Project

Installation of a Haxxair central heat pump in Terrebonne

Installation of a central Haxxair heat pump in Terrebonne by AirGreen. The project was installed on a flat roof with custom-designed supports, providing optimal performance and eligibility for HVAC subsidies.

By AirGreen Climatisation & Chauffage Admin3 min read
Installation of a Haxxair central heat pump in Terrebonne
Installation of a Haxxair central heat pump in Terrebonne
–chapters in this story
3 minreading time
–type of installation
2025year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

The job

A flat roof installation project in a residential area of ​​Terrebonne

At AirGreen , we are regularly called upon to intervene in a variety of contexts, ranging from the installation of wall-mounted units in condominiums to the installation of central heat pumps on flat roofs. Recently, our team completed the installation of a Haxxair heat pump in a residential neighborhood in Terrebonne , on the North Shore of Montreal. This type of configuration requires meticulous preparation and specific adjustments, since the condenser must be positioned stably and securely on a roof.

Installation preparation and configuration

From the moment we arrived on site, our priority was to ensure the stability of the outdoor condenser . We installed the Haxxair unit on treated wooden supports , suitable for flat roofs. This method avoids any direct contact with the roof surface and ensures better weight distribution.

The presence of exposed electrical wiring and piping also required careful planning. Our team chose an optimized route for the refrigerant connections, limiting energy losses and facilitating future maintenance.

Technical features of the Haxxair heat pump

The installed Haxxair heat pump is designed to provide four-season comfort in the Quebec climate. With high energy efficiency (Energy Star) and stable performance down to -25°C , it is eligible for grant programs available in Quebec, particularly on the North Shore, Laval, Longueuil and Montreal .

Features highlighted during this installation:

  • Inverter technology for precise power adjustment.

  • High efficiency compressor for reduced power consumption.

  • Heating and air conditioning capacity suitable for single-family homes in the Terrebonne region.

Challenges encountered and solutions provided

The main challenge of this project was the installation on a flat roof , where weather conditions (wind, rain, temperature variations) can accelerate the wear of the material. To address this, we integrated:

  • Raised supports to protect the device from stagnant moisture.

  • A specific orientation of the unit to maximize air circulation.

  • Connections protected by high-density insulation, guaranteeing optimal resistance to the harsh winters of the North Shore.

Customer Benefits

Thanks to this installation, the owner now benefits from a system:

  • Efficient in heating and cooling all year round.

  • Eligible for grants that significantly reduce investment costs.

  • Easy to maintain , since the pipe route and technical access have been designed for rapid interventions.

In addition, by choosing AirGreen, the customer benefits from comprehensive support, including advice on available subsidies, commissioning by certified technicians and post-installation monitoring.

Conclusion: know-how adapted to local realities

Every central heat pump installation in Terrebonne is unique, and our experience allows us to adapt to all configurations. Whether on a flat roof, in a garage, or in a backyard, we always strive to offer a reliable, aesthetically pleasing, and durable solution. At AirGreen, we combine our technical expertise with in-depth knowledge of Greater Montreal's energy needs to ensure our customers optimal comfort, summer and winter.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment