Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie

AirGreen installs a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie: positioning under cornice, white capping, gravity drainage and complete commissioning for quiet and energy-efficient HVAC comfort.

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie
Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie
–chapters in this story
6 minreading time
–type of installation
2025year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

Four-season comfort carefully integrated into an interior with Montreal character

At AirGreen , we work in many older plexes and condos in Greater Montreal where moldings, decorative lighting, and load-bearing walls require precise execution. This installation in Rosemont–La Petite-Patrie illustrates our approach: a Sharp wall-mounted heat pump installed under a textured cornice, near a wall-mounted light fixture, with a discreet appearance and measurable performance from the moment it is commissioned.


Housing context and client objectives

The owner wanted:

  • Stabilize the temperature of a southwest-facing living room, which is prone to overheating in summer and nighttime heat loss in winter.

  • Reduce energy bills without increasing ambient noise.

  • Preserve the aesthetics of a room dressed with original frames and moldings.

We recommended a Sharp wall-mounted heat pump (typical capacity of 9,000 to 12,000 BTUs for this volume), a versatile solution for mid-season supplemental heating and summer cooling, while remaining energy-efficient and quiet.


Choosing a location: airflow and aesthetics

The indoor unit is placed high on the wall , away from the cornice to avoid any recirculation of hot air to the ceiling. Our placement criteria:

  • Upper and lateral clearance respected for free suction and even diffusion towards the center of the room.

  • Move away from sources of interference (curtains, bulky frames, hot lamps which distort the temperature reading).

  • Height optimized for gravity drainage of condensates, avoiding the addition of a pump and limiting maintenance.

  • Blowing axis oriented so as to sweep the living area, without directing the flow directly onto the sofa.

The adjacent wall light required precise centering : we validated the opening of the shutters, access to the casing and the freedom of the thermistor sensor to guarantee faithful regulation.


Routing connections: treating the invisible

The installation is carried out in a back-to-back manner towards an exterior facade. We group together:

  • Insulated refrigeration tubes in HVAC class,

  • Certified communication/power cable ,

  • Continuously sloping condensate pipe .

Inside, a minimalist white capping accompanies the outlet towards the wall, then extends outside to protect the connections from UV rays , shocks and frost. Outside (not visible here), the condensing unit is mounted on wall brackets clear of the ground to promote water flow and limit snow accumulation, a crucial point in Montreal winters .


Technical particularities and precautions on this site

  • Moldings and textured ceiling : laser tracing to maintain lines perfectly parallel to the cornices; dowels adapted to the material; clean sealing of the drilling.

  • Decorative frames : air shedding control to avoid dead zones behind the paintings; low-speed vibration check to avoid transmitting hums to the wall.

  • Noise pollution : setting nighttime silent mode; checking desuperheating in air conditioning mode to prevent expansion whistling.

  • Condensates : slope > 1% guaranteed, service siphon and outlet outside the passage area to avoid any splashing on the masonry.


Why the Sharp wall-mounted heat pump is suitable for Rosemont

The Sharp wall series are distinguished by:

  • High efficiencies (SEER/HSPF) and precise compressor speed control for stable comfort.

  • Quiet operation , ideal for living rooms and bedrooms.

  • Efficient heating at low temperatures (down to approx. -20 to -25°C depending on the range), relevant for the North Shore , Laval and the heart of Montreal .

  • Advanced filtration and evaporator surface treatment limiting dust and humidity.

  • Compatibility with grant programs when the configuration meets Energy Star criteria and minimum heating performance.


Installation steps followed by AirGreen

  1. Load calculation and validation of BTU capacity for the main room.

  2. Identification/prototyping : position, drilling template, routing of connections and condensate discharge point.

  3. Fixing the wall plate with suitable anchors; checking the flatness to avoid flow noises.

  4. Through drilling at a downward angle; deburring the sheath; application of a vapor barrier .

  5. Installation of the Sharp indoor unit , testing of the shutters and the oscillation.

  6. Brazing/Torque-controlled flare fittings ; nitrogen priming , deep vacuum and leak testing .

  7. Electrical connection on dedicated circuit breaker in accordance with the Code ; circuit labeling.

  8. Commissioning : supply/return temperature measurements, superheat/subcooling, compressor intensity, vibration control.

  9. Delivery to the customer : operating instructions, seasonal adjustments, HVAC maintenance schedule.


Result: performance, silence and integration

The room quickly reaches the setpoint, without unpleasant drafts. The noise level remains low, even under load, and the visual integration respects the alignment of the moldings and frames. The uniform diffusion limits temperature strata, a point often criticized in apartments with high ceilings.


Advice on use and maintenance from our technicians

  • Filters : clean every 4 to 8 weeks during periods of intensive use.

  • Fins : Gentle dusting; do not obstruct the front face with oversized drapes or frames.

  • Heating mode : in very cold weather, leave the appliance running continuously to maintain compressor stability.

  • Remote control/thermostat : avoid direct sunlight which distorts the reading; activate eco programs at night.

  • Annual HVAC maintenance visit: check pressures, residual vacuum, drain, and clean the evaporator/condenser.


What AirGreen brings more

  • Certified team accustomed to the constraints of Montreal plexes (load-bearing walls, brick joints, cornices).

  • Clean finishes (adjusted capping, watertight seals, perfect level).

  • Support for subsidies for Montreal, Laval , Longueuil , North Shore and South Shore when the device and configuration are eligible.

  • Responsive after-sales service , with fast parts and diagnostics on the brands we install.


Need a careful HVAC installation in Greater Montreal?

We install wall-mounted heat pumps , wall-mounted air conditioners , and multi-zone systems, with an approach focused on customer service, technical precision, and sustainability. For projects in Montreal, Laval, Longueuil, the North Shore , or the South Shore , AirGreen guides you from sizing to grants, then ensures clear and predictable maintenance.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).