control, contact AirGreen today for the sale and installation of this model by our technicians, throughout Montréal, Laval, Longueuil, the North Shore and the South Shore. We confirm your installation, book an appointment and leave the thermostat set to your preferred temperature.

01 · Key facts

Key facts: HONEYWELL T822K1000/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

Type24 V thermostatHONEYWELL T822K1000/U
Power20 to 30 VACPower supply
CapacityR, WTerminals
Wi-FiNoconnection
02 · Compatible?

Is the HONEYWELL T822K1000/U compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpDepends on the modelDepends on the number of stages: see the spec sheet below.
Dual energy (heat pump + furnace)Depends on the modelDepends on the model: dual energy needs backup-heat control. See the spec sheet.
Electric furnaceYes24 V control of the furnace.
Gas or oil furnaceYes24 V control of the furnace; the thermostat does not touch the fuel supply.
Steam, gravity or hot waterDepends on the modelPossible in 24 V: see the manufacturer’s sheet.
Baseboards, convectors, radiant ceilingNoA baseboard runs on 120/240 V: it needs a line-voltage electronic thermostat.
Fan-forced heaterNoA fan-forced heater needs a line-voltage thermostat rated for fans.
Electric floor heatingNoElectric floor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller or a compatible Wi-Fi module.
03 · Wiring

The terminals behind the thermostat

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the HONEYWELL T822K1000/U before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. Turning the setpoint down a few degrees during those hours is what counts.

06 · Head to head

The HONEYWELL T822K1000/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

07 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

08 · The system

Products that go with the HONEYWELL T822K1000/U

Parts named in its spec sheet that we sell and install.

09 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01InspectionEquipment, stages to control and existing wiring.
  2. 02C wireCommon wire added if the model needs it and it is missing.
  3. 03MountingWall base, terminal wiring, cover plate if needed.
  4. 04SettingsEquipment type, stages, dual energy and accessories.
  5. 05Start-upConnection, app, schedule and tests with you.
10 · Specifications

HONEYWELL T822K1000/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralStage1 heat (heat only)
GeneralSystem24 V AC heating
ElectricalPower supply20 to 30 VAC; no batteries (snap-action bimetal)
GeneralControladjustment lever with built-in thermometer scale (no screen)
ConnectivityNon-programmable; connectivitynone
GeneralOtherMercury-free bimetal sensing, snap-action SPST switch
GeneralOtherVented cover for better sensing
GeneralSystem selectorHeat / Off
GeneralAdjustment range45 to 95 °F
GeneralAccuracy±1 °C (2 °F)
ElectricalTerminalsR, W; wall or vertical electrical box mounting
Format and contentsDimensions121 x 73 x 35 mm (4-3/4 x 2-7/8 x 1-3/8 in.), vertical
Format and contentsColourPremier white
11 · Questions

Frequently asked questions about the HONEYWELL T822K1000/U

Short answers, no detours.

Does it need a C wire?

Per the spec sheet, it can run on batteries; a common wire is still recommended when available.

Can it control electric baseboards?

No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

What is the warranty?

1 year, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.