Repair of a Goodman Wall-Mounted Heat Pump in Saint-Bruno

Saint-Bruno-de-MontarvilleWall-mounted heat pump Goodman3 min
Réparation d’une Thermopompe Murale Goodman à Saint-Bruno

An outdoor heat pump completely shuts down after a storm

At AirGreen , we were recently called to Saint-Bruno , on Montreal's South Shore , to diagnose and repair a Goodman wall-mounted heat pump whose outdoor unit was no longer starting. The customer had just experienced a violent storm accompanied by a brief power outage—and since then, there has been no sign of life from the compressor.

This typical failure, often caused by a power surge or electronic board failure, required careful inspection to avoid unnecessary compressor replacement.


Initial inspection: a stationary compressor and a silent power supply

Upon our arrival, we carried out a complete visual check of the installation.
The Goodman outdoor unit, securely mounted on galvanized steel wall brackets, had wiring in good general condition . No signs of burning or oxidation were visible at first glance.

Our measurements, however, revealed:

  • No voltage at the outdoor unit terminal block.

  • A partially tripped circuit breaker in the basement electrical panel.

  • A blackened power supply circuit board at the main relay.

These signs indicated a surge caused by lightning , a common scenario during summer storms in Quebec.


In-depth diagnosis: burnt-out control board and blown thermal fuse

We then carried out a detailed electrical diagnosis:

  1. Continuity check on the thermal fuse on the control board.

  2. Power contactor coil test — no response.

  3. Compressor and fan verification via direct power supply (bypass test): both components were functional.

So the verdict was clear: the main control board had suffered a power surge .


Repair steps: rigor and safety

Our AirGreen team carried out the repair following a strict protocol:

1. Securing the electrical circuit

  • Complete power cut at the source.

  • Disconnect and isolate control wires.

  • Check that the main circuit breaker and neutral wire are in good condition.

2. Replacing the control board

  • Installation of a new original Goodman electronic card , compatible with the installed wall-mounted heat pump model.

  • Application of a dielectric protective varnish to prevent future corrosion.

  • Restoration of the wiring according to the manufacturer's diagram.

3. Recalibration and complete test

  • Reconnecting the indoor thermostat and synchronizing the communication signal.

  • Start-up test: The outdoor fan started running immediately , followed by the compressor activating after 15 seconds.

  • Checking the R-410A refrigerant circuit pressure: stable at 115 psi at rest and 380 psi under load.


Final result: restored comfort and enhanced safety

After 40 minutes of continuous testing, the Goodman heat pump was working perfectly in both heating and cooling mode .
The customer noticed:

  • A reduction in operating noise compared to before.

  • Better thermal stability inside.

  • Faster response to thermostat demand.

We also installed an AirGreen surge protector on the electrical circuit, an essential precaution in residential areas prone to frequent thunderstorms.


AirGreen Expertise: The Difference in Every Detail

At AirGreen , every HVAC system repair is carried out with method, precision and transparency .
Our qualified technicians work on most major brands: Goodman, Midea, Fujitsu, Daikin, Gree, Trane, Sharp, and more.

Our guarantees:

  • Precise and documented diagnosis.

  • Use of appropriate replacement parts for each unit.

  • Energy optimization after repair.

  • Personalized advice for the longevity of your device.

We cover all of Greater Montreal, Laval, the North Shore and the South Shore , and we respond to all types of breakdowns, whether it is compressor, electronic card or refrigerant problems .


AirGreen tips to avoid similar breakdowns

To protect your Goodman wall-mounted heat pump:

  • Install an HVAC surge protector directly on the power circuit.

  • Turn off the power during severe thunderstorms .

  • Clean the outdoor unit twice a year to prevent overheating.

  • Have the electronic card checked every 3 to 4 years.

These simple actions extend the life of your system and reduce the risk of costly breakdowns.


Conclusion: A Goodman heat pump saved by AirGreen expertise

Thanks to a quick and methodical intervention, the Goodman wall-mounted heat pump in Saint-Bruno regained its full performance without the need for a complete replacement.
A new demonstration of AirGreen know-how , combining technical expertise, diagnostic precision and commitment to the lasting comfort of our customers.

You made it to the end.Share it with someone it could help.
Near you

More AirGreen jobs in the area

Other jobs, not the one described above.

Keep reading

Latest published jobs

AirGreen Climatisation & Chauffage

The same service at your place?

Cleaning, repair or maintenance: tell us about your unit and we schedule the visit.

  • RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
  • $5M liability insuranceOn every job
  • 15+ yearsFamily-owned, based in Montréal