Sustainable comfort and modern energy efficiency for a Laval home
At AirGreen , we have just completed the installation of a GREE Clivia R32 wall-mounted heat pump in a residence in the Vimont sector of Laval . This high-performance model offers excellent energy efficiency , while ensuring optimal comfort in both summer and winter—an ideal combination for Laval homes keen to reduce their energy consumption.
An HVAC solution adapted to the configuration of the accommodation
The installation took place in a high-ceilinged interior room in the heart of a typical single-family home in Laval. We positioned the wall-mounted head in the center of the wall , at an ideal height to ensure uniform air circulation throughout the space. The indoor unit features a sleek, compact design, perfectly integrated into the room's understated aesthetic.
The outdoor unit, installed at the rear of the property, is connected to the indoor head by a short run of refrigerant lines, carefully hooded and insulated to ensure maximum performance and increased durability in the face of harsh Quebec winters.
Choosing the GREE Clivia R32: performance, reliability and respect for the environment
The GREE Clivia R32 model represents the new generation of wall-mounted heat pumps using R-32 refrigerant, which is much more environmentally friendly than R-410A.
The advantages for the owner are numerous:
-
Superior energy efficiency (up to 23 SEER)
-
Heating capacity down to -25°C , ideal for Laval winters
-
Quiet operation , perfect for bedrooms and offices
-
Minimalist and modern design
-
Eligibility for provincial grants through its Energy Star certification
Technical details of the AirGreen installation
Our certified technicians carried out a complete turnkey installation :
-
Wall drilling optimized to minimize conduit length.
-
Routing of refrigerant connections along a clean and discreet route, with white capping matching the walls.
-
Secure electrical connection tested to CSA standards.
-
Complete commissioning, including pressure and leak tests , as well as calibration of the integrated thermostat.
The system has been configured to maintain a stable indoor temperature of 19°C , as displayed on the unit's digital panel, ensuring immediate comfort after installation.
A fast, clean and professional intervention
Our teams completed this installation in a single day, without interrupting the occupants' comfort. Every step, from attaching the wall plate to final commissioning, was executed with the attention to detail that characterizes AirGreen : cleanliness of the site, perfect alignment, and comprehensive performance testing before handover to the client.
Grants and potential savings
Thanks to the energy performance of the Clivia R32 , the owner will be able to benefit from assistance programs such as:
-
Rénoclimat and Chauffez vert , for the transition to high-efficiency systems;
-
Electricity savings of 30 to 40% on heating compared to a traditional electric furnace.
Why trust AirGreen in Laval?
By choosing AirGreen, customers in Laval and Greater Montreal benefit from:
-
RBQ and EPA certified technicians ;
-
Installations comply with the latest residential HVAC standards ;
-
Full warranty on parts and labor;
-
Local, fast and courteous service.
Our team supports each client from the choice of heat pump to the grant application , in order to maximize the return on investment while providing lasting comfort.
AirGreen – Experts in wall-mounted heat pumps in Laval, Montreal, Longueuil, North Shore and South Shore.
We transform each installation into a reliable, aesthetic and efficient project.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).