Project

Installation of a Sharp wall-mounted heat pump in Rosemont

AirGreen installs a Sharp wall-mounted heat pump in Rosemont. An HVAC project optimized for the limited space of a Montreal duplex, offering comfort, energy savings, and subsidies.

By AirGreen Climatisation & Chauffage Admin3 min read
Installation of a Sharp wall-mounted heat pump in Rosemont
Installation of a Sharp wall-mounted heat pump in Rosemont
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

A discreet and efficient HVAC solution for a Montreal duplex

At AirGreen , we regularly work in typical Montreal buildings where space is limited and every detail counts. In this project in the Rosemont district, we installed a Sharp wall-mounted heat pump , perfectly suited to the constraints of an urban duplex with a narrow entrance and a bright stairwell.

Project background

The client wanted to modernize their heating and air conditioning system to improve the comfort of their home while taking advantage of the subsidies available in Quebec . The main challenge was the limited space near the entrance: the indoor unit had to be integrated high up, without hindering traffic flow or aesthetics.

Choice of equipment: Sharp, a guarantee of reliability

The Sharp wall-mounted heat pump is one of the most popular models for its reliability and performance in cold climates. Capable of operating efficiently down to -25°C, it perfectly meets the needs of Montreal homes. Its inverter technology helps maintain a stable temperature while reducing energy consumption.

Among the advantages:

  • High energy efficiency with excellent SEER2/HSPF2.

  • Quiet operation , ideal for apartments.

  • Compact and modern design , discreet in a narrow corridor.

  • Compatibility with provincial and federal grant programs .

Installation process

Our technicians began by attaching the wall-mounted fan head above the front door. This strategic positioning allows for even air distribution while freeing up floor space. The installation height required the use of a professional stepladder and precision tools to ensure perfect alignment.

  • Discreet drilling of the exterior wall for the passage of refrigeration connections.

  • Wiring and piping routed neatly along the wall with matching white capping.

  • Gravity connection of the condensate drain , thus avoiding the addition of a pump and simplifying future maintenance.

  • Complete commissioning tests : leak-tightness of connections, vacuum, pressure verification and electronic calibration.

Technical constraints and solutions

The main challenge was the very limited space in the entrance. Our installers chose a high-mounted installation to avoid any obstruction of the door and optimize air circulation. In addition, special care was taken to route the pipes so that they remained invisible from the main room.

Result and benefits for the customer

The customer now benefits from:

  • Increased comfort in summer and winter , with a stable temperature in all seasons.

  • Reduced energy bills , thanks to better efficiency compared to its old system.

  • With a successful aesthetic integration , the wall unit blends perfectly into the decor.

  • Peace of mind , with the AirGreen guarantee and Sharp reliability.

Why choose AirGreen in Montreal, Laval, Longueuil, North Shore and South Shore?

Our expertise in wall-mounted heat pump installation allows us to handle the most complex projects, even in confined urban environments. Whether for a duplex in Rosemont, a house in Laval, or a condo in Brossard, we always adapt our solutions to our clients' specific needs.

By choosing AirGreen, you benefit from:

  • From an RBQ certified and experienced team .

  • Comprehensive support in grant applications.

  • Optimized installations to maximize sustainability and energy efficiency .

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment