Installation of a Sharp wall-mounted heat pump in Rosemont–La Petite-Patrie
Discover how AirGreen installed a Sharp wall-mounted heat pump on a flat roof in Rosemont–La Petite-Patrie: raised support, Eco Inverter technology and four-season comfort perfectly adapted to the realities of Montreal housing.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
In Rosemont–La Petite-Patrie, many duplexes and triplexes are situated on flat roofs and narrow streets. It is precisely in this type of building that we installed thisSharp wall-mounted heat pump , a high-performance and discreet solution to ensure comfort in both summer and winter, without sacrificing aesthetics or space.
The customer's need: more comfort, less noise
Our client wanted:
-
Replacing a noisy and energy-inefficient portable air conditioner;
-
Enjoy a truly efficient heating system in winter, without being totally dependent on electric baseboard heaters;
-
Install the outdoor equipment discreetly and safely on a flat roof, without transmitting vibrations into the dwelling;
-
Opt for a recognized brand and a certified installation, eligible for various energy efficiency programs.
After analyzing the thermal load and constraints of the building, we recommended a Sharp ZU1 18,000 BTU wall-mounted heat pump , a modern Inverter model perfectly suited to the needs of a well-insulated 4 1/2–5 1/2 type home.
The installed system: a high-performance Sharp wall-mounted heat pump
The chosen solution is based on:
-
Brand: Sharp
-
System type: wall-mounted heat pump (single-zone mini-split)
-
Model: Sharp ZU1, Eco Inverter technology
-
Use: Four-season heating and cooling, with high energy efficiency
Inverter technology allows the compressor's power to be continuously adjusted according to actual demand. The result:
-
fewer temperature variations;
-
quieter operation;
-
reduced electricity consumption;
-
improved component durability.
Sharp's ZU1 series is designed to withstand Quebec winters , with stable heating capacity at low temperatures, while also providing efficient air conditioning during the humid heat waves of July and August.
Outdoor installation details: stability, durability and aesthetics
The photo shows the installed Sharp Eco Inverter outdoor unit:
-
On an elevated aluminum support , itself anchored on treated wooden blocks to distribute the load on the roof membrane;
-
With anti-vibration pads under the feet of the support to limit the transmission of vibrations to the structure;
-
Placed against a protected facade wall and directly sheltered from prevailing winds, this improves the device's performance in heating mode;
-
Positioned at a sufficient height to remain clear of water, accumulated snow and debris;
-
With a lateral clearance respected in relation to the fence and the wall, ensuring good air circulation around the condenser.
This configuration allows:
-
optimal flow of hot air in summer and cold air in winter;
-
a reduction in the risk of ice buildup on the unit;
-
simplified access for maintenance and seasonal checks.
We also paid particular attention to the routing of the refrigerant lines and electrical wiring, all protected in aesthetically pleasing and UV-resistant conduits. The result: a clean installation, well integrated into the building, and easy to inspect.
Interior installation details: comfort in living areas
Inside the dwelling, the Sharp wall-mounted head was installed:
-
In the main living area, at a height allowing for even air distribution ;
-
In order to avoid blowing directly on the occupants, for a gentle and constant comfort;
-
With an adequate slope for condensate drainage, reducing the risk of drips or bad odors.
The indoor unit is controlled via an easy-to-use wall-mounted remote control. The customer can:
-
precisely adjust the desired temperature;
-
choose the heating, air conditioning, dehumidification or ventilation modes;
-
schedule time slots according to one's lifestyle;
-
Adjust the fan speed and airflow direction.
Energy efficiency and savings in Rosemont–La Petite-Patrie
In an area like Rosemont–La Petite-Patrie , where more and more homeowners want to reduce their electricity bills without sacrificing comfort, a properly sized Sharp wall-mounted heat pump offers several advantages:
-
Reducing heating costs by shifting a large part of the load from electric baseboard heaters to a more efficient system;
-
High-efficiency air conditioning during the hot season;
-
Positive impact on the carbon footprint, thanks to better energy use;
-
Possibility of eligibility for certain financial assistance programs (when available and according to the criteria in force).
By choosing a Sharp Eco Inverter system, the customer is investing in a device known for its reliability, while benefiting from AirGreen's expertise in design, installation and after-sales service.
Why entrust your Sharp project to AirGreen?
At AirGreen, we:
-
Let's assess the actual needs of your accommodation (surface area, insulation, exposure, number of occupants);
-
We recommend the right BTU capacity , neither undersized nor oversized;
-
Let's plan with you the placement of the indoor unit and the outdoor unit to maximize performance and discretion;
-
We carry out installations that comply with the electrical and refrigeration standards in force in Quebec;
-
We provide maintenance and repair services to keep your investment in perfect condition.
This Sharp wall-mounted heat pump installation in Rosemont–La Petite-Patrie illustrates our approach well: meticulous work, designed for the realities of Montreal buildings, and entirely focused on the comfort of the occupants.
Conclusion: A Sharp heat pump designed for urban living
Thanks to this installation, our client now benefits from:
-
four-season comfort, suitable for harsh winters as well as summer heatwaves;
-
of a silent, discreet and efficient system;
-
of a safe and durable outdoor installation, perfectly integrated on the roof;
-
professional support from AirGreen, from the first visit to commissioning.
Do you live in Rosemont–La Petite-Patrie or another neighbourhood in Greater Montreal and are considering a Sharp wall-mounted heat pump ? We would be happy to analyze your project and offer you a customized solution.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).