Installation of a SHARP ZU1 24,000 BTU Mini Split Heat Pump in Montreal
Experience efficient comfort with AirGreen’s SHARP ZU1 24,000 BTU heat pump in Montreal. With superior heating, cooling, and air purification, it’s perfect for Canadian winters and summers alike.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Efficient Comfort Year-Round: SHARP ZU1 Installation for Extreme Climates
When it comes to choosing an HVAC system that provides comfort even in the harshest conditions, the SHARP ZU1 24,000 BTU Mini Split Heat Pump is the epitome of efficiency, resilience, and technological innovation. At AirGreen, our commitment to bringing only the best solutions to our customers led us to install this exceptional system in Montreal, a city known for its intense winters and sweltering summers.
Why the SHARP ZU1 is Perfect for Montreal’s Climate
The SHARP ZU1 is engineered to thrive in the extreme temperature variations found in Montreal and surrounding areas, including Laval, Longueuil, North Shore, and South Shore. This system stands out for its remarkable heating capacity even at temperatures as low as -27°C. With the ZU1, you can enjoy reliable warmth during the coldest days, ensuring your home remains a haven of comfort regardless of the outdoor climate.
Key Features of the SHARP ZU1 24,000 BTU Mini Split Heat Pump
- Cooling Capacity: 24,000 BTU, providing effective cooling during hot summers
- Heating Capability: Operational down to -27°C, perfect for Canadian winters
- Efficiency: 22.0 SEER for energy savings
- Technology: Equipped with SHARP’s Plasmacluster Ion Technology for cleaner indoor air
- Warranty: 10 years on compressor, parts, and labor – guaranteeing peace of mind
Installation Details and Process
This installation in Montreal was meticulously executed by our team, ensuring optimal placement and secure mounting to maximize both efficiency and longevity. The outdoor unit, measuring 33.47 x 13 x 27.94 inches, is designed for durability in various weather conditions, while the indoor unit provides unobtrusive comfort with dimensions of 41.42 x 9.80 x 12.44 inches.
The installation process included:
- Site Assessment – Evaluating the ideal location for both interior and exterior units to ensure efficient air distribution and ease of access for maintenance.
- Mounting and Positioning – Secure mounting for the outdoor unit to withstand Montreal’s weather variations.
- Piping and Wiring – Using high-quality pipes (1/4 - 3/8) and ensuring proper insulation and secure connections.
- Testing and Calibration – Fine-tuning the settings for maximum efficiency and minimal noise, with sound pressure levels kept at 53 dB(A) outdoors and 25-49 dB(A) indoors.
Plasmacluster Technology: Clean Air, Pure Comfort
SHARP’s Plasmacluster Technology is more than just an air filter. It actively purifies the air by releasing ions that neutralize airborne bacteria, viruses, and odors, ensuring that the indoor environment is as fresh as it is comfortable. This feature is particularly beneficial for urban environments like Montreal, where indoor air quality can often be compromised.
Benefits of Plasmacluster Technology
- Eliminates airborne bacteria and viruses: Promoting a healthier home environment
- Removes odors: Ideal for eliminating persistent smells from cooking, pets, or tobacco
- Reduces mold growth: Helps maintain cleaner indoor air quality
Energy Efficiency and Environmental Responsibility
The SHARP ZU1 Heat Pump uses the R-32 refrigerant, known for its low environmental impact compared to traditional refrigerants. This installation aligns with our commitment to sustainability, as R-32 reduces the greenhouse effect, helping homeowners lower their carbon footprint.
Additionally, with a 22.0 SEER rating, this mini split heat pump is designed to keep energy bills low. This efficiency makes it eligible for a substantial Hydro-Québec LogisVert Grant, offering up to $2,688 – the highest available in the 18,000 BTU category, helping to offset installation costs for our customers.
Why Choose AirGreen for Your SHARP Heat Pump Installation?
At AirGreen, we understand that each home has unique HVAC needs, especially in regions like Montreal with diverse seasonal demands. Our team of certified professionals brings experience and dedication to every installation, ensuring that systems like the SHARP ZU1 function at their best. From precise installation techniques to thorough testing, we prioritize quality, efficiency, and customer satisfaction in every project.
Our Promise to You
- Expert Installation: We ensure every unit is optimally placed and securely mounted.
- Ongoing Support: Our service doesn’t end with installation; we provide regular maintenance and support.
- Maximized Grants: We help you take full advantage of available grants, reducing your investment.
- Top-Notch Equipment: Partnering with leading brands like SHARP ensures you receive high-quality, durable products.
SHARP ZU1 Installation: Bringing Comfort and Efficiency to Montreal Homes
This recent installation demonstrates our commitment to combining innovation with expertise. The SHARP ZU1’s advanced technology, combined with our professional installation, ensures that our clients in Montreal enjoy consistent, efficient, and eco-friendly comfort all year round.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).