Home / Comparisons / 12,000 BTU wall-mounted heat pumps
DIRECT AIR DA25 (R-410A) and HEAT XTREME PRO R-454B: one brand, two refrigerants
Two 12,000 BTU/h DIRECT AIR wall units. The DA25 uses R-410A, the HEAT XTREME PRO uses R-454B. Their AHRI certificates are not quite alike: close efficiencies, but not the same heat in extreme cold. Here is what each certificate says, what DIRECT AIR publishes, and where each refrigerant stands in Canadian regulations.
DA25 R-410A, 12,000 BTU
AHRI 207743720
DIRECT AIR DA25 brochure (2023): heating rated down to −25 °C; ENERGY STAR, without the cold-climate label according to NEEP.
See the product pageSame brand, two refrigerant generations, two AHRI certificates.
HEAT XTREME PRO R-454B, 12,000 BTU
AHRI 216571373
Same AHRI and NEEP certified values as: SENVILLE AURA R454B, MIDEA MIDEA28 and BOSCH Climate 5000 MAX PERFORMANCE R-454B, in 12,000 BTU. Checked in NEEP on November 9, 2026.
See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.
How this amount is calculated
- Heat to deliver over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
The certified seasonal efficiencies are very close: HSPF2 Region V of 8.1 for the DA25 and 8.0 for the HEAT XTREME PRO, SEER2 of 24.6 and 25.4. So are the two estimates. Where the certificates really diverge is on maximum heat in cold weather, further down this page.
Three refrigerants, forty years of Canadian rules
The DA25 and the HEAT XTREME PRO belong to two refrigerant generations. Before 2010, a new unit could still use R-22. Scroll through the dates: each one links to the official text or the body that published it.
GWP: 100-year global warming potential, IPCC Fourth Assessment Report (AR4), the basis used by the Canadian HFC regulations. ODP: ozone depletion potential (Montreal Protocol). Safety classes per the ASHRAE 34 standard. These figures describe the refrigerants, not the units’ consumption or efficiency.
What ENERGY STAR’s “cold climate” label measures
Both pairs are ENERGY STAR certified. According to NEEP, only the HEAT XTREME PRO R-454B also carries the cold-climate label. That criterion requires, among other things, at −15 °C (5 °F), at least 70% of the rated heating capacity at 8.3 °C, with a COP of at least 1.75. Here is where each certificate stands on those two measures.
AirGreen calculation from the AHRI certificates published by NEEP: maximum capacity at 5 °F ÷ rated capacity at 47 °F. ENERGY STAR does its own verification; the directory does not publish the details of its decision for each pair.
Below −15 °C: every published value, none invented
The DA25’s certificate stops at −15 °C: NEEP publishes no colder point for it, and DIRECT AIR rates a heating range down to −25 °C with no capacity figure. The HEAT XTREME PRO R-454B’s certificate publishes a point at −30 °C. Between two published values, the table shows the range between them.
What DIRECT AIR publishes for each
DIRECT AIR publishes a brochure for the DA25 (March 2023). The HEAT XTREME PRO brochure we found (July 2022) describes the earlier R-410A version, with DIRM- model numbers; no DIRECT AIR document was found for the R-454B version (DIRM4-) sold here. So we attribute no feature to it: the column says so, line by line.
DA25−25 to 24 °C.
HEAT XTREME PRONot published by DIRECT AIR for the R-454B version; coldest certified point: −30 °C.
DA25 brochure, specifications table; AHRI certificate 216571373
DA25Turbo, Eco, sleep; 12 fan speeds.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25“Follow Me” documented.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25Motion sensor on the wall unit.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25Optional, compatible with Google and Alexa.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25Automatic restart and louver position memory.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25Biofilter and self-cleaning cycle.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25Refrigerant leak detector.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
DA25Anti-corrosion fins.
HEAT XTREME PRONot published for the R-454B version.
DA25 brochure
Indoor unit sound is published for neither
What is published. The DA25 brochure gives a single sound level, for the outdoor unit: 53.5 dB(A). It gives no level for the wall unit, speed by speed.
What is not. No DIRECT AIR document was found for the HEAT XTREME PRO R-454B, so no sound level is published for it. We do not compare what we cannot source.
Indoor sound: published for neither one. Outdoor sound: 53.5 dB(A) for the DA25 per DIRECT AIR, method not stated; not published for the HEAT XTREME PRO R-454B.
What to know for the installation
The DA25’s values come from its brochure. For the HEAT XTREME PRO R-454B, DIRECT AIR publishes no installation sheet that we could find; the column says so. For a specific figure, we can check with the distributor.
| Installation, per DIRECT AIR | DIRECT AIR DA25 R-410A | DIRECT AIR HEAT XTREME PRO R-454B |
|---|---|---|
| Refrigerant and charge | R-410A, 38.1 oz | R-454Bcharge not published |
| Outdoor unit W × H × D | 30.12 × 21.85 × 11.93 in | Not published by the manufacturer |
| Indoor unit, weight | 22.93 lb | Not published by the manufacturer |
| Outdoor unit, weight | 63.71 lb | Not published by the manufacturer |
| Liquid – gas diameters | 1/4 – 1/2 in | Not published by the manufacturer |
| Maximum piping length | 82 ftminimum length and precharged length not published | Not published by the manufacturer |
| Maximum height difference | 32.8 ft | Not published by the manufacturer |
| Electrical protection | 208/230 V; maximum breaker 15 A | 208/230 VAHRI certificate; protection not published |
| Rated heating / cooling range | −25 to 24 °C / −25 to 50 °C | Not published by the manufacturer |
Source: DIRECT AIR (Powrmatic), DA25 brochure, French and English versions, “Printed in Canada 2023-03”, consulted November 9, 2026. The brochure pairs the DIRM-12DA25-WM indoor unit; the AHRI certificate and NEEP list DIRM-12HP-WM.
What we get asked about these two DIRECT AIR units
Can an R-410A heat pump still be sold in Canada?
The federal Ozone-depleting Substances and Halocarbon Alternatives Regulations (SOR/2016-137), in the version current to October 19, 2026, set no GWP limit for residential split heat pumps: their Schedule 1.1 covers other equipment. The total quantity of HFCs imported into Canada, on the other hand, has been decreasing in steps since 2019. Provincial and municipal rules may add their own requirements.
What does “A2L” mean for R-454B?
This is the safety class from the ASHRAE 34 standard: “A” for low toxicity, “2L” for low flammability. R-410A is classed A1 (non-flammable under test conditions). R-454B units are designed and installed according to the specific requirements for A2L refrigerants.
Why doesn’t the DA25 have the cold-climate label?
The directory does not publish the reason. The certificates allow a calculation: at −15 °C, the DA25 delivers at most 8,000 BTU/h, i.e. 67% of its 12,000 BTU/h rated at 8.3 °C; ENERGY STAR’s cold-climate criterion requires at least 70%. The HEAT XTREME PRO R-454B delivers 11,500, i.e. 96%.
What does the DA25 deliver below −15 °C?
NEEP publishes no colder point for it. DIRECT AIR rates a heating range down to −25 °C, with no capacity figure at those temperatures. For the HEAT XTREME PRO R-454B, the certificate publishes 5,900 BTU/h maximum at −30 °C.
Is the HEAT XTREME PRO R-454B sold under other names?
Three 12,000 BTU pairs have exactly the same AHRI and NEEP certified values: SENVILLE AURA R454B (AHRI 215735296), MIDEA MIDEA28 (215471381) and BOSCH Climate 5000 MAX PERFORMANCE R-454B (215223282), checked November 9, 2026.
Which one is quieter?
The documents do not allow us to say: no indoor sound level is published for either one.
What about the warranty?
This page does not compare warranties. The manufacturer’s warranty documents are provided with the quote.
The AHRI certificate values, as published
| Certified value (AHRI, via NEEP) | DIRECT AIR DA25 R-410A | DIRECT AIR HEAT XTREME PRO R-454B |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 24.6 | 25.4 |
| EER2 | 13.7 | 13.4 |
| HSPF2 Region IV | 10.7 | 10.5 |
| HSPF2 Region V | 8.1 | 8.0 |
| Rated capacity at 35 °C | 12,000 BTU/h | 12,000 BTU/h |
| Heating at 8.3 °C (47 °F) | ||
| Capacity min. / rated / max. | 3,962 / 12,000 / 13,941 BTU/h | 3,800 / 12,000 / 16,000 BTU/h |
| Maximum capacity | 13,941 BTU/h | 16,000 BTU/h |
| COP min. / rated / max. | 4.00 / 3.70 / 3.55 | 4.84 / 3.74 / 3.35 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity min. / rated / max. | 2,959 / 9,000 / 9,921 BTU/h | 5,300 / 12,000 / 12,800 BTU/h |
| Maximum capacity | 9,921 BTU/h | 12,800 BTU/h |
| COP min. / rated / max. | 2.41 / 2.69 / 2.31 | 2.22 / 2.51 / 1.75 |
| Heating at −15 °C (5 °F) | ||
| Capacity min. / rated / max. | 2,305 / 8,000 / 8,000 BTU/h | 4,100 / 11,500 / 11,500 BTU/h |
| Maximum capacity | 8,000 BTU/h | 11,500 BTU/h |
| COP min. / rated / max. | 1.73 / 2.39 / 2.39 | 1.72 / 1.80 / 1.80 |
| Coldest published point | ||
| Test temperature | −15 °C (5 °F)no colder point published | −30 °C (−22 °F) |
| Capacity min. and max. | 2,305 and 8,000 BTU/h | 2,000 and 5,900 BTU/h |
| Certificates | ||
| Certificate: indoor and outdoor units | DIRM-12HP-WM and DIRM-12DA25-1Z | DIRM4-12HP-WM and DIRM4-12HXPRO28-1Z |
| Refrigerant | R-410AGWP 2,088 (IPCC, AR4); class A1 (ASHRAE 34) | R-454BGWP 466 (IPCC, AR4); class A2L (ASHRAE 34) |
| ENERGY STAR and cold climate | Yes; cold climate: noper NEEP, Nov. 9, 2026 | Yes; cold climate: yesper NEEP, Nov. 9, 2026 |
| AHRI certificate · NEEP record | 207743720 · record 405054 | 216571373 · record 382480 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. The coldest published points are not at the same temperature: they cannot be compared with each other.
Both DIRECT AIR units are on the AirGreen website.
A question about either one, or about the installation in your home? Talk to our team.
Documents consulted
Data checked November 9, 2026. Performance: AHRI certificates and NEEP database. Features, dimensions, sound and piping: per the manufacturer. Regulations: official texts cited, summarized by AirGreen; this summary is not legal advice. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. DIRECT AIR, DA25 and HEAT XTREME PRO are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for the brand; this page is not produced, sponsored or endorsed by the manufacturer.
Photos: AirGreen and manufacturer, for identification.
Does a figure look wrong to you? Write to us : any reported value is checked again.