DURASTAR Standard R454B and DURASTAR Sirius Heat R454B, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · Wall-mounted heat pump · 12,000 BTU

DURASTAR Standard R454B and Sirius Heat R454B: same indoor unit, two outdoor units

Indoors, the same DRAW12F2A wall unit. Outside, two different outdoor units, and two AHRI certificates. One gets the higher seasonal heating efficiency of the two; the other publishes more maximum heat at every cold temperature and heats down to −30 °C. This page shows where each gap lies, and how many days per winter it comes into play in Montréal.

Indoor unit: DRAW12F2A for both HSPF2 Region V: 8.5 and 8.0 Max. capacity at −15 °C: 8,600 and 11,500 BTU/h Rated heating down to: −25 °C and −30 °C
DURASTAR Standard R454B 12,000 BTU, indoor unit, outdoor unit and remote control
DURASTAR

Standard R454B, 12,000 BTU

Ind. DRAW12F2A · Outd. DRA1U12S2A
AHRI 215359277

DRA1U12S2A outdoor unit: 30-1/8 in wide and 62.2 lb per DURASTAR. Heating rated from −25 to 24 °C.

See the product page
DRAW12F2A DRA1U12S2A DRA1H12S2A

One indoor unit, two outdoor units, two separate AHRI certificates.

DURASTAR Sirius Heat R454B 12,000 BTU, indoor unit, outdoor unit and remote control
DURASTAR

Sirius Heat R454B, 12,000 BTU

Ind. DRAW12F2A · Outd. DRA1H12S2A
AHRI 215359252

DRA1H12S2A outdoor unit: 31-11/16 in wide and 72.8 lb per DURASTAR. Heating rated from −30 to 24 °C.

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The certificate’s HSPF2 Region V is 8.5 for the Standard and 8.0 for the Sirius Heat, so the winter estimate is lower for the Standard. In cooling it is the reverse, since the SEER2 is 23.1 and 24.0. The HSPF2 sums up a whole season; it does not say how much heat each unit can deliver on the coldest days. The next section shows that.

Winter in Montréal, day by day

How many truly cold days per winter, and the heat published for each of those days

Thirty years of Environment and Climate Change Canada records at Montréal–Trudeau airport (1991–2020), sorted by the lowest temperature of each day. Slide toward the cold: the chart counts the days, and the panel shows the maximum heating capacity published for each unit at that temperature.

Days per year, by the day’s minimum

1991–2020 average, ECCC stations 7025250 and 702S006

0100 days200 days
−15 °C
−8.3 °C−15−20−25−30 °C

How to read this chart. The day’s minimum is often reached at night, for only a few hours; published capacities are measured under test conditions, at a fixed outdoor temperature. A day counted at −20 °C is therefore not a full day at −20 °C. Days with no record (0.9% of the period) are not counted. The lowest minimum in the thirty years is −31.8 °C, on January 27, 1994.

Heat and efficiency

More maximum heat on one side, more heat per kWh on the other

At the three temperatures where the AHRI certificate publishes complete values, two measures tell the whole story of this page. On the left, the maximum heat each unit can deliver. On the right, the rated COP: the heat obtained for each unit of electricity.

Maximum heating capacity

BTU/h, AHRI certificate via NEEP

Rated COP

Heat delivered ÷ electricity used, AHRI certificate via NEEP

DURASTAR Standard R454BDURASTAR Sirius Heat R454B

Rated COP is measured at each unit’s rated capacity, which is not the same in cold weather: at −15 °C, 8,600 BTU/h for the Standard and 11,500 BTU/h for the Sirius Heat. The two COPs are therefore read together with their respective capacity. The HSPF2, further up, sums up the whole season.

Extreme cold

Below −15 °C: every published value, none invented

The Standard’s certificate publishes a point at −25 °C, its rated heating limit. The Sirius Heat’s publishes a point at −30 °C, and the DURASTAR submittal sheet adds a value at −25 °C. Where a value is missing, the table shows the range between the two published values on either side.

Two sources for the Sirius Heat at −30 °C. The AHRI certificate (via NEEP) gives 5,900 BTU/h maximum; the DURASTAR submittal sheet (form V1.2_0325) gives 5,800 BTU/h. We show both; in any direct comparison, the certificate prevails.
Features

Two DURASTAR sheets, feature by feature

Only what appears in both DURASTAR submittal sheets. Nine features out of ten are described in the same terms; the difference concerns the lowest rated temperature. When a sheet does not mention a feature, that is stated as is.

Heating in extreme cold

StandardLow-ambient heating and cooling down to −13 °F (−25 °C).

Sirius HeatLow-ambient heating and cooling down to −22 °F (−30 °C); “up to 100% heating capacity at 0 °F”, with no figure at that temperature.

DURASTAR, submittal sheets V1.1_0125 and V1.2_0325

Heated base pan

StandardBase pan heater included.

Sirius HeatBase pan heater included.

DURASTAR, submittal sheets

Refrigerant leak detection

StandardDetection system for A2L refrigerant.

Sirius HeatDetection system for A2L refrigerant.

DURASTAR, submittal sheets

Remote control with “Follow Me” sensor

StandardWireless remote control with “Follow Me”.

Sirius HeatWireless remote control with “Follow Me”.

DURASTAR, submittal sheets

Wired wall thermostat

StandardCompatible with the DRSTAT101 wired thermostat.

Sirius HeatCompatible with the DRSTAT101 wired thermostat.

DURASTAR, submittal sheets

Operating modes

StandardTurbo, ECO, Active Clean and Sleep modes.

Sirius HeatTurbo, ECO, Active Clean and Sleep modes.

DURASTAR, submittal sheets

Automatic restart

StandardAutomatic restart (“Auto restart”).

Sirius HeatAutomatic restart (“Auto restart”).

DURASTAR, submittal sheets

Frost protection at 8 °C

StandardFreeze protection at 46 °F (8 °C).

Sirius HeatFreeze protection at 46 °F (8 °C).

DURASTAR, submittal sheets

Fin coating

Standard“Golden Fin” anti-corrosion coating.

Sirius Heat“Golden Fin” anti-corrosion coating.

DURASTAR, submittal sheets

Wi-Fi and app

StandardNot published in the submittal sheet consulted.

Sirius HeatNot published in the submittal sheet consulted.

DURASTAR, submittal sheets V1.1_0125 and V1.2_0325

Quiet

Indoor unit sound, per each sheet

Both DURASTAR sheets publish a sound level for each speed of the same DRAW12F2A indoor unit. Yet the figures are not the same from one sheet to the other. Here they are, each as published.

dB

How to read these figures. A lower dB(A) means a quieter unit. Each point is a published speed; the band connects the lowest to the highest.

Why this is not a ranking. Neither sheet states the measurement distance or method, and they are not from the same edition (V1.1_0125 and V1.2_0325). The Standard’s sheet also publishes a Turbo speed; the Sirius Heat’s does not.

DRAW12F2A indoor unit

dB(A) per each DURASTAR sheet, from lowest to highest

Method not stated in either sheet: different method — not comparable. Outdoors, the Standard’s sheet publishes 54 dB(A) for the DRA1U12S2A, and the Sirius Heat’s 56 dB(A) for the DRA1H12S2A, a single value each.

The installation

The same indoor wall, two footprints outside

Indoors, nothing changes: same unit, same piping diameters, same precharged length. Outside, the Sirius Heat’s unit is wider, deeper and heavier, according to the dimensions published by DURASTAR.

DURASTAR DRAW12F2A indoor unit, shared by both pairs
31-9/16 in (31.56 in)

DRAW12F2A indoor unit, for both

31.56 × 11.63 × 7.88 in, 19 lb, according to both DURASTAR submittal sheets. Choosing one pair or the other therefore changes neither the wall space to plan for nor the look in the room.

Maximum published airflow: 383 CFM (Turbo speed) in both sheets.

Outdoor units, at the same scale

Front view and side view, from the dimensions published by DURASTAR

Diagram drawn from the published dimensions, not a photo: the grille and panels are indicative.

Installation, per each DURASTAR sheetDURASTAR Standard R454BDURASTAR Sirius Heat R454B
Outdoor unit W × H × D, weight30.13 × 21.88 × 11.94 in, 62.2 lb31.69 × 21.81 × 13 in, 72.8 lb
Indoor unit W × H × D, weight31.56 × 11.63 × 7.88 in, 19 lb31.56 × 11.63 × 7.88 in, 19 lb
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Precharged length25 ft25 ft
Piping length min. – max.10 – 82 ft0.16 oz of refrigerant per foot beyond 25 ft10 – 82 ft0.16 oz of refrigerant per foot beyond 25 ft
Maximum height difference49 ft49 ft
Electrical protectionMinimum circuit ampacity 12 A, 15 A breakerMinimum circuit ampacity 15 A, 15 A breaker
Dehumidification1.3 L/h66 pints per day1.4 L/h71 pints per day
Rated heating / cooling range−25 to 24 °C / −25 to 50 °C−30 to 24 °C / −30 to 50 °C

Sources: DURASTAR, submittal sheets DRAW12F2A / DRA1U12S2A (form V1.1_0125) and DRAW12F2A / DRA1H12S2A (form V1.2_0325), consulted November 9, 2026. Fractions converted to decimal inches (31-9/16 in = 31.56 in; 11-15/16 in = 11.94 in).

Questions

What we get asked about these two DURASTAR units

Is it really the same indoor unit?

Yes. Both AHRI certificates (215359277 and 215359252) and both DURASTAR sheets name the same indoor unit, DRAW12F2A, with the same dimensions and the same weight. It is the outdoor units that differ: DRA1U12S2A for the Standard, DRA1H12S2A for the Sirius Heat.

Why is the winter estimate lower for the Standard?

Because our calculation uses the certificate’s HSPF2 Region V: 8.5 for the Standard, 8.0 for the Sirius Heat. At −8.3 °C and −15 °C, the Standard’s certificate also publishes a higher rated COP, measured at a lower rated capacity than the Sirius Heat’s.

And the very cold days?

At −15 °C, the certificate publishes a maximum capacity of 8,600 BTU/h for the Standard and 11,500 BTU/h for the Sirius Heat. In Montréal, from 1991 to 2020, the day’s minimum reached −15 °C or lower 31.9 days a year on average, and −20 °C or lower 12.1 days.

What does the Standard do below −25 °C?

DURASTAR rates a heating range of −25 to 24 °C for the Standard and publishes no figure below that. In Montréal, from 1991 to 2020, the day’s minimum dropped to −25 °C or lower 2.5 days a year on average. The Sirius Heat is rated down to −30 °C, with 5,900 BTU/h maximum according to its certificate.

Why two figures for the Standard at −8.3 °C?

The AHRI certificate published by NEEP gives a rated and maximum capacity of 10,400 BTU/h at −8.3 °C (17 °F); DURASTAR submittal sheet V1.1_0125 states 9,600 BTU/h. The certificate prevails in any direct comparison; its value is the one we use.

Which one is quieter indoors?

The documents do not allow us to say. The indoor unit is the same, but the two sheets publish different figures (19 to 46 dB(A) and 20 to 40 dB(A)), without stating the distance or the method.

Do they have Wi-Fi?

The two submittal sheets consulted do not mention it. They mention a wireless remote control with “Follow Me” and compatibility with the DRSTAT101 wired thermostat.

What about the warranty?

This page does not compare warranties. The manufacturer’s warranty documents are provided with the quote.

Certified record

The AHRI certificate values, as published

Certified value (AHRI, via NEEP)DURASTAR Standard R454BDURASTAR Sirius Heat R454B
Seasonal efficiency
SEER223.124.0
EER212.213.2
HSPF2 Region IV11.510.5
HSPF2 Region V8.58.0
Rated capacity at 35 °C12,000 BTU/h12,000 BTU/h
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.4,100 / 12,000 / 14,400 BTU/h3,800 / 12,000 / 16,000 BTU/h
Maximum capacity14,400 BTU/h16,000 BTU/h
COP min. / rated / max.5.22 / 3.66 / 3.274.84 / 3.63 / 3.35
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.3,500 / 10,400 / 10,400 BTU/h5,200 / 12,000 / 12,800 BTU/h
Maximum capacity10,400 BTU/h12,800 BTU/h
COP min. / rated / max.2.63 / 2.85 / 2.852.34 / 2.44 / 1.75
Heating at −15 °C (5 °F)
Capacity min. / rated / max.1,900 / 8,600 / 8,600 BTU/h4,000 / 11,500 / 11,500 BTU/h
Maximum capacity8,600 BTU/h11,500 BTU/h
COP min. / rated / max.1.86 / 2.36 / 2.361.80 / 1.80 / 1.80
Coldest published point
Test temperature−25 °C (−13 °F)−30 °C (−22 °F)
Capacity min. and max.800 and 5,300 BTU/h2,000 and 5,900 BTU/h
COP min. and max.0.84 and 1.61.07 and 1.25
Certificates
Certificate: indoor and outdoor unitsDRAW12F2A and DRA1U12S2ADRAW12F2A and DRA1H12S2A
RefrigerantR-454BGWP 466 (IPCC, AR4); class A2L (ASHRAE 34)R-454BGWP 466 (IPCC, AR4); class A2L (ASHRAE 34)
ENERGY STAR and cold climateYes; cold climate: yesper NEEP, Nov. 9, 2026Yes; cold climate: yesENERGY STAR directory, Nov. 9, 2026
AHRI certificate · NEEP record215359277 · record 389493215359252 · record 389518

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. The coldest published points are not at the same temperature: they cannot be compared with each other.

Both DURASTAR units are on the AirGreen website.

A question about either one, or about the installation in your home? Talk to our team.

Sources

Documents consulted

AHRI certificate 215359277 · NEEP, record 389493DURASTAR DRAW12F2A / DRA1U12S2A, DRA series (Standard). Consulted November 9, 2026.
AHRI certificate 215359252 · NEEP, record 389518DURASTAR DRAW12F2A / DRA1H12S2A, DRA series (Sirius Heat). Consulted November 9, 2026.
DURASTAR, submittal sheet DRAW12F2A / DRA1U12S2AForm V1.1_0125 (copy hosted by a distributor). Capacities, operating range, sound, dimensions, piping, features. Consulted November 9, 2026.
DURASTAR, submittal sheet DRAW12F2A / DRA1H12S2AForm V1.2_0325 (copy hosted by a distributor). Capacities, sound, dimensions, piping, features. Consulted November 9, 2026.
ENERGY STAR directory, heat pumpsDRA1H12S2A (ID 3621148, certified May 6, 2026): cold climate, yes. Consulted November 9, 2026.
Environment and Climate Change Canada, daily dataMontréal–Trudeau, stations 7025250 and 702S006, daily minimum temperatures from January 1, 1991 to December 31, 2020 (10,862 days, 99.1% of the period). AirGreen compilation, November 9, 2026.
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5. Consulted November 9, 2026.
NRCan, HOT2000 climate map, Montréal IntlHeating degree-days base 18 °C and design temperature. Consulted November 9, 2026.