Installation of a GREE FreeMatch R32 MultiZone Heat Pump in Rosemont–La Petite-Patrie

AirGreen installs a GREE FreeMatch R32 MultiZone heat pump in Rosemont–La Petite-Patrie: room-by-room comfort, high efficiency, clean finishes and professional HVAC maintenance throughout Greater Montreal.

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a GREE FreeMatch R32 MultiZone Heat Pump in Rosemont–La Petite-Patrie
Installation of a GREE FreeMatch R32 MultiZone Heat Pump in Rosemont–La Petite-Patrie
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

An HVAC modernization designed for four-season comfort in a typical Montreal plex

Context and objectives of the project

In a plex in Rosemont–La Petite-Patrie , our client wanted an HVAC solution capable of providing reliable heating in winter and precise cooling in summer, without invasive work. We selected a GREE MultiZone heat pump , FreeMatch R32 range , to supply several interior spaces with a single compact and quiet outdoor unit. The approach aims to:

  • room-by-room comfort (zoning);

  • substantial energy savings ;

  • discreet integration into the facades and the courtyard;

  • reliability in extreme cold typical of the Montreal climate.

Why GREE FreeMatch R32 for this plex

The FreeMatch R32 can power 2 to 5 indoor heads (wall-mounted, console, cassette), making it ideal for stacked units and typical Montreal layouts (double living room, bedrooms overlooking the courtyard, kitchen at the rear). Key benefits:

  • R-32 refrigerant : better performance potential and reduced environmental footprint compared to older generations;

  • Inverter modulation : optimized consumption, smooth starts, increased longevity;

  • Low temperature operating ranges suitable for Greater Montreal ;

  • Flexible zoning : fine distribution between living room, bedrooms and office;

  • Reduced noise level both outside and inside.

Sizing and configuration selected

After thermal readings and heat loss assessment, we program a three-zone configuration (living room, master bedroom, office) with a GREE FreeMatch R32 outdoor unit. The total capacity is distributed to avoid oversizing ; each head is adjusted to the actual load of the room. This method guarantees:

  • a long and stable operating cycle, limiting jolts;

  • regular air quality and better controlled humidity levels ;

  • more predictable energy bills .

AirGreen Tip : In MultiZone, the combined BTU output of the heads must not exceed the simultaneous capacity of the outdoor unit. Our team fine-tunes the system to combine comfort and efficiency.

Outdoor installation: winter robustness first

We install the outdoor unit on a raised galvanized steel structure with anti-vibration pads , in order to:

  • maintain clearance above the snow and promote the evacuation of frost;

  • protect the crankcase from accumulations and sludge;

  • preserve the peace of the neighborhood by reducing vibration transmissions.

The unit is positioned at a constant distance from a stone wall to comply with the clearances required for suction and front blowing. The chosen orientation facilitates:

  • service access (taps, electrical housing, filters);

  • free passage in court;

  • air circulation during defrost cycles.

The electrical connection is made via a whip in an external protective sheath, with a dedicated circuit breaker according to the equipment nameplate and the current electrical code . The refrigeration lines are continuously insulated and covered until they penetrate the casing, ensuring both aesthetics and protection against UV and shock.

Route of connections and finishes

The route of the connections is streamlined to minimize the equivalent length and pressure losses; the bends are made with a bend to preserve the integrity of the copper tubes. The holes are sealed (low expansion foam + membrane) to guarantee:

  • air and water tightness ;

  • the continuity of the vapor barrier ;

  • the absence of thermal bridges.

Gravity-based condensate management is preferred when the natural slope allows it; failing this, we integrate a low-noise lifting pump with an accessible maintenance tank.

Commissioning: rigor and traceability

Our AirGreen protocol includes:

  1. Nitrogen test and pressure-stabilized leak test ;

  2. Deep vacuum draw , followed by a lift test ;

  3. Charge opening and subcooling/superheat check ;

  4. Electrical control (continuity, tightening, intensities);

  5. Configuration of indoor units (ventilation, shutters, recording of optimal settings);

  6. Customer training : daily use, winter/summer instructions, filter maintenance.

Each step is recorded in a commissioning sheet , useful for warranty and monitoring.

Result: controlled comfort, preserved facade

The facade and access points are preserved thanks to discreet capping and the thoughtful installation near the fence . The compact, vertical outdoor unit with a double fan offers an excellent power/size ratio , perfect for the narrow courtyards so common in Montreal. The user benefits from:

  • stable heating down to the usual negative temperatures;

  • targeted refreshing in living areas;

  • a significant reduction in the bill compared to independent electric convectors.

HVAC Maintenance: Maintaining Performance

Regular HVAC maintenance is crucial to maintaining performance:

  • Cleaning and vacuuming of the head filters (every 4 to 8 weeks in season);

  • Annual inspection by our technicians: coil, fans, connections, vacuum gauge, measured loads;

  • Winter check : clear snow around the unit, approximately 30 to 60 cm on all sides;

  • Control of supports , leveling and condensate flow .

Winter Tip : Maintain clearance under the unit and do not block the front airflow. Avoid direct snow guards that could recirculate air; we offer specially designed deflectors if needed.

Grants and Compliance

High-efficiency R-32 heat pumps may be eligible for financial assistance programs when performance and installation criteria are met. We support our clients in:

  • eligibility verification ;

  • preparation of documents (detailed estimate, site photos, serial numbers);

  • submission of requests and follow-up until payment.

What this installation changes on a daily basis

  • Uniform temperature from the living room to the bedrooms;

  • Rapid response to mid-season weather variations;

  • Silence and nighttime comfort thanks to low noise modes;

  • Simple control : remote controls, time programming, Wi-Fi integrations available depending on the heads chosen.

The AirGreen “pluses” on this project

  • Room-by-room load study , no guesswork;

  • Care of finishes (hoods, seals, alignments) for clean integration ;

  • Instrumented commissioning and reference photo file ;

  • Priority assistance and maintenance in Montreal, Laval , Longueuil , North Shore and South Shore .

Points of attention to remember for your project

  • Proper sizing takes precedence over the “size” displayed in BTUs;

  • Clearances around the outdoor unit are non-negotiable;

  • Annual maintenance prevents performance losses and extends lifespan;

  • Careful routing of refrigeration lines determines overall reliability .

Conclusion

This MultiZone GREE FreeMatch R32 heat pump installation in Rosemont–La Petite-Patrie illustrates our approach: pragmatic engineering , clean finishes , and comprehensive support—from equipment selection to commissioning and maintenance . For a sustainable and efficient HVAC project in Greater Montreal , AirGreen remains your trusted partner.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment