Installation of a Sharp ZU1 wall-mounted heat pump in Rosemont–La Petite-Patrie
At AirGreen, we installed a Sharp ZU1 wall-mounted heat pump in Rosemont–La Petite-Patrie: rear drilling, gravity drain, discreet finishes, and rigorous commissioning for four-season comfort. We serve Greater Montreal.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Precise comfort for a Montreal ground floor, installed cleanly and designed to last
Project background
In a bright ground floor in Rosemont–La Petite-Patrie , the client was looking for efficient supplemental heating and discreet cooling for the living area (open kitchen and living room). We recommenda Sharp ZU1 series wall-mounted heat pump (R-32), ideal for Montreal homes looking for four-season performance with controlled consumption.
The installed equipment
-
Type : wall-mounted heat pump (mini-split)
-
Brand : Sharp
-
Range : ZU1 (new generation R-32)
-
Target capacity : 12,000 BTU for a main area of ~35–45 m²
-
Highlights : High seasonal efficiency, quiet operation, easy-access filters, wide-sweep motorized damper, lower GWP refrigerant ( R-32 ).
Objective: to ensure stable comfort while reducing energy bills in the face of Montreal 's typical weather peaks.
HVAC Installation Details
-
Indoor installation : head placed ~20 cm from the ceiling to promote the Coanda effect and minimal air stratification .
-
Connection route : careful rear drilling (Ø ≈ 65 mm) with gravity slope for condensate drainage to the outside, avoiding any unnecessary condensate pump .
-
Estimated length of refrigeration lines: ~3–4 m, ideal for limiting pressure losses and maintaining efficiency.
-
Finish : discreet interior capping , white tint, aligned with the moldings; stainless steel screws.
-
Vibration attenuation : calibrated pads and spacers; check of the tightening torque of the flared fittings; balance test of the flap to avoid whistling.
-
Testing and commissioning : deep vacuum (< 500 microns), nitrogen leak test , overheating/subcooling check, then calibration of the instructions.
Construction site challenges and solutions
-
Reduced ceiling height near a room corner: we positioned the head to optimize air intake and diffusion, without hindering circulation or wall furniture.
-
Short route but sensitive crossing : controlled drilling with clean coring, watertight sheath and vapor barrier to prevent the entry of parasitic air and condensation in cold weather.
-
Interior aesthetics : minimalist routing, low-projection trunking, clean cut at the baseboards for a harmonious finish.
Result for the occupant
-
Rapid cooling in summer, efficient heating in the off-season and as a supplement in winter.
-
Low noise level : the interior head remains very quiet during regulation.
-
Temperature uniformity : automatic scanning covers the entire living area; hot/cold spots are reduced.
-
Optimized consumption : the inverter finely adjusts the power, limiting on/off cycles.
What the Sharp ZU1 brings to a Montreal home
-
R-32 : better environmental profile than R-410A and very good thermodynamic performance.
-
Extreme cold : regulation designed for our winters, with maintenance of capacity at low temperatures* ( within the range; we calibrate the size and operating curve according to the part ).
-
Filtration : Front access to filters for simple and frequent HVAC maintenance , ensuring cleaner air and stable performance.
Eligibility and subsidies (depending on configuration)
Depending on the BTU capacity and seasonal efficiency of the selected configuration, the installation may be eligible for assistance programs in Quebec. We validate the criteria on a case-by-case basis with our clients in Montreal, Laval, Longueuil, the North Shore, and the South Shore and prepare the necessary files.
Usage tips to maximize comfort
-
Constant setpoint : avoid sudden variations; let the inverter work.
-
Automatic sweep : in summer, orient slightly upwards to diffuse without direct air current; in winter, horizontal sweep to mix the stratified air.
-
Open doors : To cool the hallway and adjoining rooms, leave the passageways open during heat waves.
-
Dehumidification mode : useful in spring and summer for hygroscopic comfort without overcooling.
Recommended HVAC maintenance
-
Filters : Rinse every 4–6 weeks during heavy use.
-
Exchanger & turbine : annual professional cleaning to maintain flow and prevent deposits.
-
Outdoor unit (courtyard/balcony side): 30–45 cm clearance, cleaning of fins, preventive de-icing in winter if accumulation.
-
Annual inspection : checking pressures , operating temperatures , condensate drainage and tightness of connections.
Common mistakes to avoid
-
Undersize capacity for an open living area.
-
Block the recovery (shelves, frames, beams).
-
Forget the gravity slope or the drain sleeve through the wall, sources of drips or unwanted cold air.
-
Neglecting the vacuum and the test : these steps determine the longevity of the compressor.
Why choose us?
At AirGreen , we manage everything: load calculation , head selection , aesthetic integration, standardized installation , commissioning checks and support for subsidies . Our team dedicated to Greater Montreal responds quickly in Montreal, Laval, Longueuil, North Shore and South Shore , with planned slots to limit housing immobilization.
Site sheet - in brief
-
Address : Rosemont–La Petite-Patrie sector (Montreal)
-
Appliance : Sharp ZU1 series wall-mounted heat pump (R-32), 12,000 BTUs calibrated for the living area
-
Installation : high head, rear drilling , gravity drain, connections ~3–4 m, discreet white capping
-
Commissioning : deep vacuum, nitrogen test, thermodynamic checks, fine adjustments of the shutter
-
Objective : four-season comfort and control of operating costs
Need a similar project?
We recommend, size, and install wall-mounted heat pumps tailored to your building: plex, condo, or house. Contact AirGreen for a quick study and an accurate quote.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).