Installation of a Sharp ZU1 wall-mounted heat pump in Plateau-Mont-Royal
In Plateau-Mont-Royal, AirGreen installs a Sharp ZU1 (R-32) wall-mounted heat pump with a corridor head: balanced diffusion, gravity drain, careful finishing and HVAC maintenance. Turnkey service for Montreal, Laval, Longueuil, North Shore and South Shore.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
An interior head placed in the corridor to efficiently serve three rooms and gain comfort all year round
Project context and objectives
In Plateau-Mont-Royal, a condo owner wanted to modernize his four-season comfort without major renovations or wasting space. We proposed the installation ofa Sharp ZU1 series wall-mounted heat pump ( R-32 ), known for its heating efficiency in cold weather and its fine modulation. The choice of an interior head installed high up in the central hallway allows for air conditioning and heat to be supplied to the two side bedrooms as well as the central area, while freeing up the walls of the main rooms.
Equipment selected: Sharp ZU1 series (R-32)
The ZU1 series brings together:
-
inverter technology with wide modulation range to avoid short cycles;
-
solid performance in low temperature heating and optimized defrosting on the outdoor unit side;
-
R-32 refrigerant , more efficient than R-410A;
-
soft electronics ( Quiet/Night mode) and improved filtration for better air quality.
Typical sizing for an urban condo is between 12,000 and 15,000 BTUs for a central area. We perform a thermal assessment (envelope, orientation, infiltration) to precisely adjust the capacity—an essential condition for energy efficiency and acoustic comfort.
Interior head layout: corridor, height and blowing angles
The corridor has several advantages when you want to serve several rooms with a single head:
-
useful height : installation at ~2.2–2.3 m above the doors, ensuring unobstructed air intake;
-
longitudinal diffusion : the shutters oriented at 10–15° run along the corridor, the air being distributed naturally towards the adjacent rooms when the doors are half-open;
-
nighttime comfort : the central position and silent mode limit noise perception in the bedrooms.
We respect the manufacturer's recommended top and side clearances , avoid closed niches and ensure easy access to the hood for filter maintenance.
Fixing, crossings and interior finishes
To preserve the lightweight partitions of an urban building:
-
the fixing counterplate is anchored with metal dowels adapted to the structure (uprights identified by the detector, reinforcement if necessary);
-
laser leveling and vibration controls;
-
passage of the gravity drain with continuous slope towards the outside and integrated anti-siphon ;
-
refrigeration connections and communication cable covered in a discreet white molding, positioned to keep the corridor uncluttered.
Each opening (exterior wall/technical column) is treated with a vapor barrier and compatible mastic to prevent condensation and infiltration.
Refrigeration route and connections
The route of the connections connects the head of the corridor to the technical volume on the outside by the shortest route, limiting bends. We:
-
insulate the copper tubes with thick cellular nitrile ;
-
protect the exposed sections against UV rays ;
-
respect the maximum lengths and the level difference prescribed for the ZU1 series;
-
We supply the equipment via a dedicated circuit with compliant external disconnection ; the indoor head is only supplied by the low voltage communication from the condenser.
Condensate management: safety and cleanliness
In the corridor, any drop would be visible. We pay particular attention to the drain:
-
constant slope (>1%) to the exit point;
-
rigid or semi-rigid pipe with anchor collars;
-
leak test with clear water before closing the hoods;
-
If the configuration requires it, a compact condensate pump can be added; here, the layout allows for reliable, silent and maintenance-free gravity flow .
Acoustics, air quality and control
The Sharp ZU1 head combines a tangential fan and an internal shroud reducing turbulence:
-
low sound levels in Quiet mode , suitable for night hours;
-
internal sensors optimizing temperature and ventilation speed;
-
easily accessible filters for quick HVAC maintenance by the occupant.
The remote control (or Wi-Fi module when chosen) allows time slots , management of hydro peaks and fine control of the setpoint according to occupancy.
AirGreen commissioning: method and controls
To guarantee the advertised performance, our protocol includes:
-
Nitrogen test of the connections to validate the tightness;
-
Deep vacuum (< 500 microns) and stabilization;
-
Opening of valves and load adjustment according to the manufacturer's table;
-
Checking currents , overheating/subcooling ;
-
Condensate test (filling of tank, flow);
-
Setting of modes (heating, cooling, dehumidification) and seasonal settings;
-
Customer usage brief, including energy saving instructions.
Results: cross-functional comfort and sobriety
In a condo configuration in Plateau-Mont-Royal:
-
the air blown into the corridor evenly supplies the side rooms, reducing temperature gradients between rooms;
-
in summer, dehumidification stabilizes humidity and prevents the feeling of heavy air;
-
In winter, the heat pump takes over from the electric baseboards and reduces operating costs , particularly in mid-season when the COP is highest.
Grants and Eligibility
High-efficiency wall-mounted heat pumps (R-32, low-temperature operation) may be eligible for assistance programs. Our team manages administrative support for customers in Montreal, Laval, Longueuil, the North Shore, and the South Shore and provides the required technical documents (model numbers, performance sheets, proof of installation).
HVAC Maintenance: Keeping Performance at Its Best
-
FILTERS : monthly rinsing during periods of use;
-
EVAPORATOR : seasonal gentle cleaning to maintain heat exchange;
-
DRAIN : visual inspection of the corridor (no odor, no seepage), annual test;
-
OUTDOOR UNIT : cleaning the battery, clearing around the unit, checking the UV insulation ;
-
AirGreen ANNUAL VISIT : electrical measurements, inspection of connections, condition of the cover and update of parameters.
Regular maintenance ensures quietness , efficiency and extends the life of the ZU1 series.
Pitfalls to avoid and best practices (AirGreen feedback)
-
Avoid placing your head too close to the ceiling : respect the clearance for correct air intake;
-
Do not blow directly on an open door : orient the vanes for a flow along the corridor;
-
Take care of the drain (slope, anti-siphon): a corridor must remain impeccable;
-
Limit tight bends in connections to preserve load and performance;
-
Adjust the capacity to the actual load: an oversized machine is noisy and less comfortable.
Why AirGreen
At AirGreen, we combine precise sizing , impeccable HVAC installation and turnkey service (quotes, co-ownership coordination, technical documentation, subsidies, HVAC maintenance ). Our experience with urban buildings—narrow corridors, clean crossings, drain management—guarantees a durable, quiet and aesthetic result. This Sharp ZU1 installation in Plateau-Mont-Royal illustrates our approach: an ideally placed head, optimized connections and transversal comfort for the entire dwelling.
Do you have a central hallway and are unsure of the ideal location? We assess airflow and heat load, and recommend a Sharp or equivalent heat pump perfectly suited to your condo in Montreal and throughout the Greater Montreal area.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).