Installation of a Gree wall-mounted heat pump in Duvernay, Laval

AirGreen installs a Gree Inverter wall-mounted heat pump in Duvernay, Laval. Professional HVAC installation with optimal performance and access to grants.

By AirGreen Climatisation & Chauffage Admin2 min read
Installation of a Gree wall-mounted heat pump in Duvernay, Laval
Installation of a Gree wall-mounted heat pump in Duvernay, Laval
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

An installation optimized for lasting comfort

At AirGreen , we understand that every wall-mounted heat pump installation project requires a tailored approach. In Duvernay, a residential area of ​​Laval known for its spacious, family-friendly homes, our team recently installed a Gree Inverter heat pump , a powerful and reliable solution for year-round comfort.

Why the Gree heat pump?

Gree wall-mounted heat pumps are distinguished by their energy efficiency and their ability to maintain stable performance even during harsh Quebec winters. This unit from the Inverter range, with a high-efficiency compressor, is designed for:

  • Provide efficient heating down to -25°C, ideal for Laval, Montreal, the North Shore and the South Shore.

  • Reduce energy consumption through intelligent compressor modulation.

  • Guaranteeing quiet operation, perfect for residential areas like Duvernay.

Key steps in setting up in Duvernay

Preparation and strategic location

The outdoor condenser was mounted on a raised metal support, protecting the unit from snow accumulation and ensuring optimal ventilation. The installation on the side of the house provided perfect accessibility for the electrical and refrigerant connections.

Commissioning and calibration

Our technicians used a digital manifold to monitor pressure and a vacuum pump to remove moisture from the refrigerant lines before charging the system. This step is crucial to ensure compressor longevity and prevent any issues related to internal contamination.

Visible technical details

  • R-410A refrigerant cylinder connected for precise charge adjustment.

  • Electrical wiring connected directly to a wall-mounted disconnect box, ensuring compliance with local electrical standards.

  • Specialized tools (pump, cordless drill, wrenches) used for precise and safe work.

  • Discreet insulation and capping to protect refrigerant lines and provide an aesthetic finish.

Customer Benefits

Thanks to this installation, occupants now benefit from:

  • 4-season comfort , with reliable heating in winter and efficient air conditioning in summer.

  • Reduced energy costs thanks to the higher efficiency of inverter technology.

  • Peace of mind with an AirGreen certified installation backed by a full warranty.

Available Grants and Programs

This Gree heat pump is eligible for provincial and federal grant programs such as LogisVert and the Canadian Greener Homes program, allowing customers to significantly reduce their acquisition costs.

AirGreen Expertise: The Difference

Through this project in Duvernay, Laval , AirGreen once again demonstrates its expertise in HVAC installation . Our certified technicians not only respect safety and efficiency standards, but they also take care of every detail to ensure long-lasting performance and impeccable aesthetics.

Whether you are in Montreal, Laval, Longueuil, on the North Shore or the South Shore , we will assist you in the choice, installation and maintenance of your HVAC equipment in order to maximize your comfort and energy savings.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment