Installation of a MIDEA EVOX G3 1.5 ton electric furnace in Fabreville, Laval: a compact, clean, and four-season comfort-ready central system
AirGreen installs a 1.5-ton MIDEA EVOX G3 electric furnace in Fabreville, Laval: a compact, clean, efficient central system, ideal for confined mechanical spaces.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.
The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.
A shut-off switch near the outdoor unit isolates it safely for service.
Sitting on the indoor module, it moves heat between the house air and the refrigerant.
Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.
Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.
It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.
It runs the heat pump and the backup heat. It must be compatible with the installed system.
A central HVAC installation in a confined space, with meticulous attention to mechanical and electrical details
In Fabreville, in the residential sector of Laval, our AirGreen team installed a MIDEA EVOX G3 1.5 ton electric furnace, also known as an air handler or indoor unit for a central system. This type of equipment plays an essential role in a home equipped with a duct network: it ensures air circulation, uniform distribution of heating and air conditioning, and efficient integration with a central heat pump when the system is configured as such.
In this installation, the mechanical space was limited, with little room around the unit. The photo clearly illustrates the challenge: piping, wiring, tight clearances, close walls, and restricted technical access. This type of configuration is common in Montreal, Laval, Longueuil, on the North Shore and the South Shore, especially in homes where an old central system is being replaced by a newer, more compact solution better suited to current needs.
A logical choice: the MIDEA EVOX G3 1.5 ton electric furnace
The MIDEA EVOX G3 1.5 ton model is particularly interesting for properties where an efficient, discreet, and well-integrated central solution is desired. With a capacity of approximately 18,000 BTU, this unit is suitable for various residential configurations, depending on the area, insulation, duct distribution, and actual heating and cooling needs.
This type of HVAC installation requires much more than a simple connection. It is necessary to check:
- compatibility with the existing duct network;
- available space around the unit;
- service clearances;
- electrical connections;
- condensation drainage;
- seal integrity of connections;
- passage of refrigerant lines;
- protection of exposed cables and pipes;
- future accessibility for HVAC maintenance.
In this project in Fabreville, our goal was clear: to deliver a clean, solid, safe, and easy-to-maintain installation.
What the image reveals about installation quality
The photo highlights several important elements. The MIDEA indoor unit is installed vertically in a narrow technical corner. Pipes and cables are grouped, protected, and neatly routed to connection points. A black protective sleeve covers the vertical lines, improving both the appearance and durability of the installation.
Attention was also paid to the unit's positioning relative to walls and existing connections. In a cramped mechanical room, every inch counts. A poorly placed central furnace can complicate future maintenance, create stress on pipes, or make certain components difficult to access.
At AirGreen, we pay particular attention to these kinds of details, as they directly influence the long-term performance of the system.
A central installation in Fabreville: precision, cleanliness, and adaptation to the existing building
Working with the real constraints of a house in Laval
In Fabreville, as in many neighborhoods of Laval, central systems are often installed in compact mechanical spaces. This could be a basement, a technical closet, a storage room, or a corner set up near a water inlet, an electrical panel, or an existing duct network.
In this project, our team had to contend with several visible constraints:
- limited wall space;
- proximity to a water pipe;
- tight passage for electrical cables;
- need to protect exposed lines;
- maintaining sufficient access to service panels;
- clean integration into an environment already occupied by other mechanical components.
It is precisely these constraints that differentiate a standard installation from a professional HVAC installation. Our team's role is not limited to installing the appliance: we must adapt the installation to the house, without compromising safety, performance, or ease of maintenance.
Why a central system remains an excellent option
A central system with an electric furnace or air handler offers a major advantage: it uses existing ducts to distribute air to multiple rooms. Unlike a wall-mounted air conditioner or a single-zone wall-mounted heat pump, a central system allows for more uniform comfort distribution throughout the house.
For many homeowners in Laval, Montreal, Longueuil, on the North Shore and the South Shore, this solution is particularly appreciated when:
- the house already has a duct network;
- occupants want to avoid multiple visible wall units;
- comfort needs to be distributed across several floors;
- interior aesthetics are a priority;
- the intention is to prepare the house for a high-performance central heat pump;
- maintenance needs to remain centralized and accessible.
The MIDEA EVOX G3 1.5 ton electric furnace fits perfectly into this logic: a compact, modern indoor unit, compatible with a centralized comfort approach.
Common mistakes to avoid during an air handler installation
Installing a central electric furnace may seem simple at first glance, but several errors can impair the system's operation. Among the most common, we observe:
Insufficient clearance around the unit
A unit too close to the wall or jammed behind fixed elements makes maintenance more difficult. One must consider not only the current installation but also future diagnostic, cleaning, and repair visits.
Poorly protected connections
Refrigerant lines, cables, and ducts must be protected against wear, friction, and accidental handling. In the image, the black vertical sleeve plays precisely this role of protection and finishing.
Neglected drainage
An air handler can produce condensation in cooling mode. Improperly designed drainage can cause leaks, humidity, odors, or damage to the building.
Poor adaptation to the duct network
Even an excellent appliance cannot perform well if the ducts are undersized, obstructed, leaky, or unbalanced. During our installations, we always pay attention to the entire system's logic, not just the visible unit.
An AirGreen approach based on real-world installation, not theory
Every project reminds us that a good HVAC installation is built on site, with the building's real-world constraints. In Fabreville, this installation required careful execution, as the space did not allow for improvisation. The unit had to be installed in a way that remained accessible, well-aligned, and safe.
Our team therefore worked with a clear method:
- inspection of the mechanical space;
- validation of existing connections;
- precise positioning of the electric furnace;
- protection of lines and cables;
- electrical and mechanical connection;
- drainage verification;
- operational tests;
- final cleanliness and accessibility check.
This method helps to avoid unpleasant surprises after installation.
MIDEA EVOX G3: a serious option for homes in Laval
The MIDEA EVOX G3 range is increasingly present in residential projects in Quebec. It meets a very concrete demand: to offer a modern, efficient central solution adapted to Quebec winters when paired with a compatible system.
For a home in Fabreville, the 1.5 ton size can be ideal when the building's thermal load matches this capacity. The choice should never be made solely based on area. It is also necessary to consider:
- insulation;
- property age;
- solar orientation;
- number of floors;
- duct quality;
- occupant habits;
- heating and cooling needs;
- compatibility with existing components.
At AirGreen, we always emphasize this point: a good system is not just a good appliance. It's the right appliance, properly sized, well installed, and finely tuned.
Subsidies and eligibility: a factor to validate before installation
For many eligible central systems and heat pumps, programs like LogisVert can influence the client's final budget. Eligibility depends, however, on the exact model, the complete configuration, current criteria, and program requirements at the time of installation.
In a project like this, it's important to validate the information before promising a specific amount. Homeowners in Montreal, Laval, Longueuil, on the North Shore, and on the South Shore often contact us to understand the difference between the price before subsidy and the net cost after reimbursement. Our role is to clearly explain the steps, required documents, and possible limitations.
The importance of maintenance after installation
Once the installation is complete, HVAC maintenance becomes essential. A central system operates with a large volume of air. If filters are neglected or ducts are obstructed, the equipment can lose efficiency, work unnecessarily hard, and shorten its lifespan.
We particularly recommend:
- checking or replacing filters regularly;
- keeping the area around the unit clear;
- monitoring for any unusual noises;
- having the drainage inspected;
- scheduling periodic maintenance;
- never blocking air returns;
- having the system checked before periods of high demand.
A well-maintained air handler contributes to better comfort, improved air quality, and more stable performance.
A clean installation that facilitates future interventions
One of the most important aspects of this installation in Fabreville is the clarity of the work. Components are accessible, lines are protected, and the unit is installed with clear logic. For an owner, this may seem secondary. For an HVAC technician, it is essential.
A clean installation allows for:
- faster diagnosis;
- fewer risks of errors during future service;
- better component protection;
- a professional appearance;
- potentially improved lifespan;
- greater peace of mind for the client.
This is exactly the kind of result we aim for at AirGreen.
A project representative of our work in Laval and Greater Montreal
This installation of a MIDEA EVOX G3 1.5 ton electric furnace in Fabreville, Laval accurately represents our approach: technical, precise, honest, and adapted to the building. We regularly work in homes where mechanical space is limited, where old systems need careful replacement, and where the client wants a reliable solution without transforming the entire house.
Whether in Laval, Montreal, Longueuil, on the North Shore, or the South Shore, our AirGreen team prioritizes durable, well-thought-out, and easy-to-maintain installations. A good central system is not judged only on the day of installation. It is also judged years later, when it continues to operate efficiently, remains accessible for maintenance, and provides stable comfort to occupants.
Conclusion: A well-integrated MIDEA central installation for lasting comfort
The installation of this MIDEA EVOX G3 1.5-ton electric furnace in Fabreville demonstrates the importance of a job well done in tight mechanical spaces. The choice of equipment, line protection, unit alignment, access to service panels, and the quality of connections are all elements that influence final performance.
At AirGreen, we consider each HVAC installation as a complete project, where the appliance's performance must be supported by rigorous execution. For homeowners looking for a reliable, discreet, and well-installed central system in Laval or elsewhere in Greater Montreal, this type of project perfectly illustrates the value of a specialized team.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
The equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
Access protected, old unit disconnected and removed when it is being replaced.
Electric furnace or air handler, with its coil, connected to the supply and return ducts.
On a level base, raised above the snow, with free space all around.
Insulated, they enter through a sealed opening and run to the indoor coil.
Dedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
Leak test, vacuum, start-up, airflow check and a test of both modes.
Filter, thermostat, backup heat in extreme cold: what to know before winter.
- The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
- The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
- Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
- The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
- The outdoor unitOn a level base, raised above the snow, with free space all around.
- The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
- Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
- Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
- The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Check the indoor module's filter.
- Clear winter debris from the outdoor unit.
- Test cooling before the heat arrives.
- Check the filter more often in peak season.
- Keep registers and returns clear.
- Watch condensate drainage near the coil.
- Change or clean the filter.
- Test heating and backup heat before the cold.
- Book periodic maintenance.
- Clear snow around the outdoor unit.
- Store nothing in front of the indoor module.
- Note any unusual noise or smell and call us.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. A central heat pump uses the house's ducts.
It connects to the existing ducts to heat and cool everywhere.
2. In extreme cold, electric backup heat can take over.
The indoor module (furnace or air handler) works with the heat pump and takes over in extreme cold.
3. The filter only gets changed when the unit breaks down.
A dirty filter cuts airflow. It gets checked regularly.
4. You can reuse the old unit's size without checking.
The house may have changed: insulation, windows, added rooms. Capacity is confirmed on site.
0 / 4 right answers
What people ask us about this kind of work
Can I keep my current ducts?
What happens in extreme cold?
Furnace, air handler, ducted: what is the difference?
Are there grants?
Do I need a permit?
How much can I save?
How is the LogisVert assistance calculated?
Will my current thermostat work?
Central or wall units: which one?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).
