Project

Installation of an Elios Moovair (R-32 range) wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce

AirGreen installs a Moovair wall-mounted heat pump (R-32) in NDG: 12,000 BTU, condensate pump , discreet capping, rigorous commissioning. Four-season comfort and energy savings, serving Greater Montreal .

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of an Elios Moovair (R-32 range) wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce
Installation of an Elios Moovair (R-32 range) wall-mounted heat pump in Côte-des-Neiges–Notre-Dame-de-Grâce
–chapters in this story
6 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

Four-season comfort in an urban NDG living room: a compact, elegant installation ready for Montreal winters

Client context and objectives

At AirGreen , we are working on a renovated apartment in Côte-des-Neiges–Notre-Dame-de-Grâce . The owner wanted a discreet HVAC solution to cool the living room in the summer and support the heating in the off-season, without major renovations or wasted space. Priorities: silence , efficiency , aesthetics , and reliability in extreme cold.

We offer a wall-mounted Elios Moovair heat pump (R-32 range) , 12,000 BTU configuration - sized after a simplified load calculation (surface area, orientation, insulation, internal inputs). This capacity typically covers 400 to 600 sq. ft. in an open living area, with a comfortable margin for peaks.

Why the Moovair (R-32) range meets the need

  • R-32 refrigerant : better seasonal efficiency than R-410A and reduced charge for the same power.

  • Seasonal efficiency : Competitive SEER/SCOP, ideal for reducing annual consumption.

  • Operation in cold weather : maintaining useful capacity around −25°C , essential for Montreal , Laval , Longueuil , North Shore and South Shore .

  • Acoustics : very low interior noise level, suitable for open living spaces and terraced apartments.

  • Design : minimalist facade integrated into the decor; compact size above the wall elements.

Key words : heat pump , wall-mounted air conditioner , HVAC installation , HVAC maintenance , Montreal , Laval , Longueuil , North Shore , South Shore .

Installation process — clean, fast, controlled

Preparation and tracing

We validate the location at height (~2.20 m) for optimal air diffusion above the furniture and away from heat sources. The installation template is fixed with a laser; we identify the shortest cross to the outside and the route of the connections.

Drilling and passing lines

  • Wall crossing to the required diameter with controlled negative angle.

  • Installation of insulated refrigerant connections, communication cable, and power supply.

  • Discreet white capping near the outlet for a neat finish and easy maintenance.

Condensate management: compact and quiet pump

Since gravity drainage is not possible (horizontal path imposed by the architecture), we install a condensate pump under the interior head. Advantages:

  • No visible gutters and no additional drilling in the baseboard;

  • Safety (level sensor with safety stop);

  • Easy maintenance (accessible hatch).

Connection, vacuuming and commissioning

  • Calibrated flares and tightening torques respected;

  • Deep vacuum with micronmeter until stable;

  • Leak check and R-32 refrigerant charge according to actual length;

  • Settings: blowing mode, sweeping , and set temperature;

  • Measurements of blowing temperature, intensity, and delta T under load.

Aesthetic result and thermal comfort

The wall head integrates into the decor (frames, wall light). The wiring is contained; the condensate box remains compact and harmonized. In use:

  • Responsive and homogeneous cooling of the living room in summer;

  • Efficient additional heating in autumn and spring;

  • Low noise level , ideal for teleworking and home cinema.

Sizing tips for similar spaces

  • 9,000 BTU : Well-insulated bedrooms/offices up to 350 sq. ft.

  • 12,000 BTU : Living rooms 400–600 sq ft, open plan.

  • 18,000 BTU and up : large open areas, high ceilings or multiple doors.
    A load calculation by our advisors remains the reference to avoid over-sizing (short cycles, discomfort) or under-sizing (noise, wear).

Technical points to remember about this pose

  • Controlled working height , clearances respected for air intake and maintenance.

  • Short link length (better efficiency).

  • Discreet path via capping and ceiling; no visual impact.

  • Condensate pump with high level cut-off to prevent any risk of flow.

  • Dedicated power supply and compliant protections.

HVAC Maintenance: The Key to Performance

To maintain performance and longevity:

  1. Filters : clean every 4 to 8 weeks during the season.

  2. Evaporator battery : gentle dusting; avoid corrosive products.

  3. Condensate pump : check the tank and float at the start of summer.

  4. Outdoor unit (if accessible): minimum clearance of 30 cm, cleaning of the fins.

  5. Annual AirGreen inspection : pressure/consumption check, condensate test, electrical check.

Regular HVAC maintenance reduces consumption by up to 10–15% and extends equipment life.

Energy subsidies and savings

Depending on the Energy Star configuration and performance at −25°C , a wall-mounted heat pump like the Moovair (R-32) may be eligible for assistance in effect in Quebec (municipal/provincial programs). We support our customers in:

  • Check eligibility;

  • Prepare evidence (model, serial numbers, photos);

  • Optimize the usage strategy (stable setpoint, automatic ventilation, seasonal programming).

Common Mistakes to Avoid (and How We Prevent Them)

  • Installation too low → air recirculation and discomfort: we respect the manufacturer's clearances.

  • Improvised gravity drain without slope → risk of infiltration: here, pump sized and tested.

  • Connections too long → loss of capacity: layout designed for compactness .

  • Absence of controlled vacuum → humidity in the circuit: we aim for a deep vacuum measured with a micron meter.

What the customer actually gains

  • Immediate summer/winter comfort in the living area.

  • Lower bills compared to traditional air conditioning and electric baseboard heaters.

  • Real estate value : modern, aesthetic, and sought-after equipment in NDG.

  • Peace of mind : guaranteed AirGreen installation and local after-sales service.

What if your project is different?

We cover Montreal , Laval , Longueuil , North Shore and South Shore for various needs: apartments, plexes, houses, offices. Depending on the configuration, we also offer multi-zone , ceiling cassettes , or central systems (R-32/R-454B) when relevant.


Technical sheet — NDG installation (summary)

  • Type : single-zone wall-mounted heat pump

  • Brand : Elios Moovair (R-32)

  • Installed capacity : 12,000 BTU

  • Condensate management : compact pump under the head

  • Finish : minimalist white capping , ceiling path

  • Installation height : ~2.20 m

  • Commissioning : deep vacuum, leak tests, delta T measurements

Your project with AirGreen

We combine thermal diagnostics , grant advice , high-quality HVAC installation and maintenance for lasting comfort. Let's talk about your space: a technical visit is enough to validate the BTU capacity , the routing of the lines , and the safest drainage strategy .

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment