Installation of a Gree wall-mounted heat pump in Rosemont–La Petite-Patrie

AirGreen installs a Gree R-32 wall-mounted heat pump in Rosemont–La Petite-Patrie: short rear opening, gravity drain, discreet finish and high efficiency. Professional HVAC installation for Montreal, Laval, Longueuil, North Shore and South Shore.

By AirGreen Climatisation & Chauffage Admin7 min read
Installation of a Gree wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of a Gree wall-mounted heat pump in Rosemont–La Petite-Patrie
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Project context and comfort objectives

In a typical Rosemont–La Petite-Patrie apartment, our client wanted to improve the comfort of the living areas while limiting the visual impact of the equipment. We proposed a latest-generation Gree wall-mounted heat pump with R-32 refrigerant , sized to quickly cool during heat waves and efficiently heat during the inter-seasons. The specifications: low noise, even air diffusion in the open area, clean and fast HVAC installation , and simplified maintenance.

Choosing an interior location: height, airflow, access

The interior head is placed high up, on the ceiling side , a few centimeters from a wall corner and close to a patio door. This position has several advantages:

  • Optimized air diffusion : the motorized shutter sends the flow along the ceiling to mix the air without direct air currents on the occupants.

  • Easy access for HVAC maintenance : the front cover opens wide for cleaning the filters and evaporator.

  • Neat aesthetics : compact white case, perfectly aligned, without protrusions or visible accessories.

We always recommend avoiding obstacles (thick curtains, ceiling drops, columns) within 1 m of the blower. Here, the volume is clear, ideal for the wall-mounted heat pump .

Technical route: short drilling, gravity drain and protected refrigeration lines

In this courtyard-side brick plex, we are making a direct hole at the back of the head . Key points:

  • Refrigeration lines : ultra-short path to the outside, reducing pressure losses and improving seasonal efficiency.

  • Gravity condensates : continuous slope towards the outside, which avoids the use of a pump and therefore reduces noise, maintenance and risk of breakdown.

  • Minimal capping : no visible ducting inside; outside, the connections are sheathed and insulated , fixed properly and sealed around the perimeter of the hole (mastic + weatherstripping).

This type of configuration is exemplary for Montreal apartments overlooking a brick courtyard: discreet, efficient and durable.

Power supply and compliance

We install a dedicated circuit breaker for the panel, wiring that complies with the Quebec Electrical Code , and an external disconnect switch near the condenser (out of view in the photo). Our AirGreen teams are trained in RBQ requirements and good sealing and electrical safety practices. The result: a safe system, well protected against the elements and easy to isolate during maintenance.

Why Gree at R-32 for this project

The Gree brand is known for its quiet wall-mounted heads, fine modulation of inverter compressor, and a wide R-32 range (Vita, Clivia, Airy, Vireo, etc.). Without imposing a reference when the label is not visible, we are choosing here a Gree R-32 wall-mounted model with the following characteristics:

  • High seasonal efficiency (SEER/SCOP competitive) thanks to R-32 refrigerant and modulation.

  • Reduced noise : very quiet low-speed operation, ideal for bedrooms/living rooms.

  • Useful low-temperature heating : reliable performance up to the usual Montreal off-season cold.

  • Washable filters and quick access to components for HVAC maintenance .

In practice, this combination provides an excellent comfort/consumption ratio in an average-sized urban dwelling.

Sizing and result obtained

We size each heat pump according to:

  • the usable surface area and the free height,

  • the orientation of the glazing and the sunlight,

  • insulation (brick walls, windows),

  • the open plan layout.

Here, the sensible air conditioning load is moderate and the need for supplementary heating in the off-season is a priority. The choice of an R-32 wall unit is the perfect solution: rapid increase in comfort in summer, stable and economical maintenance in spring/autumn, with contained electricity consumption .

Installation details taken care of by AirGreen

  • External support (not visible) placed on galvanized brackets or slab depending on the facade constraints.

  • Controlled vibrations : anti-vibration pads and controlled tightening torque.

  • Waterproofing : cable glands, butyl tapes and mastic to protect the building envelope.

  • Testing and commissioning : vacuum drawing, leak testing, refrigerant charger checked, and verification of blowing temperatures .

  • Finish : aligned wiring and insulation, UV fasteners, straight and discreet exterior trunking .

Usage tips to maximize comfort

  • Auto/Heat/Cool mode : favor a stable mode rather than frequent back and forth, in order to exploit the inverter modulation.

  • Reasonable guideline : in summer, aim for 23–24°C; in winter, 21–22°C depending on how you feel.

  • Shutter : point slightly towards the ceiling to promote air mixing and avoid direct airflow.

  • Open doors : in an open area, leave the circulation areas clear to distribute air to adjacent rooms.

HVAC Maintenance: Simple but Essential

Annual maintenance preserves performance and longevity:

  • Clean filters every 4–6 weeks during peak season.

  • Inspection of the evaporator and fan, disinfection of the condensate tray.

  • Checking the disconnector , line insulation and gravity drainage.

  • Check the outdoor condenser: fins clean, clear of leaves/snow, free space at the outlet.

AirGreen offers maintenance plans tailored to residences in Montreal, Laval, Longueuil, North Shore and South Shore .

Grants and energy compliance

Well-rated R-32 wall-mounted heat pumps may be eligible for certain support programs when performance and installation criteria are met. We guide you through the selection of certified models , required documentation, and up-to-date procedures for homeowners in the greater Montreal area.

What the installation changes for the customer's daily life

  • Immediate comfort in the open area, without over-air conditioning.

  • Quiet : At night, the unit operates at an imperceptible low speed.

  • Bills under control : modulation avoids consumption peaks.

  • Aesthetics : the Gree unit blends into the decor, with no visible cable ducts inside.

Why entrust your project to AirGreen?

At AirGreen , we deliver HVAC systems tailored to Montreal architecture: plexes, condos, townhouses. Our teams:

  • evaluate the thermal load and the blowing strategy ,

  • plan short routes (better efficiency ),

  • work cleanly and quickly ,

  • provide responsive after-sales service (maintenance, diagnostics, parts).

Whether you are in Montreal , Laval , Longueuil , on the North Shore or the South Shore , we understand local constraints (brick facades, walkways, alleys, flat roofs) and deliver durable systems.

Technical points to remember

  • Type : Gree R-32 wall-mounted heat pump .

  • Installation : head high up near the ceiling, direct rear drilling, gravity drain .

  • Benefits : high seasonal efficiency, low noise, easy maintenance, sleek aesthetics.

  • Best practices : short lines, careful sealing, external disconnector, vacuum test and temperature checks.


Are you considering a wall-mounted heat pump for your home in Rosemont , Villeray , Hochelaga , Laval , or the South Shore ? AirGreen can help you with advice , installation , maintenance , and grant monitoring. Let's discuss your project and find the most efficient configuration for your space.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).