Job sheet · Project

Installation of a MIDEA EVOX G3 3-ton central heat pump in Sainte-Julie (South Shore)

HVAC Installation in Sainte-Julie: MIDEA EVOX G3 3-ton central heat pump. Optimal comfort, energy efficiency, and available grants on the South Shore and in Montreal.

By AirGreen Climatisation & Chauffage Admin4 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
4 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a MIDEA EVOX G3 3-ton central heat pump in Sainte-Julie (South Shore)
Installation of a MIDEA EVOX G3 3-ton central heat pump in Sainte-Julie (South Shore)
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea EVOX G3 · 1.5 tons14,70018,600−30 °C: 11,8002.1219.010.1$1,764
Midea EVOX G3 · 2 tons20,80020,600−30 °C: 12,1002.1418.610.0$2,496
Midea EVOX G3 · 2.5 tons24,00033,200−30 °C: 17,9001.9717.210.8$2,880
Midea EVOX G3 · 3 tons33,00037,400−30 °C: 27,6001.918.010.0$3,960
Midea EVOX G3 · 4 tons39,50048,000−30 °C: 27,2002.017.59.5$4,740
Midea EVOX G3 · 5 tons45,00054,000−30 °C: 37,3001.917.59.5$5,400

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

A Complete Transformation of Thermal Comfort in a Sainte-Julie Residence

At AirGreen, we recently completed a major HVAC installation in Sainte-Julie, on the South Shore of Montreal, involving a MIDEA EVOX G3 3-ton central heat pump. This project perfectly illustrates our approach: rigorous analysis, impeccable technical execution, and a constant focus on optimizing comfort and energy performance.

The client, owner of a single-family home built in the 2000s, wanted to replace an old, inefficient, and noisy central system. The objective was clear: to achieve stable heat in winter, uniform air conditioning in summer, and significantly reduce energy costs.


Why the MIDEA EVOX G3 was the ideal choice for this installation

Performance Adapted to Quebec Winters

The MIDEA EVOX G3 central heat pump stands out for its ability to maintain heating performance down to -30°C, which is essential in a region like Sainte-Julie, where winter temperatures can be extreme.

In this project, we particularly highlighted:

  • A cooling capacity of 36,000 BTU
  • A SEER2 of 17.7 for remarkable summer efficiency
  • An HSPF2 of 10.0, guaranteeing excellent heating performance
  • An ENERGY STAR® (Cold Climate) certification

These characteristics allow the system to operate efficiently all year round, without compromise.

An advantageous subsidy for the client

Thanks to the LogisVert program, our client was able to benefit from a subsidy of $3720, making this investment even more relevant. We provided full support for the administrative procedures, thus simplifying the process.


Technical Challenges Encountered on the Sainte-Julie Site

Space Constraints and Duct Optimization

One of the major challenges of this installation was the limited space in the mechanical room. The existing system occupied a poorly optimized configuration, with unbalanced ducts.

Our team had to:

  • Partially reconfigure the ductwork
  • Adapt the indoor unit for optimal maintenance access
  • Ensure homogeneous air circulation throughout the house

Thanks to the compact design of the MIDEA EVOX G3, we were able to integrate the system without compromising performance.

Outdoor Unit Installation: Stability and Durability

As seen in the installation, the outdoor unit was mounted on robust wall brackets, which allows for:

  • Better protection against snow accumulation
  • Reduced vibrations transmitted to the building
  • Increased system durability

We also made sure to:

  • Install a secure electrical supply
  • Optimize tubing passage (3/8 – 3/4)
  • Perform a complete vacuum pull with micron test

AirGreen Installation Process: Precision and Rigor

Every central heat pump installation carried out by our team follows a strict protocol:

Key project steps

  1. Free on-site evaluation
    • Complete thermal analysis
    • Verification of existing ductwork
    • Precise load calculation
  2. Technical preparation
    • Choice of optimal location
    • Planning of electrical and refrigeration connections
  3. Installation
    • Installation of indoor and outdoor units
    • Connection of refrigeration lines
    • Leak test and vacuum pull
  4. Commissioning
    • System calibration
    • Performance verification
    • Full explanation to the client

Results Achieved: Comfort, Silence, and Savings

Immediate Improvement in Comfort

From the first days following installation, the client noticed:

  • A uniform temperature in all rooms
  • A significant reduction in noise
  • Better humidity management

Reduced Energy Costs

Thanks to Inverter technology and the more ecological R-454B refrigerant, the system continuously adjusts its power, which leads to:

  • Fewer on/off cycles
  • Optimized energy consumption
  • A reduced monthly bill

Real Customer Testimonial (Summary)

The owner particularly appreciated:

  • The stability of heating even in very cold weather
  • The quiet operation of the outdoor unit
  • Intelligent control via WiFi

This type of feedback is consistent in our central heat pump installations in Laval, Longueuil, and Montreal, confirming the reliability of the model.


Practical Advice for Homeowners in Sainte-Julie and on the South Shore

What to Avoid

  • Choosing an undersized heat pump
  • Neglecting the condition of existing ducts
  • Ignoring the importance of professional installation

What We Recommend

  • Opt for an ENERGY STAR® certified system
  • Check eligibility for subsidies
  • Call on a specialized HVAC installation contractor

A Sustainable Solution for Homes in Greater Montreal

The MIDEA EVOX G3 central heat pump represents an excellent choice for residences in:

  • Montreal
  • Laval
  • Longueuil
  • North Shore
  • South Shore

It combines:

  • Cold weather performance
  • Energy efficiency
  • Consistent comfort

Conclusion: A Mastered HVAC Installation from A to Z

This installation in Sainte-Julie clearly demonstrates the importance of a well-executed job. At AirGreen, we don't just install a machine — we deliver a complete, tailored, durable, and high-performance solution.

Every project is unique, and our expertise allows us to anticipate challenges, optimize every detail, and guarantee a result that meets expectations.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

    1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
    2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
    3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
    4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
    5. The outdoor unitOn a level base, raised above the snow, with free space all around.
    6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
    7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
    8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
    9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: central heat pump, indoor module and ducts

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

    2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

    3. A shut-off switch near the outdoor unit isolates it safely for service.

    4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

    5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

    6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

    7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

    8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment