SHARP ZU1 wall heat pump installation in Sainte-Anne-de-Bellevue, compared with the SHARP CHU 18,000 BTU

The Sainte-Anne-de-Bellevue job, an 18,000 BTU SHARP ZU1, and the SHARP CHU series in the same format: AHRI certified values side by side, estimated cost, extreme cold down to −30 °C and installation dimensions.

By AirGreen Climatisation & Chauffage Admin14 min read
SHARP ZU1 wall heat pump installation in Sainte-Anne-de-Bellevue, compared with the SHARP CHU 18,000 BTU
SHARP ZU1 wall heat pump installation in Sainte-Anne-de-Bellevue, compared with the SHARP CHU 18,000 BTU
–chapters in this story
14 minreading time
–type of installation
2024year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job
Project · Sainte-Anne-de-Bellevue · Comparison · Wall unit · 18,000 BTU

SHARP ZU1 and SHARP CHU, 18,000 BTU: the same cabinet, two certificates

In Sainte-Anne-de-Bellevue, on Montréal's West Island, AirGreen put in an 18,000 BTU SHARP ZU1 wall heat pump. SHARP now sells a later series in the same format, the CHU. AirGreen sells both. Here is what stayed the same and what changed, one certified value at a time.

24·25
SEER2, AHRI certificates
9.0·9.0
HSPF2 Region V: the same figure
18,000·19,500
BTU/h maximum at −15 °C, certified
−27.2·−30
°C, coldest certified point
Installed in Sainte-Anne-de-BellevueAirGreen product card for the SHARP ZU1 wall heat pump

SHARP ZU1 18,000 BTU

AY-XP18ZU1 / AE-X18ZU1 · AHRI 213246053

ZU series · R-32See the product page
The next series, same formatAirGreen product card for the SHARP CHU series

SHARP CHU 18,000 BTU

AY-XP18CHU / AE-X18CHU · AHRI 217508925

CHU series · R-32See the product page
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference. Both certificates give the same HSPF2 Region V, 9.0, so winter comes to the same amount with either one; the gap comes from cooling, SEER2 of 24 and 25.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065 ¢ per kWh up to 40 kWh a day, 11.142 ¢ above that; the average price, 9.104 ¢, is the one Hydro-Québec’s calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and how the unit is used; this amount is not a promise.

The job

An 18,000 BTU SHARP ZU1 on the West Island

SHARP indoor unit on the wall, Sainte-Anne-de-Bellevue job
AirGreen photo of the job, published with the original article.

The original article, published on December 27, 2024, describes an 18,000 BTU SHARP ZU1 wall heat pump put in for a homeowner in Sainte-Anne-de-Bellevue. What the client asked for comes down to four points, listed below as the article reports them.

Comfort all year round

Heat in winter and cool in summer with a single heat pump.

Heat in extreme cold

SHARP publishes a heating range of −27 to 24 °C for the ZU series. For comparison, Montréal’s design temperature is −23.1 °C (NRCan, HOT2000).

R-32 refrigerant

Both certificates list it: R-32, class A2L under ASHRAE Standard 34, GWP of 675 per the IPCC Fourth Assessment Report.

A unit eligible for programs

Eligibility is checked against the program’s official list at the time of the application; it can change. This page states no amount.

December 27, 2024AirGreen article: 18,000 BTU SHARP ZU1 put in at Sainte-Anne-de-Bellevue.
January 2026SHARP CHU/CU catalogue, version MNSPLT-CHUCU 1.1.1: the 18,000 BTU CHU, same published cabinet size.
November 17, 2026Both AHRI certificates re-read on NEEP for this page.

Why the CHU across from it? It is the single-zone wall series SHARP publishes after the ZU, at the same 18,000 BTU capacity, and its indoor and outdoor units have exactly the same dimensions and weight as the ZU1’s in SHARP’s documents. So the comparison shows what an owner who already has a ZU1, or who is weighing the two, can check for themselves.

The two-generation game

ZU1, CHU or both? Ten figures, your guess

Both wall units have the same published cabinet: by eye, nothing tells them apart. Each card gives a figure taken from the AHRI certificates or the SHARP documents; say which unit it belongs to. The answer appears with both values and its source.

Certified values: AHRI certificates 213246053 (ZU1) and 217508925 (CHU), NEEP records 507396 and 507387, read on November 17, 2026. Published values: SHARP ZU/ZHU brochure (RBL A/C, undated) and SHARP MNSPLT-CHUCU 1.1.1 catalogue (January 2026). The game picks neither unit: a higher value is not an advantage in itself.

Extreme cold

Below −15 °C: every published value, none invented

The certificates give a point at −15 °C for both, then one last point: −27.2 °C for the ZU1, −30 °C for the CHU. In between, SHARP publishes maximum capacities at −20, −25 and −27 °C in its own documents.

Read this before concluding. At −20, −25 and −27 °C, both values come from the same kind of SHARP document, at the same temperature: they can be compared. At −30 °C, only the CHU has a point; the ZU1 is not rated to heat below −27 °C, and the page says so instead of drawing a bar.
Documented features

What each SHARP document names

Only the features named in the ZU/ZHU brochure or the CHU/CU catalogue are listed. When a document is silent, the page says so: a document’s silence does not prove a feature is missing.

Fan and Coanda airflow
ZU1 “Coanda airflow system with long flap”CHU “Coanda Airflow (LONG)”

Warm or cool air runs along the ceiling instead of blowing on people. Published airflows are identical: 752 cfm at most in heating.

Louvers and air direction
ZU1 horizontal manual, vertical automaticCHU “4-Way Auto Louver”

On the CHU, both directions are set from the remote.

Presence sensor and “Spot Air”
ZU1 reserved for the ZHU series per the brochureCHU “Motion Sensor” and “Spot Air” listed

The sensor finds where people are to direct the air.

Defrost: Hot Gas Pipe
ZU1 “Hot gas pipe system (patented)”CHU “Hot Gas Pipe”

A hot gas line keeps the base of the outdoor unit free of ice, according to SHARP.

Automatic restart
ZU1 “Auto Restart”CHU “Auto Restart”

After a power outage, the unit resumes its last settings.

Operating modes
ZU1 “Multi Space”, “Nature Wing”CHU “Multi Space”, Full Power, 10 °C function, Eco, OD Silent

The CHU’s 10 °C function keeps an empty room above freezing.

Indoor cleaning
ZU1 “Plasmacluster cleaning function (patented)”CHU “After Care”

Both documents name a cycle that dries the inside of the unit after use; no health effect is claimed here.

Sound

Published sound, speed by speed

dB

How to read these figures. A-weighted decibels follow the human ear: the lower the number, the quieter the unit. Each dot is a published fan speed, from “Super high” to “Super low”.

Why this is not a ranking. Both documents give a sound pressure without stating the method or the distance; they come from the same family of SHARP documents, but these values are not what you will measure at home.

Indoor unit, heating

Super high / high / medium / low / super low

Indoor unit, cooling

Only one speed differs: medium.

Measurements taken by each manufacturer with its own method; here, the same manufacturer, the same unstated method. Outdoor unit: 52 dB(A) in heating and cooling for both.

Installation

On the wall and outside, the same dimensions

SHARP publishes the same figures for both indoor units: 41 27/64 in wide (1,052 mm), 12 7/16 in high and 31 lb. The photos below are at the same scale.

Both indoor units, to scale

SHARP ZU1AY-XP18ZU1
SHARP ZU1 indoor unit, cut out
41 27/64 in · 1,052 mm
SHARP CHUAY-XP18CHU
SHARP CHU indoor unit, cut out
41 27/64 in · 1,052 mm

Is your wall wide enough?

48 in
SHARP ZU1
SHARP ZU1 wall heat pump installation in Sainte-Anne-de-Bellevue, compared with the SHARP CHU 18,000 BTU
SHARP CHU
SHARP ZU1 wall heat pump installation in Sainte-Anne-de-Bellevue, compared with the SHARP CHU 18,000 BTU

048 in of wall shown
According to SHARP documentsSHARP ZU1 18,000SHARP CHU 18,000
Maximum piping length66 ft (20 m)ZU/ZHU brochure66 ft (20 m)MNSPLT-CHUCU 1.1.1
Precharged length and top-up25 ft, then 0.16 oz/ftSHARP installation manual, ZU/ZHU/BU series25 ft, then 0.16 oz/ft (15 g/m)MNSPLT-CHUCU 1.1.1
Maximum height difference33 ft (10 m)33 ft (10 m)
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 95 lb33 15/32 × 27 15/16 × 13 in, 95 lb
Indoor unit, weight41 27/64 × 12 7/16 × 9 51/64 in, 31 lb41 27/64 × 12 7/16 × 9 51/64 in, 31 lb
Electrical protection208-230 V, 25 A maximum fuse208-230 V, 25 A maximum fuse
Dehumidification2.4 L/h (5.1 US pints/h)Not published by the manufacturer.Not in catalogue MNSPLT-CHUCU 1.1.1
Stated heating / cooling range−27 to 24 °C / −10 to 46 °C−30 to 24 °C / −10 to 46 °C
Refrigerant and chargeR-32; charge not printed in the brochureR-32; 49 oz (1,390 g)

None of the SHARP documents consulted publishes legible clearances around the outdoor unit; they appear in the installation manual supplied with the unit.

FAQ

Questions about this job and these two SHARP units

Why compare the installed ZU1 with the CHU?

Because the CHU is the single-zone wall series SHARP publishes after the ZU, at the same 18,000 BTU capacity, and AirGreen sells both. This page picks neither: it shows what the certificates and SHARP’s documents say about each one.

Does winter cost less with the CHU?

By our estimate, no: both certificates give an HSPF2 Region V of 9.0, and the method uses that figure. The estimated gap comes from cooling (SEER2 of 24 for the ZU1, 25 for the CHU). The CHU’s higher heating maximums matter mostly in very cold weather, which HSPF2 alone does not sum up.

What does the ZU1 do below −27 °C?

SHARP publishes a heating range of −27 to 24 °C for the ZU series. The last certified point is 11,500 BTU/h at −27.2 °C (−17 °F). SHARP publishes nothing colder for the ZU1; the CHU has a certified point of 11,800 BTU/h at −30 °C.

Do the two units really have the same size?

According to the ZU/ZHU brochure and the CHU/CU catalogue, yes: 41 27/64 × 12 7/16 × 9 51/64 in and 31 lb indoors, 33 15/32 × 27 15/16 × 13 in and 95 lb outdoors, with the same published airflows. The AHRI certificates, on the other hand, are different.

Do the ZU brochure and the ZU1 certificate agree?

The brochure prints models AY-XPC18ZU / AE-X18ZU; AHRI certificate 213246053 covers AY-XP18ZU1 / AE-X18ZU1. At the three temperatures both give (−8.3, −15 and −27 °C), the maximum capacities are identical. The page follows the certificate and takes from the brochure only the points it does not give (−20 and −25 °C) and the physical specifications.

What does “higher” mean in the data table?

The label marks the higher value of the same measure, under the same conditions. It is not a recommendation: depending on the room and how it is used, a higher value may change nothing.

Certified data

Both certificates, line by line

AHRI certificate, via NEEP (Nov. 17, 2026)SHARP ZU1 18,000SHARP CHU 18,000
Identification
AHRI certificate · NEEP record213246053 · 507396217508925 · 507387
Certificate: indoor and outdoor unitsAY-XP18ZU1 / AE-X18ZU1AY-XP18CHU / AE-X18CHU
RefrigerantR-32R-32
ENERGY STARYes, cold climateYes, cold climate
Seasonal efficiencies
SEER22425
EER21313
HSPF2 Region IV1111.5
HSPF2 Region V99
Cooling at 35 °C
Capacity min. / rated / max.6,000 / 18,000 / 21,600 BTU/h6,000 / 18,000 / 21,600 BTU/h
Heating at 8.3 °C
Capacity min. / rated / max.5,500 / 21,600 / 25,600 BTU/h5,500 / 21,600 / 30,000 BTU/h
COP min. / rated / max.5.76 / 4.22 / 3.685.76 / 4.22 / 3.43
Heating at −8.3 °C
Capacity min. / rated / max.7,500 / 22,000 / 22,000 BTU/h7,500 / 22,600 / 22,600 BTU/h
COP min. / rated / max.3.38 / 2.38 / 2.383.38 / 2.28 / 2.28
Heating at −15 °C
Capacity min. / rated / max.5,800 / 18,000 / 18,000 BTU/h5,800 / 19,500 / 19,500 BTU/h
COP min. / rated / max.2.93 / 2.2 / 2.22.93 / 2.2 / 2.2
Coldest point on the certificate
Test temperature−27.2 °C (−17 °F)−30 °C (−22 °F)
Capacity min. / max.3,200 / 11,500 BTU/h2,200 / 11,800 BTU/h
COP min. / max.2.04 / 1.881.5 / 1.8

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. The two coldest points are at different temperatures: they are not marked.

Both are on AirGreen’s website.

An estimate visit lets you measure the room, the wall and the line route before choosing.

Sources

Documents consulted

AHRI certificate 213246053 · NEEP record 507396SHARP AY-XP18ZU1 / AE-X18ZU1, ashp.neep.org, consulted November 17, 2026
AHRI certificate 217508925 · NEEP record 507387SHARP AY-XP18CHU / AE-X18CHU, ashp.neep.org, consulted November 17, 2026
SHARP ZU/ZHU brochure (FR)RBL A/C, no number or date; AY-XPC18ZU / AE-X18ZU column. Consulted November 17, 2026.
SHARP CHU/CU Series catalogueVersion MNSPLT-CHUCU 1.1.1, effective January 2026; AY-XP18CHU column. Consulted November 17, 2026.
SHARP installation manual, ZU/ZHU/BU seriesglobal.sharp, no printed code: precharged length and refrigerant top-up. Consulted November 2026.
Hydro-Québec, Electricity ratesApril 1, 2026, Rate D, sec. 2.5
NRCan, HOT2000 climate dataMontréal Intl: 4,167 degree-days (18 °C base), design temperature −23.1 °C
IPCC, Fourth Assessment Report (2007) · ASHRAE 34100-year GWP of R-32: 675; safety class A2L
The unit

The unit on this job, in figures

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).