Installation of a Midea28 wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of a Midea28 wall-mounted heat pump in Rosemont–La Petite-Patrie
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea Série 28 9 00012,00011,500−30 °C: 5,1001.827.412.5–
Midea Série 28 12 00012,00011,500−30 °C: 5,9001.825.410.5$1,440
Midea Série 28 18 00018,00018,000−30 °C: 8,0001.9221.411.0$2,160
Midea Série 28 24 00022,20024,200−30 °C: 11,9002.3421.013.5$2,664
Midea Série 28 33 00032,00035,000−30 °C: 20,7001.9819.510.5$3,840
12,000Its full nominal heating at −8 °C

According to NEEP, it delivers 12,000 BTU/h at −8 °C (17 °F), as much as at 8 °C. It heats as hard in moderate cold as in mild weather.

16,000A 16,000 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 16,000 BTU/h, 33% more than its nominal 12,000 BTU size.

2,000It modulates down to 2,000 BTU/h

At −30 °C, its certified minimum capacity is 2,000 BTU/h (3,800 at 8 °C). It slows down instead of cycling on and off.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.A dash in the aid column: amount to be confirmed for this model.

The full story

The article, chapter by chapter

A sleek Midea28 heat pump installation in a Montreal hallway

At AirGreen , we know that every corner of a Montreal home can be optimized for maximum thermal comfort, without compromising aesthetics or space. This installation of a Midea28 wall-mounted heat pump in a typical Rosemont–La Petite-Patrie vestibule perfectly illustrates our expertise: efficiency, precision, and harmonious integration into the residential environment.

A compact vestibule, an engineering challenge mastered

The entrance hall of this residence, with its oval-patterned glass door and low ceiling , left little room for the installation of a wall-mounted unit. However, our team was able to optimally position the Midea28 indoor head, just above the door , ensuring even air distribution in the hallway and adjacent rooms.

The limited space required the use of a low-clearance stepladder and precise routing of the wiring to the side wall leading outside. Thanks to our experience with older Montreal buildings, we anticipated structural and clearance constraints.

The choice of the Midea28: performance and silence

The Midea28 is a new generation wall-mounted heat pump with R-454B refrigerant , designed to deliver high performance while reducing environmental impact. Its operation down to −30°C makes it a top choice for Montreal's harsh winters.

Its main advantages:

  • High-efficiency inverter technology allowing fine modulation of power.

  • Ultra-low noise level (indoor < 21 dB), perfect for passageways.

  • 4-season heating and cooling capacity , with integrated dehumidification.

  • Compatibility with Quebec grant programs for Energy Star systems.

Aesthetic integration and discreet refrigerant path

In this project, the client wanted to avoid any visible trunking in the vestibule. We therefore opted for a hidden side passage , with capping matching the exterior color of the wall.
The refrigerant pipe route has been carefully planned:

  1. Wall outlet behind the side partition,

  2. Direct crossing to the outside,

  3. Condenser installed on wall brackets to preserve the floor space of the balcony.

This minimal path reduces heat loss and optimizes system efficiency, while preserving interior aesthetics.

Immediate and uniform thermal comfort

Once put into service, the Midea28 quickly demonstrated its capabilities:

  • Stable and even heating from the first minutes.

  • Intelligent regulation thanks to the wall sensor and programmable thermostat.

  • Adjustable airflow to direct heat to the hallway or living room.

This installation eliminated the temperature variations often experienced in Montreal entrances and stairwells.

Safety, efficiency and simplified maintenance

Our certified technicians performed a complete leak test of the refrigerant lines, verified the gravity drainage of the condensate , and calibrated the airflow for optimal performance.
The customer now benefits from a guaranteed, reliable and economical system , requiring only annual maintenance to maintain its performance.

A typical project from our work in Montreal

This type of installation perfectly illustrates the versatility of our AirGreen team . We operate in all boroughs of Montreal, Laval, the South Shore and the North Shore, adapting each project to local architectural realities—whether it involves older plexes, renovated condos, or single-family homes .

The Midea28, with its balance of compactness, performance and durability, meets the needs of many urban households looking for a modern, quiet and energy-efficient HVAC solution .

Why choose AirGreen for your Midea heat pump installation in Montreal

By entrusting your project to AirGreen, you benefit from:

  • Recognized expertise in the installation of Midea, Gree, Sharp and Fujitsu wall-mounted heat pumps.

  • A turnkey service , including needs assessment, professional installation and grant procedures.

  • Personalized follow-up after installation to guarantee the longevity and performance of your system.

Every detail counts—orientation, height, clearance, condensate drainage—and it is this rigor that makes the difference between a standard installation and an AirGreen installation.

In summary

This Midea28 wall-mounted heat pump installation in Rosemont–La Petite-Patrie demonstrates that a cramped entryway can become a space of optimal thermal comfort thanks to careful planning and proven expertise. At AirGreen, we transform every constraint into an opportunity for innovation, serving the sustainable comfort of Montrealers.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment