Job sheet · Project

Installation of a Sharp Eco Inverter wall-mounted heat pump in Parc-Extension

Installation of a Sharp Eco Inverter wall-mounted heat pump in Parc-Extension: ceiling head on the landing, optimized air circulation, gravity evacuation and high efficiency. AirGreen: Careful HVAC installation in Montreal, Laval, Longueuil, North Shore, South Shore.

By AirGreen Climatisation & Chauffage Admin7 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
7 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp Eco Inverter wall-mounted heat pump in Parc-Extension
Installation of a Sharp Eco Inverter wall-mounted heat pump in Parc-Extension
The full story

The article, chapter by chapter

Multi-level comfort, careful installation and optimized air circulation in the heart of a Montreal plex

In a Parc-Extension plex, our team installed a Sharp Eco Inverter wall-mounted heat pump judiciously placed on the wall of the main landing, above the stair railing. This strategic positioning allows for powering both the ground floor living area and the upper floor, while keeping the equipment discreet and easily accessible for maintenance. The objective set with the owner: four-season thermal stability , silence , low consumption and aesthetic integration within the interior of a typical Montreal home.

Why a wall-mounted headboard on the landing changes the comfort of a plex

In Greater Montreal's plexes, staircases create a veritable thermal chimney : hot air rises naturally, cool air descends. By installing the interior header on the landing, we harness this dynamic to:

  • quickly diffuse the cold to the upper rooms in summer and bring the coolness back down without aggressive drafts;

  • stabilize the heating in mid-season, the temperate air being distributed better between the levels;

  • avoid dead zones often encountered when the unit is confined to a corner of the living room.

Motorized shutters direct airflow along the corridor axis and toward the staircase. Moderate fan speed limits noise while generating gentle, even airflow. The result: consistent comfort and longer cycles, resulting in better seasonal efficiency (SEER2/HSPF2).

The safe bet of a Sharp Eco Inverter for Montreal

The Sharp Eco Inverter wall-mounted range is particularly well suited to the needs of urban housing:

  • Fine modulation inverter compressor : reduced consumption and precise maintenance of the setpoint;

  • Air quality technology (Plasmacluster type ionicity depending on the series) appreciated in high occupancy housing;

  • Low noise levels inside and outside, essential in adjoining buildings;

  • Efficient defrost management for Montreal 's cold periods, with low temperature capacity maintenance according to sizing.

For an average plex, a range of 9,000 to 18,000 BTU covers most scenarios. We always size based on the actual heat load (orientation, insulation, inertia, internal inputs) to avoid oversizing and short cycles .

Technical course: clean, short and designed to last

The installation follows a short path logic between the indoor unit and the outdoor unit, in order to:

  • reduce pressure losses on copper connections;

  • improve system responsiveness ;

  • limit the visual footprint both inside and outside.

Our key steps:

  • Controlled drilling with watertight wall pass-through and careful insulation;

  • Nitrogen brazing of the connections to avoid internal oxidation;

  • Nitrogen pressure test then deep vacuum (< 500 microns) until stabilization;

  • Load balance based on actual length, with recording of values.

Condensate is drained by gravity to the outside, simplifying maintenance and eliminating the risk of pump noise. The dedicated power supply and external disconnect near the condenser ensure safety and ease of service.

Interior integration: performance without visual compromise

The unit is installed under the ceiling , perfectly level, away from lateral obstacles to allow the suction to breathe . This height:

  • maximizes useful stratification in air conditioning;

  • frees up circulation and preserves the aesthetics of the stairwell;

  • allows quick access for cleaning filters .

The controller is set for a gradual temperature ramp , avoiding sudden variations. The shutters are programmed so that the flow follows the axis of the staircase, then distributes itself in the upstairs corridor. The flow settings are recorded in our commissioning sheet to facilitate maintenance visits.

Acoustics and vibrations: total discretion

In a staircase, the slightest vibration can be transmitted to the structure. We control this by:

  • fixing the back plate to a load-bearing area and respecting the tightening torques;

  • checking for the absence of resonance after switching on, with the shutters open/closed;

  • ensuring that the blowing does not directly hit the railing or a nearby wall, which would cause whistling .

These precautions ensure discreet operation in traffic, even at night.

Electrical Safety and HVAC Compliance

Each AirGreen installation follows good HVAC practices:

  • Dedicated circuit breaker for the main panel;

  • Protected communication cable and discreet routing;

  • Validated grounding and watertight connections ;

  • Complete documentation for the manufacturer's warranty and for possible subsidies .

We provide the customer with the commissioning sheet (vacuum values, pressures, blowing/return temperatures, operating intensity) as well as our operating advice .

HVAC Maintenance: Maintaining Performance Throughout the Seasons

To maintain performance and air quality :

  • Rinse filters every 4 to 8 weeks during periods of heavy use;

  • Dust the outdoor heat exchanger in spring and fall;

  • Check the condition of the external insulation , the silent blocks and the tightness of the terminal blocks every year;

  • Schedule HVAC maintenance by our technicians before summer and before winter (pressure, temperature, defrosting, and connection checks).

Regular maintenance extends the life of the compressor, keeps consumption low and ensures healthier indoor air.

Tips for using a multi-story home

  • Realistic instructions : in air conditioning, a setpoint around 23–24°C maintains comfort and sobriety; in heating, favor gentle modulation .

  • Fan mode : during heat waves, leaving the ventilation on low continuously promotes circulation between levels.

  • Doors : Keep circulation doors half-open to aid diffusion, especially in the evening.

  • Sensors : avoid placing an additional probe or thermostat in a draft or opposite the ramp.

Common pitfalls avoided by our method

  1. Unit too low , blowing directly onto the occupants of the landing: installation under the ceiling avoids discomfort.

  2. Unnecessarily long connection routes : pressure losses and noise - we optimize the route .

  3. Condensate pump installed by default: maintenance source — gravity drainage is preferred.

  4. Rough tightening : vibration risks — torque-controlled and systematic resonance control.

  5. Neglected settings : short cycles — logged fan and shutter settings .

Grants and support

Depending on the performance selected (certified yields, maintenance of low-temperature heating capacity), the installation of a heat pump may be eligible for assistance programs. We support households in Montreal , Laval , Longueuil , the North Shore and the South Shore in verifying criteria , collecting evidence (serial numbers, installation photos, detailed invoice) and submitting files. Our goal: to maximize financial assistance when conditions are right.

What the owner of Parc-Extension remembers

  • Uniform comfort on both levels, without unpleasant drafts;

  • Silence in the stairwell and adjacent rooms;

  • Controlled energy bills thanks to inverter modulation;

  • Aesthetic integration : no visible chute in the circulation areas, discreet passage to the exterior;

  • Simple maintenance : accessible filters and gravity condensate drainage.

Our commitment at AirGreen: to propose and install HVAC solutions adapted to local architecture, with clean, measurable and sustainable execution . From Montreal to Laval , from Longueuil to the North Shore and the South Shore , we deploy the same rigorous method: precise sizing , careful implementation , documented commissioning , and ongoing maintenance .

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment