Job sheet · Project

Installation of a SHARP ZU1 Wall-Mounted Heat Pump in Repentigny

Explore our latest installation in Repentigny! The SHARP ZU1 heat pump combines cutting-edge technology, eco-friendly refrigerant, and unbeatable comfort—ideal for Quebec winters.

By AirGreen Climatisation & Chauffage Admin5 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
5 minto read the whole story
–type of installation
2024year published
At a glance

The job on one screen

The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Bringing Superior Comfort and Innovation to Repentigny Homes

In Repentigny, we had the privilege of installing the SHARP ZU1 18,000 BTU Wall-Mounted Heat Pump, a state-of-the-art system designed for Quebec’s challenging climate. This project not only highlights the incredible capabilities of the SHARP ZU1 but also demonstrates our meticulous attention to detail and commitment to providing unparalleled customer satisfaction.


A Machine Built for Performance and Efficiency

The SHARP ZU1 is an industry-leading heat pump, celebrated for its superior efficiency and cutting-edge features. With a cooling capacity of 18,000 BTUs and a heating capacity capable of operating in temperatures as low as -27°C, this unit is perfectly tailored for Quebec’s extreme winters and sweltering summers.

Key Specifications:

  • Energy Efficiency: 24.0 SEER
  • Refrigerant: R-32 (eco-friendly and highly efficient)
  • Sound Pressure Levels: Quiet operation at 25-49 dB(A) indoors and 52 dB(A) outdoors
  • Warranty: 10-year coverage on parts, labor, and compressor
  • WiFi Connectivity: Advanced control via smartphone app

These features make the SHARP ZU1 a top choice for homeowners seeking efficiency, comfort, and advanced functionality.


Installation of a SHARP ZU1 Wall-Mounted Heat Pump in Repentigny

The Installation Process

Every installation is an opportunity to craft a seamless blend of performance and aesthetics. In this project, we faced the challenge of optimizing the placement of the outdoor unit while ensuring easy accessibility for maintenance. The exterior unit, measuring 33.47 x 13 x 27.94 inches, was mounted securely on a custom-built steel bracket under the client's deck. This positioning not only protects the unit from the elements but also minimizes its visual impact on the property.

To complement the high-tech functionality of the heat pump, we installed insulated piping and neatly concealed electrical wiring using durable, weather-resistant conduits. This ensures long-term reliability while maintaining a clean and professional appearance.


Harnessing the Power of Plasmacluster Technology

The SHARP ZU1 is equipped with Plasmacluster technology, a unique feature that purifies indoor air by neutralizing airborne bacteria, mold, and allergens. Here’s how it works:

  1. Ion Diffusion: Positively and negatively charged ions are released into the air.
  2. Neutralization of Contaminants: These ions attach to and destroy airborne pollutants.
  3. Transformation into Humidity: The ions return to the air as water molecules, enhancing indoor comfort.

For families in Repentigny, this means a healthier, fresher living environment—perfect for those with allergies or respiratory sensitivities.


Why Choose SHARP’s Coanda Airflow Control?

The Coanda airflow control system ensures that warm and cool air is distributed evenly throughout the home. Unlike traditional units that can create uncomfortable drafts, the SHARP ZU1 directs air along walls and ceilings, providing uniform comfort. With its 15-meter airflow reach, this unit guarantees balanced temperatures across all areas of the home.


Eco-Friendly Innovation with R-32 Refrigerant

One of the standout features of the SHARP ZU1 is its use of R-32 refrigerant, which reduces environmental impact by lowering greenhouse gas emissions and improving energy efficiency by up to 10%. This refrigerant aligns perfectly with Quebec’s push for sustainable, green energy solutions.


Admissible for the Highest LogisVert Grant

Homeowners in Quebec can rejoice as the SHARP ZU1 qualifies for the $2,640 LogisVert grant from Hydro-Québec—the highest subsidy available for an 18,000 BTU heat pump. This substantial rebate makes the SHARP ZU1 not only a performance powerhouse but also a cost-effective choice.


Designed for Quiet Comfort

For the installation in Repentigny, our client emphasized the need for a quiet operation to maintain a peaceful home environment. The SHARP ZU1 delivered flawlessly, with noise levels as low as 25 dB indoors—so quiet, you’ll hardly notice it’s running.


Cutting-Edge Connectivity

The SHARP ZU1’s WiFi-enabled control system allows homeowners to manage temperature, monitor energy consumption, and set schedules—all through a smartphone app. With real-time notifications, users can optimize their energy usage and reduce waste.


A Perfect Solution for Harsh Winters

In Quebec’s unpredictable climate, reliability is paramount. The SHARP ZU1’s Hot Gas Pipe System and defrosting technology ensure consistent performance, even in temperatures as low as -27°C. This installation is a testament to our dedication to providing solutions that withstand the test of time and weather.


Our Commitment to Excellence

At AirGreen, we take pride in delivering not just a product but a complete experience. From the initial consultation to the final installation, our team ensured that every detail was addressed with precision. The result? A flawless integration of advanced technology into a family’s home, improving their comfort and energy efficiency for years to come.


Why Choose AirGreen for Your HVAC Needs?

We are more than just HVAC experts—we are your partners in creating a comfortable and sustainable home. Our team combines technical expertise with unparalleled customer service to ensure every project exceeds expectations. When you choose AirGreen, you’re not just investing in a heat pump; you’re investing in peace of mind.


Contact Us Today!

If you’re considering upgrading your HVAC system, contact us for a personalized consultation. Let us show you why AirGreen is the trusted name in Repentigny and beyond.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).