Installation of a MIDEA EVOX G3 central heat pump in Saint-Stanislas-de-Kostka
In Saint-Stanislas-de-Kostka, AirGreen installs a MIDEA EVOX G3 central heat pump on wall brackets, with a protected refrigerant line set and a finish matching the brick for a clean HVAC installation suited to Quebec’s climate.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.
The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.
A shut-off switch near the outdoor unit isolates it safely for service.
Sitting on the indoor module, it moves heat between the house air and the refrigerant.
Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.
Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.
It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.
It runs the heat pump and the backup heat. It must be compatible with the installed system.
In Saint-Stanislas-de-Kostka, a central installation where exterior finishing matters just as much as winter performance
This installation of a MIDEA EVOX G3 central heat pump in Saint-Stanislas-de-Kostka illustrates an aspect of HVAC work that is immediately noticeable on a home: how the equipment, refrigerant lines, and electrical connections are integrated into the building envelope.
In the photo taken after our work, the MIDEA heat pump is installed on metal wall brackets, in front of the home's foundation and beneath a large red brick wall. On the left, a mature hedge limits the available space. Higher up, a window must remain fully functional. To the right of the unit are the technical connections and the electrical disconnect. Finally, the refrigerant lines run vertically up the building inside a finished line set cover, whose main section was selected in a brown tone that blends much better with the brick and the existing exterior elements than a highly visible long white line set cover.
This last detail is particularly interesting. In a central heat pump installation, the lines between the outdoor unit and the indoor unit can cover a considerable distance. When they must run up along a brick facade, their routing becomes an architectural element that remains permanently visible. We therefore have to solve two problems at once: properly protect the lines and prevent the mechanical equipment from visually dominating the facade.
Here, the vertical route is clean, straight, and organized. The technical installation becomes much less intrusive.
What we see in the photo and why these details matter
The EVOX G3 condenser is installed high enough that it does not rest directly on the ground. The metal brackets transfer the load to the foundation and provide clearance beneath the unit.
This choice is important in Saint-Stanislas-de-Kostka, where the equipment must withstand several seasons of snow, freezing temperatures, rain, and thawing.
A heat pump used for heating periodically produces water during its defrost cycles. If the unit is placed too close to the ground, ice can accumulate beneath the cabinet and eventually reduce the available clearance. The installation height is therefore a real part of preparing the system for Quebec winters.
We also note in the photo:
- the fully unobstructed large front fan;
- the unit positioned away from the window;
- the triangulated brackets attached to the foundation;
- the condenser feet and mounting points;
- the insulated refrigerant line on the right side;
- the outdoor electrical disconnect switch in the immediate vicinity;
- the protected vertical path of the lines into the building;
- the hedge retained to the left of the installation;
- the absence of piping left exposed along the entire height of the wall.
These are small details when examined separately. Together, however, they determine the final quality of a residential HVAC installation.
Why install the EVOX G3 above ground level
The MIDEA EVOX G3 is part of a family of Inverter central heat pumps designed for low-temperature heating.
According to the Midea documentation provided for this installation, the Extreme Heat range can continue operating down to -30 °C. The manufacturer also indicates a heating capacity of up to 100% at approximately -25 °C, with a COP of approximately 1.9 under the specified test conditions.
A machine intended to continue operating at these temperatures must be installed accordingly.
It would be inconsistent to select a heat pump capable of operating at -25 °C or -30 °C and then position it somewhere where the first significant snow accumulation blocks the heat exchanger or reduces its defrosting clearance.
That is why we consider the following from the outset:
height, airflow, defrost water, accessibility, and the likely accumulation of snow around the house.
A front discharge that changes how the outdoor unit is positioned
The EVOX G3 uses a different format from many conventional central condensers with vertical fans.
Here, the fan discharges air horizontally toward the front.
Midea pairs this horizontal discharge with a vertical heat exchanger and indicates that this architecture is intended to promote more uniform airflow through the heat exchanger. The manufacturer also specifies that this design improves heat-exchange performance as the temperature drops.
In the context of this home in Saint-Stanislas-de-Kostka, this allows us to position the unit against the foundation while directing its discharge toward the open space in front of it.
The front area must nevertheless remain clear. A hedge, fence, bench, snow accumulation, or any other obstacle placed too close to the fan can interfere with operation.
The hedge next to the heat pump: a detail to monitor over time
The photo shows dense vegetation to the left of the unit.
During installation, the clearances required by the manufacturer must obviously be respected. But responsibility does not end once the work is completed.
A shrub grows.
A hedge that perfectly respects the clearances at the time of installation may eventually grow closer to the coil, reduce airflow, or make servicing more difficult.
Our practical advice for this type of setup is therefore simple: periodically trim the vegetation around the condenser and maintain the required clearances.
You should not wait for the branches to touch the heat pump.
A well-protected vertical refrigerant line route
One of the most distinctive elements of this installation is the outdoor path of the lines.
The connection leaves the heat pump on its right side, then runs up the wall before joining the rest of the system. Instead of leaving a long section of insulated copper, wires, and drain exposed, the main route is placed inside a vertical protective line set cover.
The dark color of the upper section integrates much better with the brick wall than a contrasting white cover running the entire height.
On a residential project, this finish serves several purposes:
- protect the refrigerant lines from impacts and the elements;
- stabilize the path of the lines;
- reduce the insulation's exposure to the sun;
- visually group the different elements;
- make integration with the façade easier;
- avoid an installation that looks like it was improvised afterward.
For us, this kind of detail is part of HVAC work, just like evacuation and pressure checks.
Why we never choose an EVOX G3 solely according to the BTU rating listed on a quote
The name MIDEA EVOX G3 refers to a product line, not a single capacity.
Midea documentation lists several capacities ranging from approximately 18,000 to 54,000 BTU/h, with performance ratings reaching up to 19 SEER2, 12.5 EER2, and 10.8 HSPF2, depending on the selected combination.
The specifications table includes, among others, the following combinations:
- 18,000 BTU: MAUSE-H18B-2A + MO1HE-H18B-2A;
- 24,000 BTU: MAUSE-H24B-2A + MO1HE-H24B-2A;
- 30,000 BTU: MAUSE-H30B-2A + MO1HE-H30B-2A;
- 36,000 BTU: MAUSE-H36B-2A + MO1HE-H36B-2A;
- 48,000 BTU: MAUSE-H48B-2A + MO1HE-H48B-2A;
- 54,000 BTU: MAUSE-H60B-2A + MO1HE-H60B-2A.
The rating plate visible on the side of the condenser in the photo is not legible enough for us to state with certainty the exact capacity of this particular unit. We prefer to preserve this distinction rather than attribute an unconfirmed tonnage to the project.
SEER2 and HSPF2: efficiency varies by model
Not all EVOX G3 units have exactly the same efficiency.
In the documentation provided, the Extreme Heat configurations are listed as follows:
18,000 BTU: 19 SEER2, 12.5 EER2, 10.1 HSPF2
24,000 BTU: 18.6 SEER2, 12 EER2, 10 HSPF2
30,000 BTU: 17.2 SEER2, 12 EER2, 10.8 HSPF2
36,000 BTU: 17.7 SEER2, 12 EER2, 10.0 HSPF2
48,000 BTU: 17.5 SEER2, 12 EER2, 9.5 HSPF2
54,000 BTU: 17.5 SEER2, 12 EER2, 9.5 HSPF2.
These figures illustrate an important reality: the best choice for a home is not necessarily the machine with the greatest capacity.
Proper sizing begins with the building.
What we analyze before choosing the tonnage of a central heat pump
To size a central heat pump in Saint-Stanislas-de-Kostka, we must notably assess:
- the home's heat loss;
- the heated area and volume;
- the insulation level;
- the windows;
- air infiltration;
- the duct system configuration;
- the available airflow;
- the auxiliary heating capacity;
- the electrical supply;
- the behavior of the existing system.
The duct system deserves particular attention.
A heat pump can provide a great deal of heat, but that heat must then be transported efficiently to the rooms.
Computational Constant Airflow 2.0: useful in existing duct systems
The EVOX G3 uses Computational Constant Airflow 2.0 technology.
Midea indicates that the indoor fan can adjust its speed and output to better maintain the requested airflow when system pressure changes. The documentation illustrates conditions of up to 1.2 in. of water column static pressure and mentions up to 60 airflow customization levels.
This function can be particularly relevant when replacing equipment in an existing home.
The resistance of the ductwork can change depending on:
- the duct dimensions;
- the length of the ductwork;
- the elbows;
- the condition of the filters;
- the type of filtration;
- the grilles;
- the return air openings;
- the damper configuration.
The goal, however, is not to use a more sophisticated fan to hide a poor ductwork system.
If the ductwork has a major restriction, we prefer to identify the problem and correct it whenever possible.
From the outdoor unit to the air handler: why the EVOX G3 works as a complete system
An indoor unit designed for renovation projects
The EVOX G3 is not limited to the gray condenser visible in the photo.
Inside, the system uses an air handler that must be integrated into the home's ductwork.
Midea developed a modular cabinet that can be installed in six orientations, including vertically, horizontally or in certain “low-boy” configurations for spaces with limited height.
This flexibility can make a big difference in a basement.
We frequently work in homes where the old unit has been surrounded over the years by finished walls, plumbing, a water heater or other equipment.
Being able to adapt the position of the indoor unit makes certain conversions easier without completely rebuilding the mechanical room.
A format designed to fit in the space occupied by many older furnaces
Midea specifies cabinet widths of approximately 14.5 to 21.5 inches, depending on capacity. The documentation also mentions a multivoltage indoor power supply of 115 V or 208/230 V.
This can facilitate the replacement of certain older central furnaces.
But “ease of replacement” never means “automatic installation.”
We always check the sheet metal transitions, return air, supply plenum, clearances, wiring and available capacity.
Up to 25 kW of auxiliary heating, but only when properly sized
Midea documentation provides for 10 kW, 15 kW and up to 25 kW auxiliary electric heater kits, with operation in multiple stages.
This function is important in Quebec.
Even with a high-performance heat pump in very cold weather, auxiliary heating may be used:
- under extreme conditions;
- during certain defrost cycles;
- to accelerate a significant temperature rise;
- as backup when demand exceeds the available capacity.
However, an electric element is not free from an energy standpoint.
We therefore avoid simply selecting « the biggest possible ».
The capacity must match the home and the electrical capacity actually available.
The choice between 485 communication and a 24 V thermostat
The EVOX G3 also offers some flexibility in terms of controls.
The documentation mentions compatibility with 485 communication as well as 24 V controls, with the possibility of integrating certain third-party thermostats in the specified configurations.
In a renovation project, this flexibility is valuable.
We can choose the appropriate strategy based on the existing wiring, the desired functions, and the equipment combination used.
With the Midea communicating system and the SmartHome app, the documentation also indicates programming, self-diagnostic, consumption monitoring, and remote update functions.
Filtration up to MERV 13, depending on the selected module
A central system can filter the air circulating throughout the home.
Midea provides a module compatible with 1-, 2-, or 4-inch filters, including MERV 13 in the configurations described.
MERV 13 can capture more fine particles than a very basic filter.
However, we must confirm that the ductwork can handle the additional resistance.
The right approach is not « more filtration at all costs », but the best balance between filtration and airflow.
R-454B: what the new generation changes for installation
Midea uses R-454B in the range described.
The brochure identifies it as a refrigerant A2L with a global warming potential, or GWP, of 466.
For the homeowner, the refrigerant remains essentially invisible.
For our team, however, it requires an adapted work method: compatible tools, handling procedures, circuit preparation, and commissioning in accordance with the requirements for this type of equipment.
Replacing an old R-410A heat pump with a modern unit must therefore never be treated as a simple box swap.
Eligibility for financial incentives: the exact combination number remains essential
Midea documentation indicates that the featured range exceeds the ENERGY STAR Most Efficient specifications mentioned by the manufacturer.
For a homeowner who wants to benefit from financial assistance such as LogisVert, this efficiency is appealing, but it is not enough to determine a precise amount.
At AirGreen, we always verify:
- the exact outdoor model;
- the exact indoor model;
- the certified combination;
- the applicable AHRI number;
- the installation date;
- the program criteria at the time of the work.
The name « MIDEA EVOX G3 » does not replace this verification.
The mistakes this installation helps avoid
Leaving the lines exposed across an entire façade
When the refrigerant line run is long and vertical, proper protection improves both durability and the final appearance.
Placing the heat pump directly against vegetation
The hedge visible on the left must remain trimmed to preserve airflow and service access.
Installing the unit too low
A heat pump designed to continue heating when it snows must maintain sufficient clearance from the ground and winter snow accumulation.
Neglecting access to the electrical disconnect
The disconnect device visible to the right of the unit must remain accessible for servicing.
Choosing the tonnage before checking the ductwork
A central system must be able to move the volume of air required by the selected capacity.
An installation that integrates into the home rather than simply being added to it
This Saint-Stanislas-de-Kostka project is particularly interesting because it shows how several relatively discreet decisions can completely change the result.
The heat pump is aligned with the foundation. It is elevated. The window remains unobstructed. The hedge is preserved. The connections are arranged on one side only. The disconnect switch is accessible. Above all, the long run to the upper part of the house is protected by a line set cover whose colour greatly limits the contrast with the brick wall.
These are the details we strive to master in every central heat pump installation.
The MIDEA EVOX G3 offers interesting technical features: Inverter technology, operation in very cold weather, R-454B, a modular indoor unit, advanced airflow management and various control options.
At AirGreen, our role is to turn these characteristics into a system that is truly suited to the building.
This is the same method we apply in our HVAC projects in Montreal, Laval, Longueuil, on the South Shore, on the North Shore and in municipalities such as Saint-Stanislas-de-Kostka: first understand the home, then install the equipment so that it is efficient, accessible, neat and durable.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Midea EVOX G3 · 1.5 tons | 14,700 | 18,600 | −30 °C: 11,800 | 2.12 | 19.0 | 10.1 | $1,764 |
| Midea EVOX G3 · 2 tons | 20,800 | 20,600 | −30 °C: 12,100 | 2.14 | 18.6 | 10.0 | $2,496 |
| Midea EVOX G3 · 2.5 tons | 24,000 | 33,200 | −30 °C: 17,900 | 1.97 | 17.2 | 10.8 | $2,880 |
| Midea EVOX G3 · 3 tons | 33,000 | 37,400 | −30 °C: 27,600 | 1.9 | 18.0 | 10.0 | $3,960 |
| Midea EVOX G3 · 4 tons | 39,500 | 48,000 | −30 °C: 27,200 | 2.0 | 17.5 | 9.5 | $4,740 |
| Midea EVOX G3 · 5 tons | 45,000 | 54,000 | −30 °C: 37,300 | 1.9 | 17.5 | 9.5 | $5,400 |
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
The equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
Access protected, old unit disconnected and removed when it is being replaced.
Electric furnace or air handler, with its coil, connected to the supply and return ducts.
On a level base, raised above the snow, with free space all around.
Insulated, they enter through a sealed opening and run to the indoor coil.
Dedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
Leak test, vacuum, start-up, airflow check and a test of both modes.
Filter, thermostat, backup heat in extreme cold: what to know before winter.
- The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
- The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
- Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
- The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
- The outdoor unitOn a level base, raised above the snow, with free space all around.
- The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
- Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
- Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
- The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Check the indoor module's filter.
- Clear winter debris from the outdoor unit.
- Test cooling before the heat arrives.
- Check the filter more often in peak season.
- Keep registers and returns clear.
- Watch condensate drainage near the coil.
- Change or clean the filter.
- Test heating and backup heat before the cold.
- Book periodic maintenance.
- Clear snow around the outdoor unit.
- Store nothing in front of the indoor module.
- Note any unusual noise or smell and call us.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. A central heat pump uses the house's ducts.
It connects to the existing ducts to heat and cool everywhere.
2. In extreme cold, electric backup heat can take over.
The indoor module (furnace or air handler) works with the heat pump and takes over in extreme cold.
3. The filter only gets changed when the unit breaks down.
A dirty filter cuts airflow. It gets checked regularly.
4. You can reuse the old unit's size without checking.
The house may have changed: insulation, windows, added rooms. Capacity is confirmed on site.
0 / 4 right answers
What people ask us about this kind of work
Can I keep my current ducts?
What happens in extreme cold?
Furnace, air handler, ducted: what is the difference?
Are there grants?
Do I need a permit?
How much can I save?
How is the LogisVert assistance calculated?
Will my current thermostat work?
Central or wall units: which one?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).