Project

Installation of a Fujitsu wall-mounted heat pump in Fabreville (Laval)

In Fabreville, AirGreen installed a Fujitsu AIRSTAGE R-32 wall-mounted heat pump near a residential garage: an efficient, clean and durable solution for comfort in summer and winter.

By AirGreen Climatisation & Chauffage Admin5 min read
Installation of a Fujitsu wall-mounted heat pump in Fabreville (Laval)
Installation of a Fujitsu wall-mounted heat pump in Fabreville (Laval)
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

In Fabreville , a well-established residential area of ​​Laval, thermal comfort must adapt to very realities: single-family homes with garages, adjacent utility spaces, significant temperature variations, and harsh winters. At AirGreen , we recently completed the installation of a Fujitsu wall-mounted heat pump in this specific context, with particular attention paid to durability, winter protection, and seamless system integration.

Project context: targeted comfort and discreet integration

The client wanted to improve the comfort of a key area of ​​the house while maintaining a discreet and protected outdoor installation near the garage. The challenge was not just to install the equipment, but to do so logically:

  • Exterior wall adjacent to a residential garage

  • The presence of eaves and soffits must be taken into account.

  • The need to protect conduits and cables

  • Easy access for maintenance, without disrupting the daily use of the garage

The chosen solution: a Fujitsu wall-mounted heat pump , AIRSTAGE range, using R-32 refrigerant, known for its reliability and performance in Quebec climate.

Machine type: wall-mounted heat pump (mini-split)

The visual clues are clear: compact Fujitsu outdoor unit, refrigerant lines protected by a vertical cover line , dedicated power supply and typical configuration of a wall-mounted mini-split system .
This type of heat pump is perfectly suited to homes in Fabreville:

  • No major modifications to existing conduits

  • Quick and targeted installation

  • Excellent energy efficiency

  • Heating and air conditioning in the same system

The brand: Fujitsu , proven reliability in Quebec

The brand supplied is Fujitsu , and this choice is a natural one for residential applications in Greater Montreal. Fujitsu AIRSTAGE systems are known for:

  • Their stable inverter technology

  • Precise temperature regulation

  • Quiet operation

  • High reliability over several years

The R-32 refrigerant, visible on the unit, confirms that it is a recent generation, more efficient and better suited to current standards.

Model: Fujitsu AIRSTAGE R-32 – Altair series (consistent)

Even though the exact nameplate is not legible in the photo, the whole thing clearly corresponds to a Fujitsu AIRSTAGE R-32 wall-mounted heat pump , of the Altair type (e.g. Altair 300 or 500 depending on the installed capacity).
At AirGreen, we always favour sizing that is consistent with the actual needs of the building, rather than unnecessary oversizing.

Prominent installation details observable

This installation highlights several essential best practices, especially in a residential setting in Laval.

1) Rigid and waterproof vertical cover

The refrigeration lines and wiring are protected by a white cover plate , securely fixed to the wall. This allows:

  • Protection against moisture and frost

  • A clean and durable finish

  • An aesthetically pleasing integration near the garage

2) Strategic positioning under the eaves

The outdoor unit is installed in an area partially protected by the building structure. This location reduces direct exposure to snow and rain, while maintaining the clearances required for air circulation.

3) Easy access for maintenance

Positioning near the garage allows easy access for inspections and seasonal maintenance, without compromising the use of outdoor spaces.

4) Careful fixing to residential surface

The anchoring is clean, straight and adapted to the type of wall, limiting vibrations and ensuring long-term stability — a crucial point for acoustic comfort.

Comfort and performance for everyday use

A properly installed Fujitsu AIRSTAGE R-32 wall-mounted heat pump offers:

  • Effective cooling during Laval's hot summers

  • Reliable heating during the shoulder seasons

  • A stable temperature, without sudden fluctuations

  • Its discreet operation is appreciated in quiet residential areas.

For a house in Fabreville, this is an ideal solution to improve comfort without invasive work.

The AirGreen approach applied to this project

Each installation follows a rigorous method:

  • Analysis of the building and the areas to be served

  • Choosing the optimal location for the outdoor unit

  • Duct protection and meticulous finishing

  • Complete verification during commissioning

  • Installation designed for Quebec winters

It is this attention to detail that guarantees longevity and customer satisfaction.

Common mistakes avoided

In several comparable projects, we often make corrections to:

  • Unprotected exposed conduits

  • Units poorly positioned in the face of the snow

  • Rough fixings

  • Noisy or poorly ventilated facilities

Here, every decision was made to ensure a sustainable and consistent result.

Why this installation is typical of Fabreville

Fabreville combines single-family homes, attached garages, and utility spaces. A Fujitsu wall-mounted heat pump perfectly meets this need: flexible, efficient, and easy to integrate.
At AirGreen , we carry out this type of installation throughout Laval, Montreal, the North Shore and the South Shore, with the same high standards of quality.

In summary

This installation in Fabreville (Laval) demonstrates how a Fujitsu AIRSTAGE R-32 wall-mounted heat pump , properly positioned and protected, can provide optimal comfort year-round. A reliable, discreet solution perfectly suited to Quebec residential properties.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment