SHARP CU R32 and SHARP CHU R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · Wall-mounted heat pump · 12,000 BTU

SHARP CU and SHARP CHU R32, 12,000 BTU: the extra heat, degree by degree

Same brand, same R32 refrigerant, same outdoor unit size, same HSPF2. The difference shows in maximum heat: at every published temperature, the CHU delivers more than the CU, and it heats down to −30 °C. This page measures that gap, decodes the model names and shows how much wall each one takes up.

HSPF2 Region V: 9.0 for both Max. capacity at −15 °C: 12,700 and 16,000 BTU/h Coldest certified point: −27.2 °C and −30 °C Wall unit width: 879 and 1,052 mm
SHARP CU series 12,000 BTU, indoor unit, outdoor unit and remote control
SHARP

CU R32 series, 12,000 BTU

Ind. AY-XPC12CU · Outd. AE-X12CU
AHRI 217512740

Per SHARP: heating from −27 to 24 °C; two-direction automatic louvers.

See the product page

BTU/h more for the CHU at −15 °C, according to both AHRI certificates.

SHARP CHU series 12,000 BTU, indoor unit, outdoor unit and remote control
SHARP

CHU R32 series, 12,000 BTU

Ind. AY-XP12CHU · Outd. AE-X12CHU
AHRI 217512736

Per SHARP: heating from −30 to 24 °C; presence sensor, Spot Air and four-direction louvers.

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Both certificates give the same HSPF2 Region V (9.0), so winter costs the same amount in this calculation. The difference comes from cooling, where the SEER2 is 22.0 for the CU and 25.0 for the CHU. This calculation covers a 12,000 BTU/h zone; it does not take into account the maximum heat each unit can deliver, which is the subject of the next section.

The extra heat

From 8.3 °C to −30 °C, the gap in maximum heat between the CU and the CHU

The two curves connect the maximum heating capacity published for each series, from the AHRI certificate (circles) or the SHARP sheet’s heating table (diamonds). The red band between them is the extra heat the CHU delivers. Slide to read the gap at each published temperature.

−15 °C
AHRI certificate, via NEEPheating table, SHARP sheetCHU’s extra heat

Maximum capacities are measured under test conditions, at a fixed outdoor temperature. Between two published points, the line only shows the order of magnitude: nothing is published between them.

Model names

AY-XPC12CU or AY-XP12CHU: what SHARP’s documents say about each part of the name

Tap a part of a model number. We state only what the SHARP sheet (January 2026) and the AHRI certificates allow us to say; when SHARP does not define a letter, that is stated as is.

Extreme cold

Below −15 °C: every published value, none invented

The certificates publish a point at −27.2 °C for the CU and at −30 °C for the CHU. In between, the SHARP sheet gives a heating table at −20, −25 and −27 °C. SHARP states that the AE-X12CU outdoor unit does not operate below −17 °F (−27 °C).

Two sources, same figures at both ends. At −15 °C and at the coldest point, the SHARP sheet’s table gives exactly the maximum capacities from the AHRI certificate (12,700 and 8,000 BTU/h for the CU, 16,000 and 9,700 BTU/h for the CHU). The values at −20, −25 and −27 °C come from the sheet only.
Features

What the SHARP sheet assigns to each series

A single SHARP sheet describes both series. Most features are shared; three concern air distribution and are listed only for the CHU.

Presence sensor

CUNot offered on the CU, per the sheet.

CHU“Motion Sensor”.

SHARP, CHU / CU sheet, January 2026

“Spot Air” targeted airflow

CUNot offered on the CU, per the sheet.

CHU“Spot Air”.

SHARP, CHU / CU sheet

Automatic louvers

CUTwo directions.

CHUFour directions.

SHARP, CHU / CU sheet

Coanda effect and “Multi Space”

CUYes, both.

CHUYes, both.

SHARP, CHU / CU sheet

“Full Power” maximum output

CUYes.

CHUYes.

SHARP, CHU / CU sheet

Frost protection at 10 °C

CU50 °F (10 °C) function.

CHU50 °F (10 °C) function.

SHARP, CHU / CU sheet

Eco and “After Care” modes

CUYes, both.

CHUYes, both.

SHARP, CHU / CU sheet

Outdoor quiet mode

CU“OD Silent”.

CHU“OD Silent”.

SHARP, CHU / CU sheet

Hot-gas defrost

CU“Hot Gas Pipe”.

CHU“Hot Gas Pipe”.

SHARP, CHU / CU sheet

Automatic restart

CUYes; 24 h timers and 1, 2, 3 or 5 h.

CHUYes; 24 h timers and 1, 2, 3 or 5 h.

SHARP, CHU / CU sheet

Wi-Fi and app

CUNot listed among the 12,000 BTU model’s features.

CHUNot listed among the 12,000 BTU model’s features.

SHARP, CHU / CU sheet: the SHARP AIR app is described there in general terms

Quiet

Indoor unit sound in heating, speed by speed

The SHARP sheet publishes, in a single table, the sound level of each series at five fan speeds, in heating and in cooling. Here are the heating values, from the lowest speed to the highest.

dB

How to read these figures. A lower dB(A) means a quieter unit. Each point is a published speed; the band connects the lowest to the highest.

What the sheet does not say. The measurement distance and method are not stated, and the speeds are not named. Both series do, however, appear in the same table from the same manufacturer.

Indoor unit, heating

dB per the SHARP sheet, from the lowest speed to the highest

Method not stated by SHARP: different method — not comparable with other brands. Outdoors, the sheet gives 50 dB in heating and 49 dB in cooling for both outdoor units.

The installation

Same outdoor unit size, wall units of different widths

According to SHARP, both outdoor units have the same dimensions. The CHU’s wall unit is 173 mm wider, taller and heavier. Slide to set your wall’s free width.

1,000 mm

Manufacturers also require a clearance around the unit; see the installation guide provided with the quote. Wall units drawn from the dimensions published by SHARP.

Installation, per SHARPSHARP CU R32SHARP CHU R32
Indoor unit W × H × D, weight879 × 289 × 229 mm, 10 kg34-39/64 × 11-3/8 × 9-1/64 in, 22 lb1,052 × 316 × 249 mm, 14 kg41-27/64 × 12-7/16 × 9-51/64 in, 31 lb
Outdoor unit W × H × D, weight780 × 540 × 269 mm, 30 kg780 × 540 × 269 mm, 30 kg
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Piping lengthStandard 3 to 7.6 m; maximum 20 m10 to 25 ft; 66 ft; 15 g of refrigerant per added metreStandard 3 to 7.6 m; maximum 20 m10 to 25 ft; 66 ft; 15 g of refrigerant per added metre
Maximum height difference10 m (33 ft)10 m (33 ft)
Refrigerant and chargeR32, 940 g (33.2 oz)R32, 1,020 g (36 oz)
Electrical protection208/230 V; maximum fuse 15 A208/230 V; maximum fuse 20 A
Indoor airflow, maximum speed438 CFMin heating636 CFMin heating
Rated heating / cooling range−27 to 24 °C / −10 to 46 °C−30 to 24 °C / −10 to 46 °C

Source: SHARP, “CHU / CU” sheet, version MNSPLT-CHUCU 1.1.1, in effect January 2026 (in English), consulted November 9, 2026.

Questions

What we get asked about these two SHARP units

Why is the winter estimate the same?

Because our calculation uses the certificate’s HSPF2 Region V, which is 9.0 for both. Summer differs a little: SEER2 of 22.0 for the CU and 25.0 for the CHU.

How much more heat for the CHU?

According to the AHRI certificates, the CHU’s maximum capacity exceeds the CU’s by 3,850 BTU/h at 8.3 °C, 3,900 BTU/h at −8.3 °C and 3,300 BTU/h at −15 °C. According to the SHARP sheet’s table, the gap is 3,100 BTU/h at −20 °C, 2,600 BTU/h at −25 °C and 3,200 BTU/h at −27 °C.

What does the CU do below −27 °C?

SHARP states that the AE-X12CU outdoor unit does not operate below −17 °F (−27 °C). Its certificate publishes 8,000 BTU/h maximum at −27.2 °C. The CHU is rated down to −30 °C, with 9,700 BTU/h maximum according to its certificate.

What do “CU” and “CHU” mean?

The SHARP sheet does not define these letters. It uses them as series names, and reserves the presence sensor and “Spot Air” airflow for the CHU.

Which one is quieter indoors?

In heating, the sheet gives 23 to 43 dB for the CU and 22 to 44 dB for the CHU, without stating the distance or the measurement method. The published differences are one decibel at most at each speed.

Do they have Wi-Fi?

The SHARP sheet consulted describes the SHARP AIR app, but does not list Wi-Fi among the features of the 12,000 BTU models. We can check this with the distributor before you buy.

What about the warranty?

This page does not compare warranties. The manufacturer’s warranty documents are provided with the quote.

Certified record

The AHRI certificate values, as published

Certified value (AHRI, via NEEP)SHARP CU R32SHARP CHU R32
Seasonal efficiency
SEER222.025.0
EER212.516.0
HSPF2 Region IV11.011.0
HSPF2 Region V9.09.0
Rated capacity at 35 °C12,000 BTU/h12,000 BTU/h
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.3,200 / 14,000 / 19,000 BTU/h3,100 / 16,000 / 22,850 BTU/h
Maximum capacity19,000 BTU/h22,850 BTU/h
COP min. / rated / max.6.25 / 3.98 / 3.095.68 / 4.26 / 3.17
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.3,800 / 15,000 / 15,000 BTU/h5,000 / 18,900 / 18,900 BTU/h
Maximum capacity15,000 BTU/h18,900 BTU/h
COP min. / rated / max.3.48 / 2.44 / 2.442.93 / 2.22 / 2.22
Heating at −15 °C (5 °F)
Capacity min. / rated / max.2,950 / 12,700 / 12,700 BTU/h3,850 / 16,000 / 16,000 BTU/h
Maximum capacity12,700 BTU/h16,000 BTU/h
COP min. / rated / max.2.88 / 2.10 / 2.102.35 / 2.10 / 2.10
Coldest published point
Test temperature−27.2 °C (−17 °F)−30 °C (−22 °F)
Capacity min. and max.1,500 and 8,000 BTU/h1,350 and 9,700 BTU/h
COP min. and max.1.69 and 1.781.07 and 1.80
Certificates
Certificate: indoor and outdoor unitsAY-XPC12CU and AE-X12CUAY-XP12CHU and AE-X12CHU
RefrigerantR32GWP 675 (IPCC, AR4); class A2L (ASHRAE 34)R32GWP 675 (IPCC, AR4); class A2L (ASHRAE 34)
ENERGY STAR and cold climateYes; cold climate: yesper NEEP, Nov. 9, 2026Yes; cold climate: yesper NEEP, Nov. 9, 2026
AHRI certificate · NEEP record217512740 · record 507382217512736 · record 507383

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. The coldest published points are not at the same temperature: they cannot be compared with each other.

Both SHARP units are on the AirGreen website.

A question about either one, or about the installation in your home? Talk to our team.

Sources

Documents consulted

AHRI certificate 217512740 · NEEP, record 507382SHARP AY-XPC12CU / AE-X12CU (CU series). Consulted November 9, 2026.
AHRI certificate 217512736 · NEEP, record 507383SHARP AY-XP12CHU / AE-X12CHU (CHU series). Consulted November 9, 2026.
SHARP, “CHU / CU” sheet, MNSPLT-CHUCU 1.1.1In effect January 2026, in English. Heating table, sound, airflow, dimensions, piping, features. Consulted November 9, 2026.
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5. Consulted November 9, 2026.
NRCan, HOT2000 climate map, Montréal IntlHeating degree-days base 18 °C and design temperature. Consulted November 9, 2026.