Thermostat HONEYWELL The Round® T87K1015/U | Montreal, Laval, Longueuil, South Shore & North Shore
A home heated by a furnace or a boiler, without central air conditioning, needs only one thing from its thermostat: to maintain the chosen temperature, day after day, all winter long.
Quick facts
A home heated by a furnace or a boiler, without central air conditioning, needs only one thing from its thermostat: to maintain the chosen temperature, day after day, all winter long. The Honeywell The Round T87K1015/U was designed for this role. The heating-only version of the famous round thermostat, it has a dial marked in Celsius from 5 to 30°C and mercury-free electronic control. This model is also intended for the Canadian market, which explains its factory metric scale. It suits homeowners who want to replace an old round thermostat while keeping the same gesture, but with more accurate control.
One job, done well: heating
The T87K1015/U controls one heating stage on a 24 V system. It works with 2- or 3-wire heating-only systems, on the R, W and Y terminals. The system switch is limited to the Heat and Off positions. This simplicity is intentional: removing functions that are useless in a home without air conditioning also eliminates the risk of mistakes, such as a thermostat accidentally left in cooling mode in the fall.
For hot water and forced-air systems
Many houses and plexes in the area are heated by a boiler that supplies radiators or a network of hot water baseboards, others by a forced-air furnace. In both cases, the T87K1015/U can control the unit at low voltage. The number of cycles per hour can be set to 1, 3, 5 or 9: a slower setting suits hydronic systems, which store and release heat slowly, while a faster setting suits forced air. The technician chooses the appropriate setting during installation.
Simple power
The thermostat runs on battery-assisted power stealing. So there is no need to run a C wire to the thermostat, which is often impossible without opening the walls in an older house. The thermistor-based electronic control has a stated accuracy of ±1°C, a noticeable improvement for those replacing a mechanical model whose temperature drifted over the hours.
Technical specifications
- Stage: 1 heating (heating only)
- Systems: 24 VAC heating only, 2- or 3-wire systems
- System switch: Heat / Off
- Power: 20 to 30 VAC, 50/60 Hz; battery-assisted power stealing
- Display: analog dial (no screen)
- Non-programmable; connectivity: none
- Thermistor-based electronic control, mercury-free
- Accuracy: ±1°C (2°F)
- Adjustable cycles per hour: 1, 3, 5 or 9
- Setting range: 5 to 30°C (Celsius dial)
- Terminals: R, W, Y
- Dimensions: 94 mm diameter x 45 mm deep (3-11/16 x 1-3/4 in.)
- Colour: Premier white
How the installation goes
Our visit starts with a look at the existing installation: number of wires, whether or not there is a C wire, type of unit and condition of the wall box. After de-energizing the equipment, the technician photographs and labels the wiring, removes the old thermostat and mounts the new base level. The technician then connects the conductors, configures the control for your system and runs a real test to watch the burner, heat pump or fan start up. The holes left by the old model are taken into account when choosing the trim plate. Finally, you get a short demonstration of the settings you will use every day.
Through the winter
The dial turns with one motion and shows the setpoint directly in degrees Celsius. For most families, the routine comes down to setting a comfortable temperature at the start of the season, then lowering it as needed at night or during an absence. In spring, the Off position puts the heating to rest until the following fall. The compact round shape, 94 mm in diameter, fits easily where the old thermostat used to be. When an old rectangular model has left marks on the wall, we let you know before the installation so the necessary touch-up can be planned.
Managing heat room by room
With one thermostat per room, each zone of the house can be set according to how it is used. This is one of the great advantages of zoned heating: the family room can stay comfortable while the guest room or an unoccupied office stays cooler. A non-programmable control simply means adjusting the setpoint by hand when your needs change. During the cold months, this room-by-room management is an effective, hassle-free way to limit energy use.
The T87K1015/U and its The Round siblings
Our selection includes three versions of The Round. The T87K1015/U, shown here, is the heating-only Celsius version. The T87N1018/U (Celsius) and T87N1000/U (Fahrenheit) add cooling and a fan switch, for homes with a central air conditioner or a heat pump without backup heat. If you do not have air conditioning and do not plan to add it, the T87K1015/U is the most direct choice. If a central air conditioning project is being considered, it is better to go straight to a heating and cooling model.
Maintenance tips
The thermostat itself only needs occasional dusting. Most of the maintenance concerns the unit it controls: filters to replace as recommended by the manufacturer, annual inspection of the furnace or boiler, cleaning of the heat pump and clearing the outdoor unit in winter. These steps protect your system's performance and let the thermostat do its job properly. AirGreen services furnaces and heat pumps throughout the region, so you can keep everything with the same team.
AirGreen by your side, before and after installation
Replacing a thermostat seems simple, but a poor choice of model or a sloppy connection is paid for later in discomfort and service calls. AirGreen Inc., a family-owned heating and air conditioning business founded in Montréal more than 15 years ago, makes sure every control it installs is suited to its unit and its circuit. Under AirGreen's RBQ licence, our technicians work in houses, condos, plexes and commercial spaces in Montréal, Laval, Longueuil, the North Shore and the South Shore. We keep a record of what was installed in your home, which simplifies any future work, whether it is adding a zone, replacing a unit or reviewing your settings. Our showroom in Boucherville also lets you see several controls side by side.
To order this thermostat and have it installed correctly the first time, contact AirGreen. Our team serves Montréal, Laval, Longueuil, the North Shore and the South Shore, and every installation ends with complete tests and a short demonstration of the settings.
Key facts: HONEYWELL The Round® T87K1015/U
Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.
Is the HONEYWELL The Round® T87K1015/U compatible with your heating?
Two steps, thirty seconds. The verdict takes your system and your wiring into account.
Full compatibility table
The terminals behind the thermostat
Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.
Try the HONEYWELL The Round® T87K1015/U before you buy
Raise the setpoint, change the mode: see how it responds.
Winter, Rate Flex D and rebates: what this thermostat changes
With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. Turning the setpoint down a few degrees during those hours is what counts.
The HONEYWELL The Round® T87K1015/U or its closest sibling?
The most useful comparison: the model right next to it in our catalogue.
The right thermostat in three questions
If this model is not the right one for you, the page says so and shows you which one is.
Installed and set up by our technicians, in five steps
What we do at your place, in order. The on-site estimate is free.
- 01InspectionEquipment, stages to control and existing wiring.
- 02C wireCommon wire added if the model needs it and it is missing.
- 03MountingWall base, terminal wiring, cover plate if needed.
- 04SettingsEquipment type, stages, dual energy and accessories.
- 05Start-upConnection, app, schedule and tests with you.
HONEYWELL The Round® T87K1015/U specifications
From the manufacturer’s sheet. Type a word: the list filters as you write.
No line matches. Try another word.
Frequently asked questions about the HONEYWELL The Round® T87K1015/U
Short answers, no detours.
What does the HONEYWELL The Round® T87K1015/U work with?
According to the manufacturer’s sheet: 24 V AC heating only, 2- or 3-wire systems.
Does it need a C wire?
Per the spec sheet, it can run on batteries; a common wire is still recommended when available.
Can it control electric baseboards?
No. It is a low-voltage (24 V) thermostat. 120/240 V baseboards need a line-voltage electronic thermostat.
Can it be controlled remotely?
Not directly: it has no built-in Wi-Fi.
What is the warranty?
5 years, per the manufacturer’s information.
Does AirGreen install it?
Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.
No question matches. Call us at 514 316-2973.
Your thermostat, installed and set up by our technicians
We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.