Job sheet · Project

Installation of an LG Dual Inverter wall-mounted heat pump in Rosemont–La Petite-Patrie

AirGreen installed an LG Dual Inverter wall-mounted heat pump in a kitchen in Rosemont–La Petite-Patrie, optimizing HVAC comfort and energy savings for residents of Greater Montreal.

By AirGreen Climatisation & Chauffage Admin4 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
4 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of an LG Dual Inverter wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of an LG Dual Inverter wall-mounted heat pump in Rosemont–La Petite-Patrie
The full story

The article, chapter by chapter

Modern comfort in the heart of Montreal cuisine

At AirGreen , we transform each HVAC installation into a personalized solution, adapted to the architecture and lifestyle of Greater Montreal residents. Recently, our team installed an LG Dual Inverter wall-mounted heat pump in a duplex kitchen located in Rosemont–La Petite-Patrie . The goal: to provide stable thermal comfort while respecting the space constraints of a room where every inch counts.


Context of the project in Rosemont

The owner of a typical duplex in the area contacted us to upgrade his HVAC system. The space to be air conditioned and heated was located in the kitchen, an environment where heat and humidity can quickly become uncomfortable.

The old portable air conditioner consumed too much energy and didn't provide effective temperature regulation. Choosing an LG wall-mounted heat pump was therefore an ideal solution: small footprint, high energy efficiency, and quiet operation.


Technical specifications of the LG Dual Inverter

  • Type : Wall-mounted heat pump (mini-split)

  • Brand : LG

  • Model : Dual Inverter (Energy Star certified range)

  • Capacity : 9,000 BTU (enough for a kitchen and adjoining space of 350 to 400 sq. ft.)

  • Performance : High SEER2, HSPF2 optimized for Quebec winters

  • Key technology : Dual Inverter compressor providing quieter operation and reduced energy consumption


Installation process

Main steps

  1. Assessment and preparation : We chose a high location, above the kitchen cabinets, to free up wall space and optimize air circulation.

  2. Wall drilling : discreet passage of refrigerant connections and electrical wiring to the outside, with white capping to match the walls.

  3. Indoor Unit Mounting : LG wall head installation with precise clearance to avoid interference with cabinets.

  4. Connection to the external compressor : positioned on a wall bracket at the rear of the duplex to limit noise pollution and ensure good condensate drainage.

  5. Calibration and testing : pressure verification, gravity drainage control and complete performance testing.

Constraints encountered and solutions

  • Proximity to cabinets : The unit had to be installed directly above tall cabinets, requiring increased precision to ensure easy access to the front panel and optimal airflow clearance.

  • Condensate management : the limited space required carefully planned gravity drainage to avoid any accumulation of water near kitchen units.


Results for the client

The owner now benefits from:

  • Stable thermal comfort in summer and winter.

  • A quiet appliance, ideal for family cooking.

  • A significant reduction in the electricity bill , thanks to Inverter technology.

  • An aesthetic solution , perfectly integrated into a restricted space.

In addition, the LG Dual Inverter model is eligible for local subsidies (Montreal, Laval, Longueuil, North Shore, South Shore), which further reduces the net cost of the project.


Maintenance and durability

To maximize the life of your LG heat pump:

  • Filters should be cleaned every 2 to 3 months , especially in a kitchen where the air contains more particles.

  • A complete annual maintenance by AirGreen is recommended: checking the outdoor compressor, cleaning the coils, inspecting the refrigerant and calibrating the system.


Why entrust your HVAC installation to AirGreen?

  • Local expertise : regular installations in Rosemont, Plateau, Hochelaga and throughout Montreal.

  • Complete service : advice on choosing the model, professional installation and support with grant applications.

  • Quality guarantee : compliance with RBQ standards and optimization of energy performance.

  • Customer satisfaction : comfort, savings and peace of mind guaranteed.


Conclusion

This installation in Rosemont–La Petite-Patrie illustrates AirGreen's ability to adapt LG Dual Inverter technology to the real-world constraints of a Montreal home . The wall-mounted heat pump offers an ideal compromise between performance, compact design, and energy savings.

At AirGreen, we are committed to improving the comfort of homes in Montreal, Laval, Longueuil, the North Shore and the South Shore , one project at a time.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment