BU · 24,000 BTU, three heads
Outdoor AE-X3M24BU · heads AY-XPC9BU ×3
AHRI 213927543 · NEEP 507394 · R-32
Three 9,000 BTU SHARP heads in Kirkland: the kitchen, the living room and the main bedroom, on a 24,000 BTU outdoor unit. The job, then the comparison with the MIDEA28, from seasonal cost to the base pan heater.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A Kirkland house with three 9,000 BTU wall heads: the kitchen, the living room and the main bedroom, on a single 24,000 BTU SHARP outdoor unit. Here is the job, then what SHARP and MIDEA publish for winter, certificate by certificate.

Outdoor AE-X3M24BU · heads AY-XPC9BU ×3
AHRI 213927543 · NEEP 507394 · R-32

Outdoor MO4HX-H27B-2A · wall heads of the series
AHRI 215471460 · NEEP 387279 · R-454B
AirGreen estimate for the same 24,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The MIDEA28 is certified at 27,000 BTU/h in cooling at 35 °C and the SHARP BU at 24,000; the comparison puts both in front of the same house, a 24,000 zone. Only each one’s certified efficiency changes the result. Electric baseboards serve as a reference point.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The owner wanted each room set its own way, because each family member has a preferred temperature. AirGreen mounted three 9,000 BTU SHARP wall heads, all connected to a 24,000 BTU SHARP AE-X3M24BU outdoor unit.
The open kitchen has its own head, high on the wall facing the counter. The living room and the main bedroom each have theirs, set separately.
The 9 + 9 + 9 combination is on the list SHARP publishes for the AE-X3M24BU (2025 brochure, p. 13).
In winter, a heat pump defrosts its outdoor coil; the water runs down into the pan under the unit. A base pan heater keeps that pan clear when it freezes. The MIDEA28’s NEEP listing describes its heater: 150 W and a precise cycle. The SHARP BU’s listing shows none.
Schematics. The cycle is the one NEEP listing 387279 describes for the MIDEA28: below 3 °C for 30 seconds, after 25 minutes of running, the base pan heater turns on for 5 minutes. The calculation assumes this cycle repeats for all the hours chosen, at the Rate D average price, taxes included. It is not added to the estimate in the Cost section.
The maximum heat each outdoor unit can still deliver once the thermometer drops below −15 °C. Common point: −15 °C, certified for both. Colder, SHARP certifies −27.2 °C and MIDEA −30 °C. Between two published values, the table shows the range, with no invented figure.
Only the features written in the SHARP 2025 brochure, the MIDEA28 multi-zone brochure or each system’s NEEP listing are listed. What a document does not mention is stated as such.
MIDEA NEEP listing: 150 W, 5 minutes after 25 minutes of running, below 3 °C.
SHARP No base pan heater on the NEEP listing; not found in the 2025 brochure.
SHARP List in the 2025 brochure, p. 13, including 9/9/9.
MIDEA Up to 4 zones; the brochure’s combination table is partly unreadable.
SHARP The brochure names the Plasmacluster technology. No effect is repeated here.
MIDEA Not found in the brochure.
MIDEA The brochure names SynchroConnect, which checks the wiring between the units.
SHARP Not found in the 2025 brochure.
SHARP Not found in the 2025 brochure.
MIDEA Not found in the multi-zone brochure.
SHARP −27 to 24 °C.
MIDEA Not printed in the brochure; NEEP certifies a point at −30 °C.
How to read these numbers. Neither SHARP nor MIDEA states the method or distance of measurement for these values, so they do not compare from one unit to the other. For the heads, SHARP publishes 23 to 43 dB(A) (9BU); the wall-head column of the MIDEA28 brochure is not readable enough to use.
Why this is not a ranking. A few decibels’ difference, measured two different ways, says nothing about what you hear from a neighbour’s yard.
Measurements taken by each manufacturer with its own method, not stated: different method — not comparable.
Front view, dimensions published by each manufacturer. The MIDEA28 is wider, taller and 53 lb heavier; the MIDEA28 brochure publishes no line lengths, ranges or electrical protection.
| Installation | SHARP BU | MIDEA28 |
|---|---|---|
| Maximum line length | 230 ft (70 m) totalSHARP 2025 brochure | Not published by the manufacturer in the multi-zone brochure |
| Maximum height difference | 33 ft (10 m)SHARP 2025 brochure | Not published by the manufacturer in the multi-zone brochure |
| Factory pre-charge | Not published by the manufacturer in the 2025 brochure | Not published by the manufacturer in the multi-zone brochure |
| Liquid – gas diameters | 1/4 – 3/8 inper head | Not published by the manufacturer in the multi-zone brochure |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 115 lb | 37 1/4 × 31 7/8 × 16 1/8 in, 168 lb |
| Indoor unit, weight | 34 39/64 × 11 3/8 × 9 1/64 in (9BU)weight not published | Not used: wall-head column unreadable in the brochure |
| Electrical protection | Max. fuse 25 A | Not published by the manufacturer208/230 V, single phase; MCA and MOP not printed |
| Advertised heating / cooling range | −27 to 24 °C / −10 to 46 °C | Not published by the manufacturer in the multi-zone brochure |
Outdoor unit dimensions follow each manufacturer’s printed order, brought back to width × height × depth. Electrical and refrigerant connections belong to contractors holding the required licences.
Every 24,000 BTU A2L multi-zone sold by AirGreen already has its page against the SHARP BU; the 27,000 MIDEA28 is among the closest that did not. Its certificate shows 27,000 BTU/h in cooling at 35 °C, against 24,000 for the SHARP. To stay on the same footing, the cost estimate puts both in front of the same 24,000 zone.
Yes. The SHARP 2025 brochure (p. 13) lists the 9/9/9 combination for the AE-X3M24BU, along with 9/9/12, 9/12/12 and 12/12/12.
It warms the pan under the outdoor unit, where defrost water runs, so the water drains instead of freezing. The MIDEA28’s NEEP listing describes a 150 W one; the SHARP BU’s lists none. Clearance under the unit (wall bracket or stand) still has to be planned in both cases.
The two numbers do not measure the same thing. Maximum capacity at −8.3 °C (30,000 versus 25,000 BTU/h) says how much heat the unit can deliver at that temperature. HSPF2 Region V (8.5 versus 9.0) sums up the electricity used over a whole season; that is what the calculation uses.
ASHRAE Standard 34 puts both refrigerants in the same class, A2L (mildly flammable). They differ in their 100-year global warming potential: 675 for R-32, 466 for R-454B (IPCC, Fourth Assessment Report).
NEEP lists both certificates (AHRI 213927543 and 215471460) as ENERGY STAR and cold climate. Each program’s official lists and amounts follow their own rules and change: check the list of the program concerned, for example Hydro-Québec’s LogisVert, before any purchase.
| Measure | SHARP BU 24,000 | MIDEA28 27,000 |
|---|---|---|
| Season | ||
| SEER2 | 24 | 23 |
| EER2 | 14 | 12.5 |
| HSPF2 Region IV | 11.5 | 10.5 |
| HSPF2 Region V | 9 | 8.5 |
| Rated capacity at 35 °C | 24,000 BTU/h | 27,000 BTU/h |
| Heating, min. / rated / max. | ||
| Capacity min. / rated / max. at 8.3 °C | 8,800 / 26,000 / 30,000 BTU/h | 8,400 / 27,000 / 36,000 BTU/h |
| COP min. / rated / max. at 8.3 °C | 4.69 / 4.35 / 4.19 | 4.92 / 3.8 / 3.1 |
| Capacity min. / rated / max. at −8.3 °C | 7,600 / 25,000 / 25,000 BTU/h | 6,000 / 30,000 / 30,000 BTU/h |
| COP min. / rated / max. at −8.3 °C | 2.93 / 2.53 / 2.53 | 2.93 / 2.36 / 2.36 |
| Capacity min. / rated / max. at −15 °C | 8,400 / 21,200 / 21,200 BTU/h | 5,400 / 27,000 / 27,000 BTU/h |
| COP min. / rated / max. at −15 °C | 2.46 / 2.3 / 2.3 | 2.43 / 2 / 2 |
| Coldest certified point | ||
| Test temperature | −27.2 °C (−17 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 5,100 / 14,600 BTU/h | 5,200 / 14,000 BTU/h |
| COP min. / max. | 1.74 / 1.84 | 2.18 / 1.26 |
| Listings | ||
| ENERGY STAR · cold climate | Yes, both | Yes, both |
| Refrigerant | R-32 · A2L · GWP 675 | R-454B · A2L · GWP 466 |
| AHRI certificate · NEEP listing | 213927543 · 507394non-ducted | 215471460 · 387279non-ducted |
higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities at different temperatures and the coldest point are not marked.
Three 9,000 heads or another combination: let’s talk about the rooms in your house.
Data verified November 17, 2026. Certified values: AHRI certificates, accessed in the NEEP database. Declared values: the manufacturers’ documents cited above.
SHARP, MIDEA and the other brands named belong to their owners. Logos and images are used only to identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a value look wrong? Write to us.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Three habits per season for this unit. They take a few minutes and prevent many calls.
Pick what looks like your need.
Flip each card to see what we do instead.
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).