Installation d’une thermopompe double zone FUJITSU Aquila XLTH R32 24 000 BTU à l’Île-Bizard–Sainte-Geneviève
Reading time: 5'

Installation of a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève

Precise HVAC Installation in a Confined Space in the Heart of Île-Bizard–Sainte-Geneviève

At AirGreen, every HVAC installation presents a unique challenge, and this project completed in Île-Bizard–Sainte-Geneviève is an excellent example. In this residence, our team installed a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump, perfectly suited to the demands of Quebec's climate and the building's physical constraints.

From our first visit, it was clear that the positioning of the indoor units would require strategic thinking. As the installation shows, one of the wall-mounted units was positioned above a cabinet, close to the ceiling, with minimal clearance. This type of installation requires advanced expertise to ensure optimal airflow without compromising performance or comfort.


A FUJITSU Aquila XLTH Heat Pump Designed for the Greater Montreal Climate

Exceptional Performance Down to -26 °C

The FUJITSU Aquila XLTH R32 heat pump is specifically designed for the harsh winters of regions like Montreal, Laval, Longueuil, the North Shore, and the South Shore. Thanks to its heating capacity down to -26 °C, it guarantees constant comfort even during periods of intense cold.

Key Technical Specifications

  • Cooling Capacity: 24,000 BTU
  • Dual-Zone Configuration: independent control of two spaces
  • Refrigerant: R-32 (more ecological and efficient)
  • SEER2: 23.5
  • HSPF2: 11.5
  • Indoor Sound Level: as low as 19 dB (ultra-quiet)
  • ENERGY STAR® Certified (Cold Climate)
  • AHRI: 215447693

This combination of performance and energy efficiency allows homeowners to benefit from a reliable system while reducing their energy consumption.


Technical Challenges Encountered During Installation

Positioning Above Furniture: A Major Constraint

In this Île-Bizard–Sainte-Geneviève home, one of the main challenges was installing the wall-mounted unit in a confined space, directly above a built-in cabinet. This type of configuration carries several risks if poorly executed:

  • Poor air circulation
  • Heat accumulation near the ceiling
  • Limited access for future maintenance
  • Risk of amplified noise from surrounding surfaces

Our Professional Approach

At AirGreen, we applied a precise methodology to guarantee an optimal result:

  1. Airflow analysis: we adjusted the vane angle to direct air towards the living area, preventing it from getting trapped near the ceiling.
  2. Minimum clearance respected: despite the confined space, we maintained the necessary distances recommended by the FUJITSU manufacturer.
  3. Reinforced mounting: solid installation to prevent any vibration, particularly important in this type of enclosed environment.
  4. Anticipated maintenance access: we left a strategic space to allow for future cleaning without complex disassembly.

Dual-Zone Configuration: Personalized Comfort

Intelligent Zone Distribution

In this project, the dual-zone heat pump was configured to serve two distinct areas:

  • Zone 1: main living area (living room / open concept)
  • Zone 2: bedroom or secondary space

This configuration allows for independent temperature control, offering several advantages:

  • Significant energy savings
  • Personalized comfort based on room occupancy
  • Reduced system wear and tear

Concrete Example of Use

In this residence, occupants primarily use air conditioning in the living area during the day and in the bedroom in the evening. Thanks to dual-zone technology, they avoid unnecessarily cooling the entire house.


Fast and Clean Installation: AirGreen's Signature

One Day is Enough to Transform Comfort

Despite the technical constraints, our team completed this HVAC installation in Île-Bizard–Sainte-Geneviève in a single day. This included:

  • Installation of indoor units
  • Placement of the outdoor unit
  • Running of refrigerant lines
  • Electrical connections
  • Vacuuming and full testing

Impeccable Aesthetic Finish

An important point for our clients is always the final appearance. In this project:

  • Ductwork was neatly concealed
  • The wall-mounted unit blends discreetly into the decor
  • No visible damage to walls or structures

LogisVert Subsidy: Significant Savings

The FUJITSU Aquila XLTH 24,000 BTU heat pump installed in this project is eligible for the LogisVert subsidy from Hydro-Québec, which can amount to $1,944.

What This Means for Homeowners

  • Significant reduction in initial cost
  • Faster return on investment
  • Access to high-end technology at a lower cost

At AirGreen, we systematically assist our clients with the application process for this subsidy.


The Choice of R-32: A Strategic Advantage

The R-32 refrigerant used in this system offers several advantages over older gases like R-410A:

  • Better energy efficiency
  • Reduced environmental impact
  • Improved thermal performance
  • Reduced gas quantity

This choice is part of a sustainable approach, particularly important for residents of Greater Montreal.


Common Mistakes to Avoid in This Type of Installation

Improper Wall Unit Placement

Installing a unit too close to the ceiling or furniture without adjustment can drastically reduce efficiency.

Incorrect Sizing

An incorrectly sized heat pump leads to:

  • Excessive energy consumption
  • Uneven comfort
  • Premature wear

Uncertified Installation

Hiring an unqualified installer can lead to:

  • Warranty issues
  • Refrigerant leaks
  • Poor overall performance

Why Choose AirGreen in Montreal, Laval, Longueuil, North Shore, and South Shore

Real Field Expertise

We have carried out hundreds of similar installations in complex configurations. This project in Île-Bizard–Sainte-Geneviève demonstrates our ability to adapt to all situations.

Transparency and Professionalism

  • Clear pricing before work begins
  • No deposit required
  • Payment upon satisfaction

Local After-Sales Service

Our teams are readily available throughout Greater Montreal, ensuring efficient follow-up.


Conclusion: An Optimized HVAC Installation for Lasting Comfort

This installation of a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève perfectly illustrates the importance of precise and thoughtful work. Despite a restrictive space, our team delivered a powerful, aesthetic, and durable solution.

At AirGreen, we don't just install systems — we design solutions adapted to every residential reality.

Leave a comment