Installation of a Sharp wall-mounted heat pump in Chomedey (Laval)
AirGreen installs a Sharp wall-mounted heat pump in Chomedey (Laval): raised support, short lines, gravity evacuation and careful commissioning. Your HVAC reference in Montreal, Laval, Longueuil, North Shore, South Shore .
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
A clean, fast, and sustainable construction site: how we optimize each residential HVAC installation for stable, four-season comfort, even along Laval's main boulevards.
Project context and comfort objectives
In Chomedey, a residential area with a mix of plexes and single-family homes, our client wanted to upgrade their air conditioning system and benefit from supplemental heating in the mid-seasons. We recommended a Sharp wall-mounted heat pump (compact Eco Inverter outdoor unit with Plasmacluster technology) to combine energy efficiency, air quality, and quiet sound.
Device and configuration selected
-
Machine type: single-zone wall-mounted heat pump .
-
Brand: Sharp (Eco Inverter range, Plasmacluster ionization technology for indoor air quality).
-
Capacity: sized according to the main air-conditioned surface area and the building envelope (thermal load calculations carried out by our teams).
-
Objectives: efficient summer air conditioning, additional heating down to low temperatures, filtration and odor reduction through ionization.
At AirGreen, we always size capacity based on actual thermal losses and gains (orientation, fenestration, insulation, infiltration), never "by eye." This approach avoids short cycles, additional electrical costs, and discomfort.
Outdoor installation: stability, clearances and maintenance
The outdoor unit sits on a raised galvanized aluminum stand , anchored to the ground and wall to resist freeze-thaw and maintain clear clearance in front of the propeller.
Key heights:
-
Raising the height by approximately 30–40 cm to maintain free suction, facilitate snow removal and prevent premature corrosion.
-
Side and rear clearances respected to optimize airflow and simplify maintenance.
The raised support also limits vibration transmission to the slab and keeps the unit away from water accumulations during heavy rain. Direct access from the terrace and the side door allows for quick service without crossing the living areas.
Refrigeration path and condensate management
The lineset route is short and direct: crossing the rear wall behind the unit to reach the interior head.
-
Estimated length: short (≈ 2–3 m), reducing pressure losses and improving seasonal efficiency.
-
Continuous insulation of refrigeration pipes to limit heat gain in summer and frost in winter.
-
Visible gravity evacuation of condensates (white pipe), preferred when the slope allows it in order to avoid the addition of a pump and its associated maintenance.
When the architecture requires it, we use finishing ducts (capping) arranged on the facade; here, the short path behind the unit makes the line discreet without any major visual addition.
Power supply and protections
The heat pump is connected to a dedicated circuit with a circuit breaker at the main panel, in accordance with Quebec standards. An external disconnect switch (or proximity circuit breaker, depending on the configuration) is provided to ensure safe work. We systematically check the grounding , the panel capacity and the quality of the connections to avoid voltage drops that could be harmful to inverter compressors.
Key steps of installation
-
Checking the structure and clearances, precise choice of location.
-
Controlled drilling of the wall with waterproof wall pass-through and vapor barrier.
-
Installation of the raised support , leveling and vibration damping.
-
Refrigeration connection (clean bending, torque tightening), vacuum and leak tests.
-
Electrical connection with compliant protections.
-
Commissioning : fan settings, shutters, target temperatures and explanation of best practices to the customer.
Result: targeted comfort and controlled consumption
-
Quiet air conditioning of living spaces, without aggressive drafts.
-
Efficient supplemental heating in spring and fall, limiting the demand on the main systems.
-
Air quality enhanced by Plasmacluster ionization, useful for reducing odors and particles.
Points of attention that we manage for you
-
Winter defrosting: keep the area under the unit clear for drainage; our elevation helps with this.
-
Snow and ice: provide a snow guard or screen if the roof projects accumulations above.
-
Noise and neighborhood: fine speed adjustments and compliance with clearances for discreet operation.
-
HVAC maintenance: cleaning filters, annual inspection of pressures and connections; regular maintenance preserves performance and longevity.
Grants and Eligibility
Several assistance programs in Quebec target high-efficiency heat pumps . Eligibility depends on the low-temperature performance of the chosen model and installation compliance. We will work with you to validate the technical data sheets and criteria in effect for Montreal, Laval, Longueuil, the North Shore, and the South Shore , and prepare the necessary filing documents.
Usage and optimization tips
-
Maintain a stable setpoint (rather than large deviations) to take advantage of the inverter compressor.
-
Clear the suction and discharge openings ; avoid storing objects in front of the unit.
-
Schedule an annual maintenance reminder with AirGreen: residual vacuum check, probes, fans, clamps and deep cleaning.
Why AirGreen for your project in Laval and Greater Montreal?
We combine thermal diagnostics , meticulous installation and responsive after-sales service . Our experience in the Chomedey, Vimont, Duvernay neighborhoods, as well as in Montreal intramural , the South Shore and the North Shore , allows us to anticipate local constraints (snow, frost, access, noise) and deliver lasting comfort, without compromising on aesthetics.
Need a wall-mounted heat pump installation in Laval or elsewhere in Greater Montreal? We'll schedule a technical visit, estimate the right capacity, review your grant options, and ensure a clean, safe, and optimized installation for your home.
Keywords: heat pump , wall-mounted heat pump , HVAC installation , HVAC maintenance , Sharp , Montreal , Laval , Longueuil , North Shore , South Shore .
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).