Job sheet · Project

SHARP BU triple-zone heat pump installation in the West Island, compared with the ELIOS e-Multi

A 24,000 BTU SHARP BU heat pump serves three heads in a West Island house: 12,000 in the living room, 9,000 in each bedroom. The job, then the comparison with the ELIOS e-Multi, certificate by certificate.

By AirGreen Climatisation & Chauffage Admin12 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
12 minto read the whole story
–type of installation
2024year published
At a glance

The job on one screen

SHARP BU triple-zone heat pump installation in the West Island, compared with the ELIOS e-Multi
SHARP BU triple-zone heat pump installation in the West Island, compared with the ELIOS e-Multi
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp BU 24 0002 Zones (Dual Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Sharp BU 24 0003 Zones (Triple Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Most EfficientENERGY STAR

Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.

8,800BTU/h at low speed

Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.

−27 °CColdest certified point

NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.

675R-32 GWP

Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Comparison · Multi-zone project · 3 heads

SHARP BU in the West Island, compared with the ELIOS e-Multi

A West Island house heated and cooled by three wall heads: 12,000 BTU in the living room and 9,000 in each of the two bedrooms. Here is the job, then what SHARP and ELIOS publish, certificate by certificate, for one outdoor unit that serves three rooms.

HSPF2 Region V
9.0·7.1
SHARP BU · ELIOS e-Multi, AHRI certificates
SEER2
24·23
seasonal cooling
Max. heating at −15 °C
21,200·19,000
BTU/h, NEEP certified
Outdoor unit liquid connections
3·4
SHARP combinations · ELIOS sheet
SHARP
AirGreen product card for the SHARP BU triple-zone heat pump: three wall heads and the outdoor unit

BU · 24,000 BTU, three heads

Outdoor AE-X3M24BU · heads AY-XPC9BU ×2 + AY-XPC12BU
AHRI 213927543 · NEEP 507394 · R-32

See the product page
ELIOS
AirGreen product card for the ELIOS e-Multi heat pump: three wall heads and the outdoor unit

e-Multi · 27,000 BTU, three heads

Outdoor EXHSA2742AV1 · heads EWHMA09C2AS1 / EWHMA12C2AS1
AHRI 216046639 · NEEP 383623 · R-454B

See the product page
Estimated running cost

One winter and one summer of electricity in the West Island

AirGreen estimate for the same 24,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. The ELIOS e-Multi carries the number 27,000 and the SHARP BU 24,000: the calculation keeps 24,000 for both, so the same house is the base. Only their certified efficiencies change. Electric baseboards serve as the reference.

How this amount is calculated
  1. The heat to supply. A zone whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature, with 4,167 degree-days below 18 °C (NRCan, HOT2000 climate map, Montréal Intl): about kWh of heat for a full winter, heating 24 hours a day. The heating slider reduces this total in proportion to the hours.
  2. Each heat pump’s electricity. Heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (NEEP). Electric baseboards use 1 kWh per kWh of heat.
  3. Cooling. 24,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000.
  4. The price. Hydro-Québec Rate D in force April 1, 2026: 7.065¢ per kWh up to 40 kWh per day, 11.142¢ above, 9.104¢ on average; × 1.14975 for GST and QST. The access charge, the same in every case, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The job · West Island

Three rooms, one unit outside

SHARP outdoor unit on a wall bracket against a brick wall, line cover painted the colour of the brick
The SHARP AE-X3M24BU outdoor unit on its wall bracket. Photo: AirGreen.

The owners wanted to heat and cool three rooms separately, without ducts. The living room got a 12,000 BTU head and each of the two bedrooms a 9,000 BTU head, all connected to a single 24,000 BTU SHARP outdoor unit.

The outdoor unit sits on a wall bracket, above the ground. The lines run up the brick inside a line cover painted the same colour as the wall.

The 9 + 9 + 12 combination is on the list SHARP publishes for the AE-X3M24BU (2025 brochure, p. 13). At start-up, the owners were shown how to control each head.

12Living room12,000 BTU
9Bedroom 19,000 BTU
9Bedroom 29,000 BTU
What stays from the original articleThe place, the three rooms, the head sizes, the photo of the outdoor unit and the wall-bracket choice.
What was removedA rank taken from an older AirGreen guide, grant amounts, health effects attributed to ionization, environmental claims and the warranty: none of it was backed by a verifiable document.
A fourth room later?

What an outdoor unit allows for later

Many West Island houses have a basement or an office that gets finished later. Add a room: each schematic shows the connections the manufacturer publishes for its outdoor unit, and the sum of the heads connected.

One more room
SHARP BU AE-X3M24BU · 24,000 BTU

Heads connected ÷ outdoor unit
ELIOS e-Multi EXHSA2742AV1 · 27,000 BTU

Heads connected ÷ outdoor unit

Schematics. The ratio is a simple division: the sum of the heads’ nominal capacities divided by the outdoor unit’s number. Each manufacturer sets its own limit on connected indoor capacity: SHARP turns it into a list of combinations; the September 2025 ELIOS e-Multi sheet does not publish it. Before adding a head, you need the manufacturer’s combination table.

Extreme cold

−20 °C nights: SHARP BU and ELIOS e-Multi below −15 °C

Maximum heating capacity of the outdoor unit, every point published below −15 °C. Both systems are certified at the same −15 °C point; lower down, SHARP certifies −27.2 °C and ELIOS −25 °C. Elsewhere, the table gives the range between two published values, never an invented number.

Features

What SHARP and ELIOS put in writing, feature by feature

Only the features written in the SHARP 2025 brochure and the ELIOS e-Multi sheet (September 2025) are listed. What a document does not mention is stated as such.

Refrigerant leak detection

ELIOS The sheet names R-454B leak detection, an automatic refrigerant shut-off valve, compressor shutdown and continuous indoor fan operation after a leak.

SHARP Not found in the 2025 brochure.

Head fan: published airflow

SHARP 9BU and 12BU heads: 145 to 438 CFM.

ELIOS 09 and 12 heads: 153 to 382.6 CFM (five speeds, the lowest not given).

Plasmacluster ionization

SHARP The brochure names the Plasmacluster technology. No effect is repeated here.

ELIOS Not found in the sheet.

Wi-Fi control

SHARP Not found in the 2025 brochure.

ELIOS Not found in the e-Multi sheet.

Advertised heating range

SHARP −27 to 24 °C.

ELIOS −25 to 24 °C.

Cooling in cold weather

SHARP Cooling range −10 to 46 °C.

ELIOS Cooling range −25 to 50 °C.

Sound

SHARP BU or ELIOS e-Multi in the yard: the printed decibels

dB

How to read these numbers. Neither SHARP nor ELIOS states the method or distance of measurement for these values, so they do not compare from one unit to the other. For the heads, SHARP publishes 23 to 43 dB(A) (9BU and 12BU); the ELIOS e-Multi sheet publishes no indoor sound level.

Why this is not a ranking. A gap of a few decibels measured two different ways says nothing about what you will hear in the yard.

Measurements taken by each manufacturer with its own method, not stated: different method — not comparable.

Installation

On a wall bracket: both outdoor units at the same scale

Front view, dimensions published by each manufacturer. The SHARP on this job is on a wall bracket; the same question applies to the ELIOS, which is wider, taller and 24 lb heavier.

InstallationSHARP BUELIOS e-Multi
Maximum line length230 ft (70 m) totalSHARP 2025 brochureNot published by the manufacturer in the 2025-09 e-Multi sheet
Maximum height difference33 ft (10 m)SHARP 2025 brochureNot published by the manufacturer in the 2025-09 e-Multi sheet
Factory pre-chargeNot published by the manufacturer in the 2025 brochure2.4 kg (84.66 oz)e-Multi sheet 2025-09
Liquid – gas diameters1/4 – 3/8 inper head1/4 – 3/8 in4 liquid connections 1/4 in; gas: 3 × 3/8 in + 1 × 1/2 in
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 115 lb37.24 × 31.89 × 16.14 in, 138.89 lb
Indoor unit, weight34 39/64 × 11 3/8 × 9 1/64 in (9BU and 12BU)weight not published31.57 × 11.61 × 7.87 in, 18.96 lb (09 and 12)
Electrical protectionMax. fuse 25 AMax. fuse or breaker 25 A208-230 V, single phase
Advertised heating / cooling range−27 to 24 °C / −10 to 46 °C−25 to 24 °C / −25 to 50 °C

Outdoor unit dimensions follow each manufacturer’s printed order, brought back to width × height × depth. Electrical and refrigerant connections belong to contractors holding the required licences.

Questions

This West Island job, in questions

Why compare a 24,000 with a 27,000?

Among the 24,000 BTU A2L multi-zones AirGreen offers, each already has its own comparison page with the SHARP BU. The 27,000 ELIOS e-Multi is one of the closest that did not. Its certificate gives 26,000 BTU/h cooling at 35 °C and 27,000 heating at 8.3 °C; the SHARP, 24,000 and 26,000. The cost calculation keeps 24,000 for both.

Does SHARP list the 9 + 9 + 12 combination?

Yes. The SHARP 2025 brochure (p. 13) lists for the AE-X3M24BU the three-head combinations 9/9/9, 9/9/12, 9/12/12 and 12/12/12, and the two-head combinations 9/9, 9/12, 9/18, 12/12, 12/18 and 18/18.

Can a fourth head be added later?

Not on the AE-X3M24BU: the combinations SHARP publishes stop at three heads. The ELIOS EXHSA2742AV1 has four liquid connections, but its sheet does not publish the allowed combinations; you need ELIOS’s table before choosing a fourth head.

Why does the ELIOS cost more to heat in the estimate?

The calculation divides the same heat by each certificate’s HSPF2 Region V: 9.0 for the SHARP BU, 7.1 for the non-ducted ELIOS e-Multi. For the same heat, the ELIOS therefore needs about 27% more electricity over the season.

R-32 and R-454B: what is the difference?

Both are classified A2L (mildly flammable) under ASHRAE Standard 34. Their 100-year global warming potential is 675 for R-32 and 466 for R-454B (IPCC Fourth Assessment Report).

Can the SHARP BU and the ELIOS e-Multi qualify for assistance?

At NEEP, both certificates (AHRI 213927543 and 216046639) carry the ENERGY STAR and cold-climate designations. Each program sets its own rules, amounts and lists, which change: check the eligible-equipment list of the program concerned, for example Hydro-Québec’s LogisVert, before buying.

Certified data

SHARP BU 24,000 and ELIOS e-Multi 27,000, certificate against certificate

MeasureSHARP BU 24,000ELIOS e-Multi 27,000
Season
SEER22423
EER21412.2
HSPF2 Region IV11.59.5
HSPF2 Region V97.1
Rated capacity at 35 °C24,000 BTU/h26,000 BTU/h
Heating, min. / rated / max.
Capacity min. / rated / max. at 8.3 °C8,800 / 26,000 / 30,000 BTU/h8,400 / 27,000 / 29,200 BTU/h
COP min. / rated / max. at 8.3 °C4.69 / 4.35 / 4.194.92 / 3.6 / 3.34
Capacity min. / rated / max. at −8.3 °C7,600 / 25,000 / 25,000 BTU/h6,000 / 23,600 / 23,600 BTU/h
COP min. / rated / max. at −8.3 °C2.93 / 2.53 / 2.532.93 / 2.14 / 2.14
Capacity min. / rated / max. at −15 °C8,400 / 21,200 / 21,200 BTU/h5,400 / 19,000 / 19,000 BTU/h
COP min. / rated / max. at −15 °C2.46 / 2.3 / 2.32.43 / 2 / 2
Coldest certified point
Test temperature−27.2 °C (−17 °F)−25 °C (−13 °F)
Capacity min. / max.5,100 / 14,600 BTU/h5,200 / 11,800 BTU/h
COP min. / max.1.74 / 1.842.18 / 1.5
Listings
ENERGY STAR · cold climateYes, bothYes, both
RefrigerantR-32 · A2L · GWP 675R-454B · A2L · GWP 466
AHRI certificate · NEEP listing213927543 · 507394non-ducted216046639 · 383623non-ducted

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities at different temperatures and the coldest point are not marked.

The SHARP BU and the ELIOS e-Multi are both available from AirGreen.

Three rooms or four, on a wall bracket or on the ground: let’s talk about your house.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP, listing 507394 (AHRI 213927543)SHARP AE-X3M24BU, non-ducted · accessed November 17, 2026
NEEP, listing 383623 (AHRI 216046639)ELIOS EXHSA2742AV1, non-ducted · accessed November 17, 2026
SHARP, 2025 brochure (French)BU series: combinations p. 13, heads, range, dimensions, sound · accessed November 17, 2026
ELIOS, “Multizone standard climate heat pumps e-Multi”Elios_e-Multi_202509_FR_V02 and EN_V02 · accessed November 17, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · accessed November 17, 2026
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days, −23.1 °C · accessed November 17, 2026
IPCC Fourth Assessment Report · ASHRAE 34100-year GWP and refrigerant safety class
Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment