Project

SHARP BU triple-zone heat pump installation in Kirkland, compared with the MIDEA28

Three 9,000 BTU SHARP heads in Kirkland: the kitchen, the living room and the main bedroom, on a 24,000 BTU outdoor unit. The job, then the comparison with the MIDEA28, from seasonal cost to the base pan heater.

By AirGreen Climatisation & Chauffage Admin12 min read
SHARP BU triple-zone heat pump installation in Kirkland, compared with the MIDEA28
SHARP BU triple-zone heat pump installation in Kirkland, compared with the MIDEA28
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Comparison · Multi-zone project · 3 heads

SHARP BU in Kirkland, compared with the MIDEA28

A Kirkland house with three 9,000 BTU wall heads: the kitchen, the living room and the main bedroom, on a single 24,000 BTU SHARP outdoor unit. Here is the job, then what SHARP and MIDEA publish for winter, certificate by certificate.

HSPF2 Region V
9.0·8.5
SHARP BU · MIDEA28, AHRI certificates
Max. heating at −8.3 °C
25,000·30,000
BTU/h, NEEP certified
Coldest certified point
−27.2 °C·−30 °C
14,600 · 14,000 BTU/h max.
Base pan heater listed at NEEP
no·150 W
below 3 °C, per the listing
SHARP
AirGreen product card for the SHARP BU triple-zone heat pump: three wall heads and the outdoor unit

BU · 24,000 BTU, three heads

Outdoor AE-X3M24BU · heads AY-XPC9BU ×3
AHRI 213927543 · NEEP 507394 · R-32

See the product page
MIDEA
AirGreen product card for the MIDEA28 multi-zone heat pump: three wall heads and the outdoor unit

MIDEA28 · 27,000 BTU, three zones

Outdoor MO4HX-H27B-2A · wall heads of the series
AHRI 215471460 · NEEP 387279 · R-454B

See the product page
Estimated running cost

A year of electricity in Kirkland, winter and summer

AirGreen estimate for the same 24,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The MIDEA28 is certified at 27,000 BTU/h in cooling at 35 °C and the SHARP BU at 24,000; the comparison puts both in front of the same house, a 24,000 zone. Only each one’s certified efficiency changes the result. Electric baseboards serve as a reference point.

How this amount is calculated
  1. The heat to supply. A zone whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature, with 4,167 degree-days below 18 °C (NRCan, HOT2000 climate map, Montréal Intl): about kWh of heat for a full winter, heating 24 hours a day. The heating slider reduces this total in proportion to the hours.
  2. Each heat pump’s electricity. Heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (NEEP). Electric baseboards use 1 kWh per kWh of heat.
  3. Cooling. 24,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000.
  4. The price. Hydro-Québec Rate D in force April 1, 2026: 7.065¢ per kWh up to 40 kWh per day, 11.142¢ above, 9.104¢ on average; × 1.14975 for GST and QST. The access charge, the same in every case, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The job · Kirkland

Kitchen, living room, bedroom: three 9,000 heads

White SHARP wall head mounted high on a green wall, above the kitchen and dining area
One of the three 9,000 BTU SHARP heads, above the open kitchen. Photo: AirGreen.

The owner wanted each room set its own way, because each family member has a preferred temperature. AirGreen mounted three 9,000 BTU SHARP wall heads, all connected to a 24,000 BTU SHARP AE-X3M24BU outdoor unit.

The open kitchen has its own head, high on the wall facing the counter. The living room and the main bedroom each have theirs, set separately.

The 9 + 9 + 9 combination is on the list SHARP publishes for the AE-X3M24BU (2025 brochure, p. 13).

9Kitchen9,000 BTU
9Living room9,000 BTU
9Main bedroom9,000 BTU
What stays from the original articleKirkland, the three rooms and their 9,000 BTU heads, the kitchen photo, the wish to set each room separately.
What was removedA rank taken from an older AirGreen guide, the grant amount, health effects attributed to ionization, environmental claims, the warranty and the “50.0 dB(A)” presented as quiet: none of it was backed by a verifiable document.
Below 3 °C

Defrost water and the outdoor unit’s base pan

In winter, a heat pump defrosts its outdoor coil; the water runs down into the pan under the unit. A base pan heater keeps that pan clear when it freezes. The MIDEA28’s NEEP listing describes its heater: 150 W and a precise cycle. The SHARP BU’s listing shows none.

SHARP BU AE-X3M24BU

MIDEA28 MO4HX-H27B-2A

Schematics. The cycle is the one NEEP listing 387279 describes for the MIDEA28: below 3 °C for 30 seconds, after 25 minutes of running, the base pan heater turns on for 5 minutes. The calculation assumes this cycle repeats for all the hours chosen, at the Rate D average price, taxes included. It is not added to the estimate in the Cost section.

Extreme cold

Kirkland in January: SHARP BU and MIDEA28 below −15 °C

The maximum heat each outdoor unit can still deliver once the thermometer drops below −15 °C. Common point: −15 °C, certified for both. Colder, SHARP certifies −27.2 °C and MIDEA −30 °C. Between two published values, the table shows the range, with no invented figure.

Features

Pan heater, wiring, Wi-Fi: what each document states

Only the features written in the SHARP 2025 brochure, the MIDEA28 multi-zone brochure or each system’s NEEP listing are listed. What a document does not mention is stated as such.

Outdoor unit base pan heater

MIDEA NEEP listing: 150 W, 5 minutes after 25 minutes of running, below 3 °C.

SHARP No base pan heater on the NEEP listing; not found in the 2025 brochure.

Published head combinations

SHARP List in the 2025 brochure, p. 13, including 9/9/9.

MIDEA Up to 4 zones; the brochure’s combination table is partly unreadable.

Plasmacluster ionization

SHARP The brochure names the Plasmacluster technology. No effect is repeated here.

MIDEA Not found in the brochure.

Wiring diagnostics

MIDEA The brochure names SynchroConnect, which checks the wiring between the units.

SHARP Not found in the 2025 brochure.

Wi-Fi control

SHARP Not found in the 2025 brochure.

MIDEA Not found in the multi-zone brochure.

Advertised heating range

SHARP −27 to 24 °C.

MIDEA Not printed in the brochure; NEEP certifies a point at −30 °C.

Sound

SHARP BU or MIDEA28 under the window: the printed decibels

dB

How to read these numbers. Neither SHARP nor MIDEA states the method or distance of measurement for these values, so they do not compare from one unit to the other. For the heads, SHARP publishes 23 to 43 dB(A) (9BU); the wall-head column of the MIDEA28 brochure is not readable enough to use.

Why this is not a ranking. A few decibels’ difference, measured two different ways, says nothing about what you hear from a neighbour’s yard.

Measurements taken by each manufacturer with its own method, not stated: different method — not comparable.

Installation

A MIDEA28 that weighs 53 lb more: both outdoor units at scale

Front view, dimensions published by each manufacturer. The MIDEA28 is wider, taller and 53 lb heavier; the MIDEA28 brochure publishes no line lengths, ranges or electrical protection.

InstallationSHARP BUMIDEA28
Maximum line length230 ft (70 m) totalSHARP 2025 brochureNot published by the manufacturer in the multi-zone brochure
Maximum height difference33 ft (10 m)SHARP 2025 brochureNot published by the manufacturer in the multi-zone brochure
Factory pre-chargeNot published by the manufacturer in the 2025 brochureNot published by the manufacturer in the multi-zone brochure
Liquid – gas diameters1/4 – 3/8 inper headNot published by the manufacturer in the multi-zone brochure
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 115 lb37 1/4 × 31 7/8 × 16 1/8 in, 168 lb
Indoor unit, weight34 39/64 × 11 3/8 × 9 1/64 in (9BU)weight not publishedNot used: wall-head column unreadable in the brochure
Electrical protectionMax. fuse 25 ANot published by the manufacturer208/230 V, single phase; MCA and MOP not printed
Advertised heating / cooling range−27 to 24 °C / −10 to 46 °CNot published by the manufacturer in the multi-zone brochure

Outdoor unit dimensions follow each manufacturer’s printed order, brought back to width × height × depth. Electrical and refrigerant connections belong to contractors holding the required licences.

Questions

Three 9,000 heads in Kirkland: questions about the job

The MIDEA28 carries 27,000: is the comparison still fair?

Every 24,000 BTU A2L multi-zone sold by AirGreen already has its page against the SHARP BU; the 27,000 MIDEA28 is among the closest that did not. Its certificate shows 27,000 BTU/h in cooling at 35 °C, against 24,000 for the SHARP. To stay on the same footing, the cost estimate puts both in front of the same 24,000 zone.

Three 9,000 heads on a 24,000 unit: is that listed?

Yes. The SHARP 2025 brochure (p. 13) lists the 9/9/9 combination for the AE-X3M24BU, along with 9/9/12, 9/12/12 and 12/12/12.

What does a base pan heater do?

It warms the pan under the outdoor unit, where defrost water runs, so the water drains instead of freezing. The MIDEA28’s NEEP listing describes a 150 W one; the SHARP BU’s lists none. Clearance under the unit (wall bracket or stand) still has to be planned in both cases.

The MIDEA28 heats more at −8.3 °C, so why does it cost more in the estimate?

The two numbers do not measure the same thing. Maximum capacity at −8.3 °C (30,000 versus 25,000 BTU/h) says how much heat the unit can deliver at that temperature. HSPF2 Region V (8.5 versus 9.0) sums up the electricity used over a whole season; that is what the calculation uses.

The SHARP uses R-32, the MIDEA28 R-454B: what does that change?

ASHRAE Standard 34 puts both refrigerants in the same class, A2L (mildly flammable). They differ in their 100-year global warming potential: 675 for R-32, 466 for R-454B (IPCC, Fourth Assessment Report).

Are the SHARP BU and the MIDEA28 on the assistance program lists?

NEEP lists both certificates (AHRI 213927543 and 215471460) as ENERGY STAR and cold climate. Each program’s official lists and amounts follow their own rules and change: check the list of the program concerned, for example Hydro-Québec’s LogisVert, before any purchase.

Certified data

SHARP BU 24,000 and MIDEA28 27,000, certificate against certificate

MeasureSHARP BU 24,000MIDEA28 27,000
Season
SEER22423
EER21412.5
HSPF2 Region IV11.510.5
HSPF2 Region V98.5
Rated capacity at 35 °C24,000 BTU/h27,000 BTU/h
Heating, min. / rated / max.
Capacity min. / rated / max. at 8.3 °C8,800 / 26,000 / 30,000 BTU/h8,400 / 27,000 / 36,000 BTU/h
COP min. / rated / max. at 8.3 °C4.69 / 4.35 / 4.194.92 / 3.8 / 3.1
Capacity min. / rated / max. at −8.3 °C7,600 / 25,000 / 25,000 BTU/h6,000 / 30,000 / 30,000 BTU/h
COP min. / rated / max. at −8.3 °C2.93 / 2.53 / 2.532.93 / 2.36 / 2.36
Capacity min. / rated / max. at −15 °C8,400 / 21,200 / 21,200 BTU/h5,400 / 27,000 / 27,000 BTU/h
COP min. / rated / max. at −15 °C2.46 / 2.3 / 2.32.43 / 2 / 2
Coldest certified point
Test temperature−27.2 °C (−17 °F)−30 °C (−22 °F)
Capacity min. / max.5,100 / 14,600 BTU/h5,200 / 14,000 BTU/h
COP min. / max.1.74 / 1.842.18 / 1.26
Listings
ENERGY STAR · cold climateYes, bothYes, both
RefrigerantR-32 · A2L · GWP 675R-454B · A2L · GWP 466
AHRI certificate · NEEP listing213927543 · 507394non-ducted215471460 · 387279non-ducted

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities at different temperatures and the coldest point are not marked.

The SHARP BU and the MIDEA28 are both available from AirGreen.

Three 9,000 heads or another combination: let’s talk about the rooms in your house.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP, listing 507394 (AHRI 213927543)SHARP AE-X3M24BU, non-ducted · accessed November 17, 2026
NEEP, listing 387279 (AHRI 215471460)MIDEA MO4HX-H27B-2A, non-ducted, base pan heater · accessed November 17, 2026
SHARP, 2025 brochure (French)BU series: combinations p. 13, heads, range, dimensions, sound · accessed November 17, 2026
MIDEA, MIDEA28 multi-zone brochure (EN)Undated; MO4HX-H27B-2A unit: dimensions, weight, sound, zones · accessed November 17, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · accessed November 17, 2026
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days, −23.1 °C · accessed November 17, 2026
IPCC Fourth Assessment Report · ASHRAE 34100-year GWP and refrigerant safety class
In figures
The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
The unit

What the unit delivers when it is cold

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp BU 24 0002 Zones (Dual Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Sharp BU 24 0003 Zones (Triple Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Most EfficientENERGY STAR

Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.

8,800BTU/h at low speed

Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.

−27 °CColdest certified point

NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.

675R-32 GWP

Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment