Replace the furnace, or add a heat pump to it?

Home / Comparisons / Guides by type of system

Guide · Replace or add? · 36,000 BTU examples

Replace the furnace, or add a heat pump to it?

Your house already has a furnace and ducts: two paths lead to a central heat pump. You replace the furnace with a new indoor unit, with its own coil and backup elements. Or you keep the furnace and set a coil on top of it: that is the ADD-ON, and the furnace becomes the backup. To keep it concrete, this guide follows the MIDEA MO1SE-H36B-2A outdoor unit in both setups, each with its own AHRI certificate.

MO1SE-H36B-2A outdoor unit in both HSPF2 V 8.2 and 7.9 SEER2 18.0 and 15.8
MIDEA EVOX G3, 3-ton central heat pump (AirGreen image)
Example · complete replacementMIDEA

EVOX G3 · 36,000 BTU

MAUSE-H36B-2A / MO1SE-H36B-2A · AHRI 215471343

See the product page
MIDEA EVOX G3 ADD-ON, coil and outdoor unit (AirGreen image)
Example · ADD-ON on the furnaceMIDEA

EVOX G3 ADD-ON · 36,000 BTU

MAAHE-H36B-BA / MO1SE-H36B-2A · AHRI 216623524

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 36,000 BTU/h (3-ton) house in Montréal, on Hydro-Québec Rate D, taxes included. Both setups are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. For the ADD-ON, the calculation counts the heat pump and the electric backup provided for in the HSPF2 standard: the switch to the furnace and its fuel are not modelled. Electric baseboards serve as the reference.

How this amount is calculated
  1. Heat to supply over the winter. A house whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, the Montréal design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification ignores the recovery after a temperature setback.
  2. Heating electricity. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup heat expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Cooling electricity. 36,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room reaches its set temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is a way to compare units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise. On Rate DT, the bill follows a different price grid, not calculated here.

The two basements

The same basement, today and after the work

On the left, the furnace goes and a new indoor unit takes its place. On the right, it stays and gets a coil. Pick your furnace, then bring the outdoor temperature down: each basement shows which one heats the house, and what the certified heat pump can deliver at that temperature.

−10 °C
A · Complete replacementEVOX G3 · MAUSE-H36B-2A
B · ADD-ONFurnace kept · MAAHE-H36B-BA coil
DTHydro-Québec Rate DT (dual energy). With a natural gas, oil, propane or wood pellet furnace, an automatic device switches to fuel when it gets colder than −12 °C or −15 °C outside, depending on the region. The probe is supplied and installed by Hydro-Québec, usually built into the meter. The two sources never run at the same time.

Illustrated cross-section: the basement, the ducts, the furnace and the MAUSE-H36B-2A indoor unit are diagrams (no official photo of this unit alone was found). The coil and the outdoor unit are the real photos; everything is at the same scale (widths and heights published by MIDEA; a 21 × 48 in furnace, as an example). The ADD-ON switchover with an electric furnace follows the EVOX coil service manual: S3 threshold adjustable from −30 to 8 °C, compressor locked out below the threshold, allowed again from the threshold + 2 °C; the manual gives no default value, the installer makes the choice. For the complete replacement, the electric elements are the indoor unit’s backup heat kit (up to 25 kW per MIDEA).

Your answers

Your current installation, in four questions

The furnace type, its condition and the space above it weigh heavily on this choice. Tap the answer that matches your basement: you will see what it changes for each of the two paths. Neither path is ranked; what we measure on site counts for more than these four answers.

Day to day

What stays, what gets added

The heat pump outside is the same in both examples. The difference lies in what goes with it in the basement, and in what takes over in extreme cold.

For the homeownerComplete replacement (example)ADD-ON (example)
What stays in placeThe ducts, if their condition allowsThe furnace, its ducts, and its vent or chimney where applicable
What gets added in the basementThe MAUSE-H36B-2A indoor unit, in place of the furnaceThe MAAHE-H36B-BA coil, set on the furnace
Backup heat in extreme coldThe indoor unit’s electric elements (kit up to 25 kW)The existing furnace, electric or fuel-fired
Heat pump and backup at the same timeThe elements supplement the heat pump when neededNo: with the coil’s factory setting, one source at a time; on Rate DT, never at the same time
Hydro-Québec Rate DTNot covered: the house goes all-electricPossible with a gas, oil, propane or pellet furnace, under conditions
The day the furnace gives outAlready settled: it has been replacedIt will need replacing; with oil, not by a fossil-fuel appliance
The control120N (X6W) wall control with Wi-Fi, or a 24 V thermostat from another brand120N (X6W) wall control with Wi-Fi, or a 24 V thermostat from another brand

Sources: MIDEA submittal sheets for both combinations; EVOX coil service manual (SW2-4 switch: “only one” source at a time, default setting); Hydro-Québec, “Rate DT: how it works”; Government of Québec, news release of November 17, 2021 on heating oil.

The rules in Québec

What frames the ADD-ON, in figures

These benchmarks come from Hydro-Québec and the Government of Québec. They don’t say how much you will pay: they say what is allowed and how the system switches over.

−12 or −15 °CBelow this threshold, depending on the region, a Rate DT system switches to fuel; above it, it heats with electricity.Hydro-Québec, Rate DT: how it works
4 fuelsAccepted as backup on Rate DT: natural gas, heating oil, propane, wood pellets. The fuel must be able to heat the house on its own.Hydro-Québec, Rate DT: how it works
200 A, 400 A and upElectrical services eligible for Rate DT; only the 320 A service is excluded.Hydro-Québec, Rate DT: how it works
Dec. 31, 2021End of the installation of oil heating appliances in new buildings.Government of Québec, news release of Nov. 17, 2021
Dec. 31, 2023In existing buildings: end of the installation of oil appliances, and of replacing an oil appliance with a fossil-fuel appliance.Government of Québec, news release of Nov. 17, 2021
20 yearsThe regulation will prohibit repairing oil heating appliances more than 20 years old; the news release does not give the effective date.Government of Québec, news release of Nov. 17, 2021, updated Feb. 15, 2022
Extreme cold

Below −15 °C: the two setups, at the same temperatures

NEEP measures both combinations at the same temperatures, down to −30 °C (−22 °F). NEEP publishes nothing between −15 °C and −30 °C: at −20 and −25 °C, the table gives the range from the −15 °C value to the −30 °C value.

What MIDEA writes below −15 °C. Both submittal sheets state a heating range from −30 to 24 °C. The ADD-ON coil manual adds that the furnace takes over below −30 °C (−22 °F). No capacity is published below −30 °C, for either one.
Installation

A new 58 in unit, or a 23 ½ in coil on the furnace

The units of both examples, at the same scale

Heights and widths published by MIDEA. Grid: 12 in. The MAUSE-H36B-2A indoor unit is drawn (diagram), the others are photos. With the ADD-ON, the coil adds to the height of the existing furnace: there has to be room up to the main duct.

InstallationComplete replacement (example)ADD-ON (example)
Maximum piping length246 ft246 ft
Precharged length25 ft+ 0.7 oz per foot beyond25 ft+ 0.7 oz per foot beyond
Maximum height difference98 ft98 ft
Outdoor unit W × D × H, weight38 9/16 × 16 3/8 × 38 3/8 in, 204 lb38 9/16 × 16 3/8 × 38 3/8 in, 204 lb
Indoor unit, weightMAUSE unit 17 1/2 × 21 1/2 × 58 1/8 in, 149 lbMAAHE coil 17 1/2 × 21 × 23 1/2 in, 59.5 lbon the existing furnace
Electrical protectionPer the manufacturerOutdoor unit: MCA 29 A, MOP 30 A; indoor unit: MCA 6 A, MOP 15 A, without the backup kitOutdoor unit: MCA 29 A, MOP 30 A; the furnace keeps its own supply
Stated heating / cooling range−30 to 24 °C / −30 to 50 °C−30 to 24 °C / −30 to 50 °C

Sources: MIDEA, submittal sheets MAUSE-H36B-2A / MO1SE-H36B-2A and MAAHE-H36B-BA / MO1SE-H36B-2A; EVOX Extreme Heat installation manual, rev. 5 (Oct. 23, 2025) for the maximum length of the complete replacement. The outdoor unit’s sound level is printed as 63 dB(A) on the first sheet and 64 dB(A) on the second.

Frequently asked questions

Before you choose

Who decides the switch to fuel?

On Rate DT, an automatic switching device does, connected to an outdoor temperature probe that Hydro-Québec supplies and installs, usually built into the meter. Hydro-Québec advises against manual switching, unless one of the two sources is faulty.

Can I keep an oil furnace with an ADD-ON?

An existing oil furnace can serve as backup, but the regulation sets limits. According to the Government of Québec news release, since December 31, 2023 it has been prohibited to install an oil appliance in an existing building or to replace one with a fossil-fuel appliance. The regulation will also prohibit repairing oil heating appliances more than 20 years old; the news release does not say from when. Check your furnace’s age before choosing this path.

Must the fuel be able to heat the house on its own?

On Rate DT, yes: Hydro-Québec requires the fuel to supply the needed heat on its own in extreme cold, and does not allow both sources to be used at the same time.

Why do the certified efficiencies differ, with the same outdoor unit?

Because an AHRI certificate covers a complete combination: the outdoor unit and the indoor unit tested together. On one side, the MAUSE-H36B-2A indoor unit; on the other, the MAAHE-H36B-BA coil. The values of one do not carry over to the other.

Are both eligible for rebates?

NEEP lists both combinations as cold-climate heat pumps. The complete combination also carries the ENERGY STAR designation; the ADD-ON combination does not carry it in the NEEP database consulted. Eligibility depends on the official list in effect on the purchase date and on the combination installed; this page promises no amount.

Are my ducts suitable?

In both cases, the existing ducts can be reused if their size and condition allow. With the ADD-ON, there also has to be enough height between the top of the furnace and the main duct for the coil (23 ½ in for the example). These points are checked during the estimator’s free visit.

Certified data

The AHRI and NEEP values of both examples

Certified valueEVOX G3 (complete replacement)EVOX G3 ADD-ON
Cooling
Rated capacity at 35 °C36,000 BTU/h36,000 BTU/h
SEER218.015.8
EER212.010.7
Heating, same conditions
HSPF2 Region IV / V10.0 / 8.29.4 / 7.9
8.3 °C: min. / rated / max.BTU/h11,400 / 37,000 / 47,00011,900 / 38,000 / 46,000
8.3 °C: COP at min., rated, max.4.45 / 3.50 / 3.274.25 / 3.30 / 2.97
−8.3 °C: min. / rated / max.BTU/h11,000 / 33,000 / 41,5009,300 / 29,200 / 39,000
−8.3 °C: COP at min., rated, max.2.58 / 2.50 / 2.212.60 / 2.50 / 2.18
−15 °C: min. / rated / max.BTU/h8,900 / 37,400 / 37,40010,400 / 36,000 / 36,000
−15 °C: COP at min., rated, max.2.16 / 1.90 / 1.901.77 / 1.90 / 1.90
−30 °C: capacity min. / max.BTU/h4,700 / 27,6005,500 / 28,600
−30 °C: COP at min. and max.1.28 / 1.561.25 / 1.61
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesNot listed / Yes
AHRI certificate · NEEP record215471343 · 387396216623524 · 381863
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-454B · GWP 466 · A2LR-454B · GWP 466 · A2L

higher marks the higher value of a given measure, under the same conditions. It is not a recommendation. Capacities and COPs at each test point are not highlighted: which one is higher changes from point to point.

Both setups are on the AirGreen website.

Replace or add: we start with your furnace. Bring its type and age, an idea of the space above it, and your electrical service.