Central heat pump or multi-zone: it all starts with your ducts

Home / Comparisons / Guides by type of system

Guide · House with or without ducts · 36,000 BTU examples

Central heat pump or multi-zone: it all starts with your ducts

A house heated by a forced-air furnace does not have the same options as a house heated by baseboards. A central system carries air to every room through the ducts, from a single indoor unit. A multi-zone system puts a unit in each room you choose, all connected to one outdoor unit. To make the comparison concrete, this guide takes two 36,000 BTU systems from the same family, each with its own AHRI certificate.

Indoor units: 1 and up to 4 HSPF2 V 8.2 and 8.0 SEER2 18.3 and 22.0
FUJITSU AIRSTAGE CENTAURI XLTH R32 (AirGreen image)
Example · centralFUJITSU AIRSTAGE

CENTAURI XLTH R32 · 36,000 BTU

AMUH36KUAS / AOUH36KUAH1 · AHRI 217895717

See the product page
FUJITSU AIRSTAGE AQUILA XLTH R32, four zones (AirGreen image)
Example · multi-zoneFUJITSU AIRSTAGE

AQUILA XLTH R32 · 36,000 BTU

AOUH36KWAH4 + wall units · AHRI 215735282

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 36,000 BTU/h (3-ton) house in Montréal, on Hydro-Québec Rate D, taxes included. Both examples are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. The certificates give 36,000 BTU/h of cooling at 35 °C for the central system and 35,200 for the multi-zone (four wall units): the calculation uses their common nominal size, 36,000 BTU/h. Electric baseboards serve as the reference.

How this amount is calculated
  1. Heat to supply over the winter. A house whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, the Montréal design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification ignores the recovery after a temperature setback.
  2. Heating electricity. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup heat expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Cooling electricity. 36,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room reaches its set temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is a way to compare units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.

The house

Ducts that light up, or units that appear room by room

Switch between the two systems. With a central system, a unit in the basement pushes air through the duct network to every connected room. With a multi-zone, tap the rooms you want to equip: each one gets an indoor unit, connected by its own piping to the same outdoor unit.

Illustrated cross-section: the house, the ducts and the piping are a diagram. The units are the real photos of the two FUJITSU AIRSTAGE examples, at the same scale as each other: AMUH36KUAS air handler (21 × 48 in), AOUH36KUAH1 and AOUH36KWAH4 outdoor units (37 × 39 5/16 in each), ASUH12KPAS wall unit (32 13/16 × 10 5/8 in). Four-indoor-unit limit and piping lengths: Aquila brochure FG2057B, rev. 8/2025.

Your answers

Four questions about your house

Answer with your own house in mind: each answer shows what changes for the central system and for the multi-zone. Nothing is ranked, and the estimator’s visit is what confirms what your ducts allow.

Day to day

What living with each one is like

A central system and a multi-zone can heat the same house; they just don’t move through it the same way. The table describes the two examples, based on their documents.

For the homeownerCentral (example)Multi-zone (example)
In the roomsGrilles in the floor, wall or ceilingAn indoor unit in each room served, up to 4
In the basementThe AMUH36KUAS air handler on the duct networkNothing, unless you choose a ducted unit
Temperature settingOne thermostat for all connected roomsOne control per indoor unit
The filterJust one, at the air handler’s returnOne in each indoor unit
Rooms without a unitEvery room connected to the ducts gets the airExisting heating, or air moving through the doorways
The electrical panelPer the manufacturerOutdoor unit: breaker max. 35 A (MCA 33.9 A)Outdoor unit: 35 A breaker (MCA 34.8 A), a single circuit for all 4 rooms

NRCan advises changing or cleaning the air filter every 3 months, and notes that an all-electric air-source heat pump usually requires a 200 A electrical service, and that a panel upgrade may be needed (“Heating and Cooling With a Heat Pump”, modified December 24, 2025).

Extreme cold

Below −15 °C: the two examples, at the same temperatures

NEEP measures both examples at the same temperatures, down to −26.1 °C (−15 °F). Between −15 °C and −26.1 °C nothing is published: the table shows the two values that frame each temperature.

What FUJITSU AIRSTAGE writes below −15 °C. CENTAURI XLTH (submittal sheet 36KUAH1M): heating stated down to −26 °C (−15 °F), with no low-temperature cutoff. AQUILA XLTH (brochure FG2057B): heating from −26 to 24 °C, with a base heater. For both, no capacity is published below −26 °C.
Installation

A duct network, or piping for each room

The units of both examples, at the same scale

Heights and widths published by FUJITSU AIRSTAGE. Grid: 12 in. Both outdoor units have the same published dimensions.

InstallationCentral (example)Multi-zone (example)
Maximum piping length246 ft230 ft total82 ft maximum per indoor unit
Precharged length98 ft164 ft
Maximum height difference98 ft49 ftto the farthest indoor unit; 33 ft between two indoor units
Outdoor unit W × H × D, weight37 × 39 5/16 × 12 5/8 in, 159 lb37 × 39 5/16 × 12 5/8 in, 154 lb
Indoor unit, weightAir handler 21 × 48 × 21 in, 137 lbWall unit ASUH12KPAS 32 13/16 × 10 5/8 × 8 3/4 in, 21 lb
Outdoor unit electrical protectionPer the manufacturerBreaker max. 35 A (MCA 33.9 A)35 A breaker (MCA 34.8 A)
Stated heating / cooling range−26 to 24 °C / −21 to 50 °C−26 to 24 °C / −10 to 50 °C
Number of indoor units12 to 4connectable capacity: 25,000 to 46,000 BTU/h

Sources: FUJITSU AIRSTAGE, submittal sheet 36KUAH1M (version 20260123A) for the central system; Aquila multi-zone brochure FG2057B (rev. 8/2025) for the AOUH36KWAH4 and the ASUH12KPAS wall unit.

Frequently asked questions

Before you choose

Are my current ducts suitable for a heat pump?

Often, but not always: their size, their condition and the airflow the heat pump needs are checked on site, during the estimator’s visit.

Can I keep my baseboards with a multi-zone?

Yes. Rooms without an indoor unit stay heated by their baseboards, and the baseboards in equipped rooms can stay in place as backup.

And a ducted unit in a house without ducts?

It is a middle path: a hidden unit and short ducts for a few neighbouring rooms. The manufacturer of the example lists ducted units among its R-32 multi-zone indoor units, depending on the outdoor unit.

Why compare two FUJITSU AIRSTAGE systems?

To isolate the question of the type of installation: same manufacturer, same XLTH family, same 36,000 BTU nominal capacity, and each with its own AHRI certificate. Other brands have other values; the page ranks neither type.

Does the multi-zone heat as well in extreme cold?

Per NEEP, at −15 °C the central example reaches 41,000 BTU/h and the multi-zone 36,400 BTU/h; at −26.1 °C, 32,000 and 22,140 BTU/h. These values belong to these two combinations; another model will have its own.

Are they eligible for rebates?

NEEP lists both combinations as ENERGY STAR and cold climate. Eligibility depends on the official list in effect on the purchase date and on the combination installed; this page promises no amount.

Certified data

The AHRI and NEEP values of both examples

Certified valueCENTAURI XLTH (central)AQUILA XLTH (multi-zone)
Cooling
Rated capacity at 35 °C36,000 BTU/h35,200 BTU/h
SEER218.322.0
EER211.413.0
Heating, same conditions
HSPF2 Region IV / V10.2 / 8.210.0 / 8.0
8.3 °C: min. / rated / max.BTU/h9,200 / 38,000 / 43,00012,000 / 36,400 / 42,000
8.3 °C: COP at min., rated, max.3.80 / 3.89 / 3.285.41 / 4.30 / 4.04
−8.3 °C: min. / rated / max.BTU/h8,300 / 25,200 / 41,6008,300 / 24,400 / 38,000
−8.3 °C: COP at min., rated, max.3.86 / 2.90 / 2.254.19 / 3.33 / 2.28
−15 °C: min. / rated / max.BTU/h7,900 / 41,000 / 41,0006,800 / 36,400 / 36,400
−15 °C: COP at min., rated, max.3.86 / 1.98 / 1.983.62 / 1.90 / 1.90
−26.1 °C: capacity min. / max.BTU/h6,000 / 32,0004,300 / 22,140
−26.1 °C: COP at min. and max.2.93 / 1.822.52 / 1.66
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP record217895717 · 306746215735282 · 385699
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of a given measure, under the same conditions. It is not a recommendation. Capacities and COPs at each test point are not highlighted: which one is higher changes from point to point. The multi-zone is certified with wall units (“Multizone All Non-Ducted” per NEEP).

Central or multi-zone: both examples are on the AirGreen website.

With or without ducts, we start from your house: bring your current heating type, the condition of your ducts if you have any, the rooms to heat and cool, and your electrical service.

Sources and documents

Where each figure comes from