Project

Installation of a MIDEA EVOX G3 electric furnace in a horizontal position in an attic in Senneville

In Senneville, AirGreen installs a MIDEA EVOX G3 electric furnace horizontally in a tight attic: adaptation to the framing, insulated ducts, airflow, and technical access carefully planned.

By AirGreen Climatisation & Chauffage Admin17 min read
Installation of a MIDEA EVOX G3 electric furnace in a horizontal position in an attic in Senneville
Installation of a MIDEA EVOX G3 electric furnace in a horizontal position in an attic in Senneville
–chapters in this story
17 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

The job

In Senneville, a MIDEA EVOX G3 installed horizontally where a traditional vertical furnace simply could not fit

This installation carried out by AirGreen in Senneville, in the western part of the Island of Montreal, perfectly illustrates why choosing a central electric furnace cannot be limited to comparing BTU capacities or efficiency ratings. Here, the main challenge was architectural: the indoor system had to be installed directly in a low-clearance attic, beneath a steeply sloped roof, amid existing wood framing and a network of insulated flexible ducts.

The job-site photograph clearly shows the reality encountered by our team. The rafters impose decreasing headroom, several structural elements cross the mechanical area, and the existing ducts already occupy a significant portion of the space. In this configuration, a conventional vertical installation would have been extremely difficult, if not impossible without major modifications.

We therefore integrated the MIDEA EVOX G3 in a horizontal position, on a support structure adapted to the attic. This orientation makes intelligent use of the available length beneath the roof slope while maintaining a logical airflow path and facilitating connection to the existing ductwork.

This is exactly the kind of job where the modular design of the EVOX G3 becomes much more than a feature on a technical data sheet.

A horizontal configuration that directly addresses the constraints of the home

In a conventional basement, a central unit is often installed upright. In this Senneville attic, that solution would have used up valuable headroom and placed certain parts of the equipment directly in the roof slope.

Midea’s documentation specifically provides for several orientations for the EVOX G3: upflow, downflow, right horizontal, left horizontal, as well as low “low-boy” configurations. The manufacturer presents six installation options and specifically emphasizes the value of the modular design for difficult-to-access areas such as attics and basements.

At our Senneville job site, the unit is positioned on its side, parallel to the structural framing. This arrangement preserves as much usable space around the unit as possible.

In the photo, we can also see several indications of the installation work in progress:

  • the the MIDEA EVOX G3 electric furnace rests on a wooden support structure;
  • the unit is installed horizontally beneath the rafters;
  • a level is placed on the cabinet during the work;
  • the existing insulated flexible ducts run around the equipment;
  • a sheet-metal transition is prepared at one end;
  • the service panels remain oriented toward an area where they can be accessed;
  • the coil connections remain accessible despite the limited space.

In an attic installation, these details have a direct impact on future reliability.

Why leveling becomes particularly important in an attic

The visible level on the unit in the job-site photo is not an insignificant detail.

When the heat pump operates in cooling mode, warm, humid air from the home passes over a cold coil. Water naturally forms on this coil and must be collected by the condensate pan before being drained away.

A horizontal unit must therefore be positioned in accordance with the manufacturer's requirements and the planned drainage system.

In a basement, a drainage problem may sometimes be noticed quickly. In an attic, a water leak can remain hidden for some time and affect:

  • the insulation;
  • the ceiling below;
  • the wood components;
  • the interior finishes;
  • the materials around the unit.

For this reason, during an HVAC installation in a Montreal attic, we pay particular attention to mechanical support, unit stability, and drainage.

A modern electric furnace integrated with a central heat pump

The term electric furnace is perfectly understood by Quebec homeowners, but the EVOX G3 is more specifically a central indoor air handler that can be combined with a heat pump.

In a complete configuration, the indoor unit provides, among other things:

  • air circulation through the ductwork;
  • heat exchange with the indoor coil;
  • filtration;
  • the distribution of heating and cooling;
  • the integration of auxiliary electric heating when required.

The outdoor heat pump normally provides much of the heating. The furnace's electric heating elements can then supplement the demand when conditions require it.

For the EVOX G3 platform, Midea offers auxiliary heating modules in various capacities, including configurations of 10 kW, 15 kW, and up to 25 kW, with management that can be handled in several stages depending on the application.

At AirGreen, we do not automatically choose the largest available electrical component. The appropriate power depends in particular on the home’s heating load, the heat pump’s capacity, the electrical panel, and the desired operating strategy.

What is the exact capacity of this EVOX G3 in Senneville?

The rating plate is visible on the side of the photographed unit, but its angle and the image resolution do not allow us to confirm the complete indoor unit number with certainty.

We therefore prefer not to arbitrarily assign a capacity in BTU/h to this installation.

The range MIDEA EVOX G3 presented in the technical documentation covers several capacities. The listed combinations include units of 18,000, 24,000, 30,000, 36,000, 48,000 and 54,000 BTU/h.

This range of capacities is particularly important for central installations. A home in Senneville with large glazed areas, high ceilings, or an older building envelope does not necessarily have the same needs as a home of similar size built to more recent standards.

Sizing must therefore be based on the building and not solely on the capacity of the old unit.

Performance of up to 19 SEER2 depending on the selected combination

The technical specifications for the third-generation EVOX G3 indicate performance of up to 19 SEER2 for certain combinations. The published range also includes values of up to 12.5 EER2, 10.8 HSPF2 and a COP at 5 °F, or approximately -15 °C, that can reach 2,14, depending on the pair of units used.

It is important to clarify that these maximum values cannot automatically be attributed to all EVOX G3 units.

To determine the exact performance of an installation, we need to know:

  1. the indoor unit model;
  2. the outdoor heat pump model;
  3. the corresponding certified combination.

It is this complete combination that determines the system’s official performance.

Heating down to -30 °C: a relevant feature for Senneville

In Greater Montreal, a central heat pump must be selected based on its winter performance and not solely on its summer efficiency.

Midea announces for the EVOX G3 platform a continuous operation down to -30 °C. The documentation also indicates, for the test conditions specified by the manufacturer, a heating capacity that can reach 100% around -25 °C, with a COP that can reach approximately 1,9 under these conditions.

This ability to continue producing heat at low temperatures is particularly interesting for a residence in Senneville, Montréal, Laval, Longueuil, on the North Shore or South Shore, where periods of extreme cold are part of normal operating conditions.

However, this does not mean that the heat pump must operate alone in every situation. Electric backup remains an essential component of many central Québec installations.

The goal is instead to have the heat pump operate efficiently before asking the electrical elements to provide a larger share of the heat.

This Senneville project shows why an HVAC installation in an attic requires much more than simply replacing a unit

Getting the equipment inside is already a challenge

Even before connecting a furnace in an attic, it must be possible to transport it there.

Access openings are often narrow, stairs may be absent, and the space between framing members can make moving a single-piece unit extremely difficult.

The EVOX G3 uses modular interlocking construction, designed to facilitate handling and assembly in confined spaces. Midea’s documentation specifically refers to transporting the unit through attics and to the difficulties encountered with larger traditional appliances.

For our teams, this type of design makes it possible to approach homes differently when access is one of the project’s main obstacles.

We must work with the framing, not against it

The Senneville photo shows a roof whose wooden members run directly through the area where the unit is installed.

In this kind of environment, we must choose the equipment’s location and orientation while taking the existing structure into account.

An HVAC installation obviously does not justify arbitrarily cutting a rafter or structural element simply to gain a few centimetres.

We are instead looking for a configuration that allows the unit to pass between and beneath the existing constraints, while maintaining the clearances required for servicing.

This is one of the reasons why a horizontal unit like the one installed here is particularly appropriate.

Insulated flexible ducts should remain as straight as possible

Several insulated black flexible ducts are clearly visible in the photograph.

These ducts distribute air throughout the different areas of the home, but their performance depends greatly on how they are installed.

A flexible duct that is excessively compressed, sharply bent, or sagging increases resistance to airflow. An installation can therefore have a perfectly sized unit but insufficient airflow at the grilles.

During our work, we therefore pay particular attention:

  • to duct diameter;
  • to bend radii;
  • to their support;
  • to their length;
  • to connection tightness;
  • to insulation;
  • to network balancing.

The network must be considered an integral part of the system.

The EVOX G3 can adapt to different static pressures

The fan design is particularly interesting in a renovation context.

The technology Computational Constant Airflow 2.0 Midea’s system is designed to adjust fan power to maintain the desired airflow when network resistance varies. The manufacturer indicates control of up to 1.2 in. of water column static pressure in certain configurations.

The platform also offers up to 60 airflow adjustment levels, allowing the system’s operation to be fine-tuned according to the network and comfort requirements.

This possibility is particularly interesting when replacing an old furnace because much of the duct network often remains in place.

However, it does not replace good design.

If a duct is much too small or if return air is insufficient, we must identify the restriction rather than asking the motor to compensate indefinitely.

MERV 13 filtration available with several filter thicknesses

The EVOX G3 platform also includes a filtration module compatible with 1-, 2-, or 4-inch MERV 13, depending on the configuration selected. Midea indicates that this filtration helps capture more dust, pollen, and particles, as well as pet hair and dander.

In a home with a central system, filtration must nevertheless be selected carefully.

A more restrictive filter can increase static pressure. We must therefore look at the system as a whole: filter, return air, ductwork, fan, and required airflow.

R454B and the new generation of MIDEA central systems

The EVOX G3 presented in Midea documentation uses R454B refrigerant, classified as A2L. The manufacturer indicates a global warming potential for this refrigerant of 466.

The use of A2L refrigerants changes certain installation and service practices. Our technicians must work with the tools, methods, and procedures appropriate for the refrigerant specified by the manufacturer.

This is an increasingly important consideration when replacing older central systems in Greater Montreal.

Future accessibility is part of the installation

A furnace installed in an attic can operate for years. At some point, however, it will need to be inspected, maintained, or repaired.

On this Senneville project, we therefore had to think not only about how to install the new MIDEA EVOX G3, but also to how a technician will be able to service it later.

We particularly aim to maintain reasonable access:

  • to the service panels;
  • to the blower motor;
  • to the coil;
  • to the electric heating;
  • to the filter;
  • to the refrigerant connections;
  • to the drainage system;
  • to the electrical controls.

An extremely compact installation that blocks access to the equipment can create significant costs during future HVAC maintenance.

The controls offer several options during a renovation

Another advantage of the EVOX G3 is its control architecture.

Midea documentation indicates compatibility with communications 485 as well as with certain conventional thermostat configurations 24 V. The platform also provides various communication options between the heat pump, indoor unit, and controls.

This flexibility can be particularly useful in an existing home where running new cables between the attic, thermostat, and outdoor unit would be complex.

The final choice must, however, always be made according to the equipment actually installed and the requirements of its wiring diagram.

Mistakes to avoid when installing an electric furnace in an attic

Our experience with projects in Montréal, Laval, Longueuil, North Shore, and South Shore shows us that certain mistakes occur frequently in central-system installations in tight spaces.

Choose the capacity solely based on the old furnace

An old furnace may itself have been oversized. Copying its BTU rating is therefore not a true load calculation.

Neglect mechanical support

A horizontal unit must rest on a stable, suitable structure. Vibration, equipment weight, and service access must be considered from the outset of the installation.

Reduce the ducts excessively to facilitate connections

An overly restrictive transition can increase static pressure and reduce airflow.

Forget about future maintenance

An installation that works but has no panels that can be properly removed is poor planning.

Underestimate drainage

In an attic, condensate management is particularly critical because a leak can directly affect the ceilings of finished rooms.

Oversize the auxiliary electric heating

The EVOX G3 can receive up to 25 kW of auxiliary heating depending on the configuration, but the maximum available is not automatically the best choice.

The electrical panel and the home's actual needs must be verified before selecting the components.

Subsidies: verify the exact combination before announcing an amount

For a central heat pump, eligibility for financial assistance should never be determined solely from the commercial name “EVOX G3.”

The range includes several indoor and outdoor units. Midea's technical table also lists different model pairings and different capacities.

For a Quebec project, we must verify the exact number of the outdoor unit and the indoor unit, then compare this combination with the criteria and applicable lists for the program in effect at the time of installation.

Since the complete nameplate number cannot be read with certainty in the photograph from Senneville, we are not providing a precise subsidy amount for this project.

This is an important precaution to avoid confusing two different capacities within the same product family.

An installation where the best solution was horizontal, modular and adapted to the existing structure

This project in Senneville clearly shows what distinguishes a standard central installation from an installation requiring genuine adaptation to the building.

We were faced with an attic with:

  • a sloped roof;
  • a dense wooden frame;
  • limited height;
  • an existing duct network;
  • restricted-access areas;
  • a need to keep the equipment accessible for years to come.

The MIDEA EVOX G3 electric furnace allowed us to work with these constraints precisely because of its modular architecture and horizontal installation options.

The photo summarizes the project better than a view of a unit installed in a large, empty mechanical room: here, every orientation, clearance and connection must be carefully considered.

At AirGreen, this is the part of the work that particularly interests us. A professional HVAC installation is not about forcing a house to adapt to a machine. Instead, we seek to select and configure the equipment so that it works properly with the reality of the home.

To Senneville, as in our installations in central heat pumps and electric furnaces in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, the result depends just as much on this mechanical integration as on the performance figures listed on the technical data sheet.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment