Job sheet · Project

Installation of a Sharp ZU1 wall-mounted heat pump in Griffintown (Le Sud-Ouest, Montreal)

AirGreen installs a Sharp ZU1 wall-mounted heat pump in Griffintown: short lines, gravity drainage, consistent comfort, and quiet condos. HVAC installation services in Montreal, Laval, Longueuil, North Shore, and South Shore.

By AirGreen Climatisation & Chauffage Admin6 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
6 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Sharp ZU1 wall-mounted heat pump in Griffintown (Le Sud-Ouest, Montreal)
Installation of a Sharp ZU1 wall-mounted heat pump in Griffintown (Le Sud-Ouest, Montreal)
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

An exemplary integration into an urban condo, designed for four-season comfort

At AirGreen , we recently installed a Sharp ZU1 wall-mounted heat pump in a bright condo in Griffintown (Le Sud-Ouest, Montréal) . The space features a textured concrete ceiling, a large bay window with a sliding door to the balcony, and a shallow lintel above the window—a typical feature of the city's recent towers. Our mandate: to provide efficient, quiet, and visually understated heating/cooling without compromising glazing or circulation.


Choice of location: uniform diffusion and careful aesthetics

We position the indoor unit at the top of the wall, centered on the bay window , in order to sweep the open area (living room + dining area) without blowing directly on the occupants. This installation:

  • maximizes controlled stratification of warm air in winter and destratification in summer;

  • avoids recirculation created by vertical curtains thanks to the fine adjustment of the motorized vanes ;

  • protects the unit from direct solar gain from the window for more stable temperature readings.

The routing of the connections is carried out in a discreet vertical capping placed on the left bank of the unit, with constant clearance. The wall passage towards the outside is done in the axis, as short as possible towards the balcony, which limits the length of lines (approximately 1.5 to 2.0 m visible inside/outside) and reduces pressure losses .


Technical details of the installation (AirGreen method)

Our teams apply a rigorous procedure, compliant with RBQ and manufacturer recommendations:

  1. Support and clearances

    • Level metal anchor plate, anchored into the concrete/masonry of the lintel;

    • Respect the upper and side clearances to ensure air intake and facilitate maintenance.

  2. Drilling and sealing

    • Hole saw with guide, drilling at a slight outward slope for gravity drainage ;

    • Vapor barrier and elastomeric sealant at interfaces to block moisture and stray air;

    • Clean finish of the wall pass-through, without chips on the interior facing.

  3. Refrigerant connections and power supply

    • Flared copper tubes with calibrated rings;

    • High density continuous insulation, butyl tape at joints;

    • 14/4 communication cable between condenser and head, routed in the same cover;

    • Power supply from the outdoor unit with dedicated circuit breaker according to the prescribed rating.

  4. Condensates

    • Gravity drainage through the wall pass-through (no pump), slope checked at level;

    • Protective sheath on the front for clean, drip-free drainage .

  5. Pressurization, vacuum and commissioning

    • Nitrogen test to detect the slightest micro-leak;

    • Deep vacuum (≤ 500 microns) and stabilization;

    • Superheat/subcooling checks, remote control settings (modes, dehumidification, programming).


Why the Sharp ZU1 in a downtown condo?

The Sharp ZU1 ( R-32 refrigerant) is distinguished by:

  • DC Inverter Technology : fine modulation of the compressor, stable comfort without temperature fluctuations;

  • Quiet on the inside, ideal for compact living spaces;

  • High yields and resistance to Quebec cold (effective heating in extreme cold);

  • Advanced filtration and intelligent defrosting , limiting cycles and extending lifespan;

  • Grant compatibility when combined with current efficiency criteria (provincial program, seasonal efficiency).

In a condo, reducing line length and gravity drainage help optimize the actual COP on a daily basis. The result: less consumption, more comfort, and very quiet operation.


Site constraints and AirGreen solutions

  • Low concrete ceiling + short lintel : we chose a millimeter installation height to maintain the upper suction clearance while freeing up access to the slats.

  • Full-height glazing and vertical blinds : shutters are set to sweep mode to prevent air from collapsing onto the curtain; blowing instructions are set to extend the reach to the back of the living room.

  • Balcony access in the middle of the day : planning of drilling and installation of the condenser to minimize the time the door is down and reduce dust (continuous suction during drilling, protective covers).


Measurable result: immediate comfort and lasting performance

Upon commissioning, the occupant notes:

  • a uniform temperature throughout the open area;

  • a significant reduction in ambient noise compared to the old portable device;

  • precise control thanks to programmable scenes (presence/absence, night);

  • the possibility of an effective dehumidification mode during mid-season humid episodes.

Over the year, the R-32 + Inverter combination and the short installation of the lines contribute to significant energy savings , especially in supplementary heating mode during peaks.


Best practices and operating advice (condo)

  • Keep the set temperature stable (rather than large deviations) to enhance the Inverter modulation.

  • Clean the pre-filter every 4 to 6 weeks during periods of heavy use.

  • Leave space in front of the unit (avoid tall furniture or large plants).

  • In winter, favor a moderate setting at night to limit defrosting cycles.

  • Schedule an annual AirGreen HVAC maintenance : exchanger check, pressures, connections, condensates, calibration.


Grants and Compliance

The installed configuration meets the efficiency requirements generally required for eligibility for current grant programs . We support our customers in:

  • validate the adequate power (BTU) per zone;

  • document invoices and serial numbers ;

  • transmit the necessary files to the relevant authorities.


Why entrust your HVAC installation to AirGreen in Montreal, Laval, Longueuil, North Shore and South Shore?

  • Wall and multi-zone specialists (Sharp, Fujitsu, Midea, Gree, Zephyr, Elios, etc.);

  • Proven methodology : nitrogen test, vacuum draw, performance measurements;

  • Careful finishing (aligned cappings, rainproof seals, clean drillings);

  • Responsive after-sales service , parts and local maintenance;

  • Impartial advice on model selection based on building envelope and actual use.


Conclusion

This Sharp ZU1 wall-mounted heat pump installation in Griffintown demonstrates how a well-designed project can transform the comfort of an urban condo: uniform diffusion , silence , energy savings and aesthetic integration . With AirGreen, every detail—from drilling to programming—is designed for lasting comfort, winter and summer, throughout Greater Montreal .

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment