SHARP ZU1 18,000 BTU
AY-XP18ZU1 / AE-X18ZU1 · AHRI 213246053
ZU series · R-32See the product pageThe Sainte-Anne-de-Bellevue job, an 18,000 BTU SHARP ZU1, and the SHARP CHU series in the same format: AHRI certified values side by side, estimated cost, extreme cold down to −30 °C and installation dimensions.

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
In Sainte-Anne-de-Bellevue, on Montréal's West Island, AirGreen put in an 18,000 BTU SHARP ZU1 wall heat pump. SHARP now sells a later series in the same format, the CHU. AirGreen sells both. Here is what stayed the same and what changed, one certified value at a time.

AY-XP18ZU1 / AE-X18ZU1 · AHRI 213246053
ZU series · R-32See the product page
AY-XP18CHU / AE-X18CHU · AHRI 217508925
CHU series · R-32See the product pageAirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference. Both certificates give the same HSPF2 Region V, 9.0, so winter comes to the same amount with either one; the gap comes from cooling, SEER2 of 24 and 25.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and how the unit is used; this amount is not a promise.

The original article, published on December 27, 2024, describes an 18,000 BTU SHARP ZU1 wall heat pump put in for a homeowner in Sainte-Anne-de-Bellevue. What the client asked for comes down to four points, listed below as the article reports them.
Heat in winter and cool in summer with a single heat pump.
SHARP publishes a heating range of −27 to 24 °C for the ZU series. For comparison, Montréal’s design temperature is −23.1 °C (NRCan, HOT2000).
Both certificates list it: R-32, class A2L under ASHRAE Standard 34, GWP of 675 per the IPCC Fourth Assessment Report.
Eligibility is checked against the program’s official list at the time of the application; it can change. This page states no amount.
Why the CHU across from it? It is the single-zone wall series SHARP publishes after the ZU, at the same 18,000 BTU capacity, and its indoor and outdoor units have exactly the same dimensions and weight as the ZU1’s in SHARP’s documents. So the comparison shows what an owner who already has a ZU1, or who is weighing the two, can check for themselves.
Both wall units have the same published cabinet: by eye, nothing tells them apart. Each card gives a figure taken from the AHRI certificates or the SHARP documents; say which unit it belongs to. The answer appears with both values and its source.
Certified values: AHRI certificates 213246053 (ZU1) and 217508925 (CHU), NEEP records 507396 and 507387, read on November 17, 2026. Published values: SHARP ZU/ZHU brochure (RBL A/C, undated) and SHARP MNSPLT-CHUCU 1.1.1 catalogue (January 2026). The game picks neither unit: a higher value is not an advantage in itself.
The certificates give a point at −15 °C for both, then one last point: −27.2 °C for the ZU1, −30 °C for the CHU. In between, SHARP publishes maximum capacities at −20, −25 and −27 °C in its own documents.
Only the features named in the ZU/ZHU brochure or the CHU/CU catalogue are listed. When a document is silent, the page says so: a document’s silence does not prove a feature is missing.
Warm or cool air runs along the ceiling instead of blowing on people. Published airflows are identical: 752 cfm at most in heating.
On the CHU, both directions are set from the remote.
The sensor finds where people are to direct the air.
A hot gas line keeps the base of the outdoor unit free of ice, according to SHARP.
After a power outage, the unit resumes its last settings.
The CHU’s 10 °C function keeps an empty room above freezing.
Both documents name a cycle that dries the inside of the unit after use; no health effect is claimed here.
How to read these figures. A-weighted decibels follow the human ear: the lower the number, the quieter the unit. Each dot is a published fan speed, from “Super high” to “Super low”.
Why this is not a ranking. Both documents give a sound pressure without stating the method or the distance; they come from the same family of SHARP documents, but these values are not what you will measure at home.
Super high / high / medium / low / super low
Only one speed differs: medium.
Measurements taken by each manufacturer with its own method; here, the same manufacturer, the same unstated method. Outdoor unit: 52 dB(A) in heating and cooling for both.
SHARP publishes the same figures for both indoor units: 41 27/64 in wide (1,052 mm), 12 7/16 in high and 31 lb. The photos below are at the same scale.




| According to SHARP documents | SHARP ZU1 18,000 | SHARP CHU 18,000 |
|---|---|---|
| Maximum piping length | 66 ft (20 m)ZU/ZHU brochure | 66 ft (20 m)MNSPLT-CHUCU 1.1.1 |
| Precharged length and top-up | 25 ft, then 0.16 oz/ftSHARP installation manual, ZU/ZHU/BU series | 25 ft, then 0.16 oz/ft (15 g/m)MNSPLT-CHUCU 1.1.1 |
| Maximum height difference | 33 ft (10 m) | 33 ft (10 m) |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 95 lb | 33 15/32 × 27 15/16 × 13 in, 95 lb |
| Indoor unit, weight | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb |
| Electrical protection | 208-230 V, 25 A maximum fuse | 208-230 V, 25 A maximum fuse |
| Dehumidification | 2.4 L/h (5.1 US pints/h) | Not published by the manufacturer.Not in catalogue MNSPLT-CHUCU 1.1.1 |
| Stated heating / cooling range | −27 to 24 °C / −10 to 46 °C | −30 to 24 °C / −10 to 46 °C |
| Refrigerant and charge | R-32; charge not printed in the brochure | R-32; 49 oz (1,390 g) |
None of the SHARP documents consulted publishes legible clearances around the outdoor unit; they appear in the installation manual supplied with the unit.
Because the CHU is the single-zone wall series SHARP publishes after the ZU, at the same 18,000 BTU capacity, and AirGreen sells both. This page picks neither: it shows what the certificates and SHARP’s documents say about each one.
By our estimate, no: both certificates give an HSPF2 Region V of 9.0, and the method uses that figure. The estimated gap comes from cooling (SEER2 of 24 for the ZU1, 25 for the CHU). The CHU’s higher heating maximums matter mostly in very cold weather, which HSPF2 alone does not sum up.
SHARP publishes a heating range of −27 to 24 °C for the ZU series. The last certified point is 11,500 BTU/h at −27.2 °C (−17 °F). SHARP publishes nothing colder for the ZU1; the CHU has a certified point of 11,800 BTU/h at −30 °C.
According to the ZU/ZHU brochure and the CHU/CU catalogue, yes: 41 27/64 × 12 7/16 × 9 51/64 in and 31 lb indoors, 33 15/32 × 27 15/16 × 13 in and 95 lb outdoors, with the same published airflows. The AHRI certificates, on the other hand, are different.
The brochure prints models AY-XPC18ZU / AE-X18ZU; AHRI certificate 213246053 covers AY-XP18ZU1 / AE-X18ZU1. At the three temperatures both give (−8.3, −15 and −27 °C), the maximum capacities are identical. The page follows the certificate and takes from the brochure only the points it does not give (−20 and −25 °C) and the physical specifications.
The label marks the higher value of the same measure, under the same conditions. It is not a recommendation: depending on the room and how it is used, a higher value may change nothing.
| AHRI certificate, via NEEP (Nov. 17, 2026) | SHARP ZU1 18,000 | SHARP CHU 18,000 |
|---|---|---|
| Identification | ||
| AHRI certificate · NEEP record | 213246053 · 507396 | 217508925 · 507387 |
| Certificate: indoor and outdoor units | AY-XP18ZU1 / AE-X18ZU1 | AY-XP18CHU / AE-X18CHU |
| Refrigerant | R-32 | R-32 |
| ENERGY STAR | Yes, cold climate | Yes, cold climate |
| Seasonal efficiencies | ||
| SEER2 | 24 | 25 |
| EER2 | 13 | 13 |
| HSPF2 Region IV | 11 | 11.5 |
| HSPF2 Region V | 9 | 9 |
| Cooling at 35 °C | ||
| Capacity min. / rated / max. | 6,000 / 18,000 / 21,600 BTU/h | 6,000 / 18,000 / 21,600 BTU/h |
| Heating at 8.3 °C | ||
| Capacity min. / rated / max. | 5,500 / 21,600 / 25,600 BTU/h | 5,500 / 21,600 / 30,000 BTU/h |
| COP min. / rated / max. | 5.76 / 4.22 / 3.68 | 5.76 / 4.22 / 3.43 |
| Heating at −8.3 °C | ||
| Capacity min. / rated / max. | 7,500 / 22,000 / 22,000 BTU/h | 7,500 / 22,600 / 22,600 BTU/h |
| COP min. / rated / max. | 3.38 / 2.38 / 2.38 | 3.38 / 2.28 / 2.28 |
| Heating at −15 °C | ||
| Capacity min. / rated / max. | 5,800 / 18,000 / 18,000 BTU/h | 5,800 / 19,500 / 19,500 BTU/h |
| COP min. / rated / max. | 2.93 / 2.2 / 2.2 | 2.93 / 2.2 / 2.2 |
| Coldest point on the certificate | ||
| Test temperature | −27.2 °C (−17 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 3,200 / 11,500 BTU/h | 2,200 / 11,800 BTU/h |
| COP min. / max. | 2.04 / 1.88 | 1.5 / 1.8 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. The two coldest points are at different temperatures: they are not marked.
An estimate visit lets you measure the room, the wall and the line route before choosing.
Data verified on November 17, 2026. Certified values come from the AHRI certificates published by NEEP; declared values come from the SHARP documents cited. A value published “according to the manufacturer” is not part of the certificate. Cost estimate: AirGreen method v1.1, described above.
Trademarks. SHARP, Plasmacluster and the model names belong to their owners. Logos and images are used only to identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by SHARP.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Flip each card to see what we do instead.
Three habits per season for this unit. They take a few minutes and prevent many calls.
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).