Job sheet · Project

Installation of a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève

Installation of a FUJITSU Aquila XLTH 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève. A high-performance HVAC solution, adapted to confined spaces and the climate of Montreal and its surroundings.

By AirGreen Climatisation & Chauffage Admin5 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
5 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève
Installation of a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève
The full story

The article, chapter by chapter

Precise HVAC Installation in a Confined Space in the Heart of Île-Bizard–Sainte-Geneviève

At AirGreen, every HVAC installation presents a unique challenge, and this project completed in Île-Bizard–Sainte-Geneviève is an excellent example. In this residence, our team installed a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump, perfectly suited to the demands of Quebec's climate and the building's physical constraints.

From our first visit, it was clear that the positioning of the indoor units would require strategic thinking. As the installation shows, one of the wall-mounted units was positioned above a cabinet, close to the ceiling, with minimal clearance. This type of installation requires advanced expertise to ensure optimal airflow without compromising performance or comfort.


A FUJITSU Aquila XLTH Heat Pump Designed for the Greater Montreal Climate

Exceptional Performance Down to -26 °C

The FUJITSU Aquila XLTH R32 heat pump is specifically designed for the harsh winters of regions like Montreal, Laval, Longueuil, the North Shore, and the South Shore. Thanks to its heating capacity down to -26 °C, it guarantees constant comfort even during periods of intense cold.

Key Technical Specifications

  • Cooling Capacity: 24,000 BTU
  • Dual-Zone Configuration: independent control of two spaces
  • Refrigerant: R-32 (more ecological and efficient)
  • SEER2: 23.5
  • HSPF2: 11.5
  • Indoor Sound Level: as low as 19 dB (ultra-quiet)
  • ENERGY STAR® Certified (Cold Climate)
  • AHRI: 215447693

This combination of performance and energy efficiency allows homeowners to benefit from a reliable system while reducing their energy consumption.


Technical Challenges Encountered During Installation

Positioning Above Furniture: A Major Constraint

In this Île-Bizard–Sainte-Geneviève home, one of the main challenges was installing the wall-mounted unit in a confined space, directly above a built-in cabinet. This type of configuration carries several risks if poorly executed:

  • Poor air circulation
  • Heat accumulation near the ceiling
  • Limited access for future maintenance
  • Risk of amplified noise from surrounding surfaces

Our Professional Approach

At AirGreen, we applied a precise methodology to guarantee an optimal result:

  1. Airflow analysis: we adjusted the vane angle to direct air towards the living area, preventing it from getting trapped near the ceiling.
  2. Minimum clearance respected: despite the confined space, we maintained the necessary distances recommended by the FUJITSU manufacturer.
  3. Reinforced mounting: solid installation to prevent any vibration, particularly important in this type of enclosed environment.
  4. Anticipated maintenance access: we left a strategic space to allow for future cleaning without complex disassembly.

Dual-Zone Configuration: Personalized Comfort

Intelligent Zone Distribution

In this project, the dual-zone heat pump was configured to serve two distinct areas:

  • Zone 1: main living area (living room / open concept)
  • Zone 2: bedroom or secondary space

This configuration allows for independent temperature control, offering several advantages:

  • Significant energy savings
  • Personalized comfort based on room occupancy
  • Reduced system wear and tear

Concrete Example of Use

In this residence, occupants primarily use air conditioning in the living area during the day and in the bedroom in the evening. Thanks to dual-zone technology, they avoid unnecessarily cooling the entire house.


Fast and Clean Installation: AirGreen's Signature

One Day is Enough to Transform Comfort

Despite the technical constraints, our team completed this HVAC installation in Île-Bizard–Sainte-Geneviève in a single day. This included:

  • Installation of indoor units
  • Placement of the outdoor unit
  • Running of refrigerant lines
  • Electrical connections
  • Vacuuming and full testing

Impeccable Aesthetic Finish

An important point for our clients is always the final appearance. In this project:

  • Ductwork was neatly concealed
  • The wall-mounted unit blends discreetly into the decor
  • No visible damage to walls or structures

LogisVert Subsidy: Significant Savings

The FUJITSU Aquila XLTH 24,000 BTU heat pump installed in this project is eligible for the LogisVert subsidy from Hydro-Québec, which can amount to $1,944.

What This Means for Homeowners

  • Significant reduction in initial cost
  • Faster return on investment
  • Access to high-end technology at a lower cost

At AirGreen, we systematically assist our clients with the application process for this subsidy.


The Choice of R-32: A Strategic Advantage

The R-32 refrigerant used in this system offers several advantages over older gases like R-410A:

  • Better energy efficiency
  • Reduced environmental impact
  • Improved thermal performance
  • Reduced gas quantity

This choice is part of a sustainable approach, particularly important for residents of Greater Montreal.


Common Mistakes to Avoid in This Type of Installation

Improper Wall Unit Placement

Installing a unit too close to the ceiling or furniture without adjustment can drastically reduce efficiency.

Incorrect Sizing

An incorrectly sized heat pump leads to:

  • Excessive energy consumption
  • Uneven comfort
  • Premature wear

Uncertified Installation

Hiring an unqualified installer can lead to:

  • Warranty issues
  • Refrigerant leaks
  • Poor overall performance

Why Choose AirGreen in Montreal, Laval, Longueuil, North Shore, and South Shore

Real Field Expertise

We have carried out hundreds of similar installations in complex configurations. This project in Île-Bizard–Sainte-Geneviève demonstrates our ability to adapt to all situations.

Transparency and Professionalism

  • Clear pricing before work begins
  • No deposit required
  • Payment upon satisfaction

Local After-Sales Service

Our teams are readily available throughout Greater Montreal, ensuring efficient follow-up.


Conclusion: An Optimized HVAC Installation for Lasting Comfort

This installation of a FUJITSU Aquila XLTH R32 24,000 BTU dual-zone heat pump in Île-Bizard–Sainte-Geneviève perfectly illustrates the importance of precise and thoughtful work. Despite a restrictive space, our team delivered a powerful, aesthetic, and durable solution.

At AirGreen, we don't just install systems — we design solutions adapted to every residential reality.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).