SHARP BU triple-zone heat pump installation in Saint-Eustache, compared with the FUJITSU AIRSTAGE AQUILA R32

Three SHARP heads in Saint-Eustache: 12,000 BTU in the large room and 9,000 in the other two, on a 24,000 BTU outdoor unit. The job, then the comparison with the FUJITSU AIRSTAGE AQUILA R32 when the house sits empty in midwinter.

By AirGreen Climatisation & Chauffage Admin13 min read
SHARP BU triple-zone heat pump installation in Saint-Eustache, compared with the FUJITSU AIRSTAGE AQUILA R32
SHARP BU triple-zone heat pump installation in Saint-Eustache, compared with the FUJITSU AIRSTAGE AQUILA R32
–chapters in this story
13 minreading time
–type of installation
2024year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job
Comparison · Multi-zone project · 3 heads

SHARP BU in Saint-Eustache, compared with the FUJITSU AIRSTAGE AQUILA R32

A house in Saint-Eustache, three wall heads: 12,000 BTU in the large room and 9,000 in each of the other two, on a single 24,000 BTU SHARP outdoor unit. Here is the job, then a question owners ask sooner or later: what does each system do when the house sits empty in the middle of winter?

HSPF2 Region V
9.0·8.5
SHARP BU · FUJITSU AIRSTAGE AQUILA R32, AHRI certificates
Certified min. capacity at −15 °C
8,400·3,900
BTU/h, NEEP
Advertised heating range
−27 °C·−15 °C
low limit, manufacturers’ documents
10 °C hold mode
not found·yes
SHARP 2025 brochure · FG2057B p. 23
SHARP
AirGreen product card for the SHARP BU triple-zone heat pump: three wall heads and the outdoor unit

BU · 24,000 BTU, three heads

Outdoor AE-X3M24BU · heads AY-XPC9BU ×2 + AY-XPC12BU
AHRI 213927543 · NEEP 507394 · R-32

See the product page
FUJITSU AIRSTAGE
AirGreen product card for the FUJITSU AIRSTAGE AQUILA three-zone heat pump: three wall heads and the outdoor unit

AQUILA R32 · 24,000 BTU, three zones

Outdoor AOUH24KWAS3 · heads ASUH09KPAS / ASUH12KPAS
AHRI 215447687 · NEEP 455170 · R-32

See the product page
Estimated running cost

A Saint-Eustache house lived in all winter: the electricity in dollars

AirGreen estimate for the same 24,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both carry the number 24,000; the FUJITSU AIRSTAGE AQUILA R32 is certified at 22,000 BTU/h in cooling at 35 °C, the SHARP BU at 24,000. The calculation keeps 24,000 for both so the same house serves as the base. Only their certified efficiencies change. Electric baseboards serve as a reference point.

How this amount is calculated
  1. The heat to supply. A zone whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature, with 4,167 degree-days below 18 °C (NRCan, HOT2000 climate map, Montréal Intl): about kWh of heat for a full winter, heating 24 hours a day. The heating slider reduces this total in proportion to the hours.
  2. Each heat pump’s electricity. Heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (NEEP). Electric baseboards use 1 kWh per kWh of heat.
  3. Cooling. 24,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000.
  4. The price. Hydro-Québec Rate D in force April 1, 2026: 7.065¢ per kWh up to 40 kWh per day, 11.142¢ above, 9.104¢ on average; × 1.14975 for GST and QST. The access charge, the same in every case, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The job · Saint-Eustache

One large room, two small ones

White SHARP wall head mounted high on a taupe wall, near a window with a dark curtain
One of the house’s three SHARP heads, near a window. Photo: AirGreen.

The owners wanted to heat and cool three zones of the house separately. AirGreen installed a 12,000 BTU head in the largest room and a 9,000 BTU head in each of the other two, all connected to a 24,000 BTU SHARP AE-X3M24BU outdoor unit.

Each head sits high on the wall, out of the way, so the air does not blow straight at people sitting down.

SHARP provides for this 12 + 9 + 9 split on the AE-X3M24BU: it is among the three-head combinations in its 2025 brochure (p. 13).

12Large room12,000 BTU
9Room 29,000 BTU
9Room 39,000 BTU
What remains from the original articleSaint-Eustache, the three zones and the size of their heads, the job photo, the care taken not to blow on the occupants.
What was removedA rank taken from an old AirGreen guide, the grant amount, health effects attributed to ionization and self-cleaning, environmental claims, the 10-year warranty and the "50.0 dB(A)" presented as silent: none of it was backed by a verifiable document.
Empty house in January

Leaving for two weeks in the dead of winter

A house left empty in January does not need 21 °C, but it must not freeze. Three documents answer the question: the heating range each manufacturer advertises, the 10 °C hold mode it describes or not, and the smallest certified capacity of its outdoor unit.

Outdoor temperature
House setting
SHARP BU AE-X3M24BU
FUJITSU AIRSTAGE AQUILA R32 AOUH24KWAS3

Schematics. Capacities: NEEP listings 507394 and 455170 (−8.3 °C and −15 °C certified; SHARP also −27.2 °C). Advertised ranges: SHARP 2025 brochure (−27 to 24 °C) and FUJITSU AIRSTAGE FG2057B, p. 17 (−15 to 24 °C). 10 °C mode: FG2057B, p. 23. No value is calculated between two points; the page does not estimate how much heat an empty house loses.

Extreme cold

Below −15 °C: what SHARP still publishes, where the FUJITSU AIRSTAGE range ends

Maximum heating capacity of the outdoor unit. Both are certified at the same −15 °C point. Lower down, SHARP certifies −27.2 °C and publishes values at −20 and −25 °C; FUJITSU AIRSTAGE ends the AOUH24KWAS3 heating range at −15 °C in its brochure and publishes no capacity below that.

Features

Minimum Heat, Wi-Fi, pan heater: what is in black and white

Only features written in the SHARP 2025 brochure, the FUJITSU AIRSTAGE FG2057B brochure (rev. 8/2025) or each system’s NEEP listing are included. What a document does not mention is stated as such.

10 °C hold mode

FUJITSU AIRSTAGE "Minimum Heat": sets the room to 10 °C to keep it above freezing (FG2057B, p. 23).

SHARP Not found in the 2025 brochure.

Wi-Fi control

FUJITSU AIRSTAGE AIRSTAGE app, with a USB adapter on the head (FG2057B, p. 6).

SHARP Not found in the 2025 brochure.

Outdoor unit base pan heater

FUJITSU AIRSTAGE NEEP listing: 150 W, based on temperature and mode. The brochure describes it only for the XLTH series.

SHARP No base pan heater listed on the NEEP listing.

Plasmacluster ionization

SHARP The brochure names the Plasmacluster technology. No effect is repeated here.

FUJITSU AIRSTAGE Not found in the brochure.

Number of heads

SHARP AE-X3M24BU: up to three heads, combinations listed on p. 13 of the 2025 brochure.

FUJITSU AIRSTAGE AOUH24KWAS3: up to three heads, combinations listed on p. 20 of FG2057B.

Advertised heating range

SHARP −27 to 24 °C.

FUJITSU AIRSTAGE −15 to 24 °C (AOUH24KWAS3, FG2057B p. 17).

Sound

SHARP BU or AQUILA R32 against the wall: the printed decibels

dB

How to read these numbers. Neither brochure states the measuring method or distance for these values, so they do not compare from one unit to the other. For the heads, SHARP publishes 23 to 43 dB(A) for the 9BU and 12BU heads, and FUJITSU AIRSTAGE 21 to 42 dB(A) depending on the head (ASUH09KPAS and ASUH12KPAS).

Why this is not a ranking. Two numbers from two brochures, with no common method, do not tell you which one you will hear less in the yard.

Measurements taken by each manufacturer with its own method, not stated: different method — not comparable.

Installation

An AQUILA R32 that weighs 14 lb less: both outdoor units at scale

Front view, dimensions published by each manufacturer. The AQUILA R32 is slightly narrower and shallower, barely 1/4 in taller, and 14 lb lighter; FUJITSU AIRSTAGE also publishes per-head lengths and the precharge.

InstallationSHARP BUFUJITSU AIRSTAGE AQUILA R32
Maximum line length230 ft (70 m) totalSHARP 2025 brochure164 ft (50 m) total; 82 ft (25 m) per headFG2057B, p. 17
Maximum height difference33 ft (10 m)SHARP 2025 brochure49 ft (15 m) outdoor – indoor; 33 ft (10 m) between heads
Precharged lengthNot found in the 2025 brochure98 ft (30 m) total
Liquid – gas diameters1/4 – 3/8 inper head1/4 – 3/8 inheads; outdoor: liquid 3 × 1/4 in, gas 2 × 3/8 + 1 × 1/2 in
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 115 lb32 5/16 × 28 3/16 × 12 3/8 in, 101 lb
Indoor unit, weight34 39/64 × 11 3/8 × 9 1/64 in (9BU and 12BU)weight not found in the brochure32 13/16 × 10 5/8 × 8 3/4 in, 21 lb (09 and 12)
Electrical protectionMax. fuse 25 AMax. fuse or breaker 20 AMCA 18 A; 208-230 V, single phase
Advertised heating / cooling range−27 to 24 °C / −10 to 46 °C−15 to 24 °C / −10 to 50 °C

Outdoor unit dimensions follow each manufacturer’s printed order, brought back to width × height × depth. Electrical and refrigerant connections belong to contractors holding the required licences.

Questions

An empty house in a Saint-Eustache winter: the questions

Is this pair already on another page?

The 24,000 BTU SHARP BU and FUJITSU AIRSTAGE AQUILA R32 are also compared in a two-zone version in Mercier–Hochelaga-Maisonneuve, from the angle of the air moved in each room. Here, the question is an empty house in winter, with three heads.

Do both manufacturers allow the 12 + 9 + 9 split?

SHARP lists it for the AE-X3M24BU (2025 brochure, p. 13). FUJITSU AIRSTAGE limits the AOUH24KWAS3 to three heads and refers to the combination table on p. 20 of FG2057B.

What does an advertised heating range down to −15 °C mean?

It is the low limit FUJITSU AIRSTAGE prints for the AOUH24KWAS3. The brochure publishes no heating capacity below it for this model. For houses where winter goes colder, plan with the contractor what heats below that limit.

Why does the smallest certified capacity matter?

A house set to 10 °C needs much less heat than at 21 °C. NEEP certifies a minimum capacity of 3,900 BTU/h at −15 °C for the FUJITSU AIRSTAGE and 8,400 BTU/h for the SHARP BU. Below that minimum, a heat pump stops and restarts rather than slowing down.

R-32 on both sides: what difference?

None as far as the refrigerant goes: both use R-32, classed A2L (mildly flammable) under ASHRAE Standard 34, with a global warming potential of 675 over 100 years (IPCC, Fourth Assessment Report).

Do assistance programs cover these two systems?

NEEP listings 507394 and 455170 both carry the ENERGY STAR and cold-climate designations. Each program’s official rules and lists decide eligibility and amounts, and they change: check the list of the program concerned (for example Hydro-Québec’s LogisVert) before buying.

Certified data

SHARP BU 24,000 and AQUILA R32 24,000, certificate against certificate

MeasureSHARP BU 24,000FUJITSU AIRSTAGE AQUILA R32 24,000
Season
SEER22423
EER21413
HSPF2 Region IV11.510.5
HSPF2 Region V98.5
Rated capacity at 35 °C24,000 BTU/h22,000 BTU/h
Heating, min. / rated / max.
Capacity min. / rated / max. at 8.3 °C8,800 / 26,000 / 30,000 BTU/h6,800 / 24,000 / 31,000 BTU/h
COP min. / rated / max. at 8.3 °C4.69 / 4.35 / 4.195.69 / 4.6 / 4.17
Capacity min. / rated / max. at −8.3 °C7,600 / 25,000 / 25,000 BTU/h4,700 / 15,600 / 22,600 BTU/h
COP min. / rated / max. at −8.3 °C2.93 / 2.53 / 2.534.05 / 3.34 / 2.56
Capacity min. / rated / max. at −15 °C8,400 / 21,200 / 21,200 BTU/h3,900 / 19,200 / 19,200 BTU/h
COP min. / rated / max. at −15 °C2.46 / 2.3 / 2.33.36 / 2.04 / 2.04
Coldest certified point
Test temperature−27.2 °C (−17 °F)−15 °C (5 °F)no colder point at NEEP
Capacity min. / max.5,100 / 14,600 BTU/h3,900 / 19,200 BTU/h
COP min. / max.1.74 / 1.843.36 / 2.04
Listings
ENERGY STAR · cold climateYes, bothYes, both
RefrigerantR-32 · A2L · GWP 675R-32 · A2L · GWP 675
AHRI certificate · NEEP listing213927543 · 507394non-ducted215447687 · 455170non-ducted

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities at different temperatures and the coldest point are not marked. The cooling COPs on NEEP listing 455170 are not consistent with one another; they are not included.

The SHARP BU and the AQUILA R32 are both available from AirGreen.

A house lived in all year or left empty in winter: let’s talk about yours.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP, listing 507394 (AHRI 213927543)SHARP AE-X3M24BU, non-ducted · accessed November 17, 2026
NEEP, listing 455170 (AHRI 215447687)FUJITSU AIRSTAGE AOUH24KWAS3, non-ducted · accessed November 17, 2026
SHARP, 2025 brochure (French)BU series: combinations p. 13, heads, range, dimensions, sound · accessed November 17, 2026
FUJITSU AIRSTAGE, "Série H Multizones" (H Series multi-zone), FG2057BRev. 8/2025; pp. 6, 7, 17, 20 and 23 · accessed November 17, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · accessed November 17, 2026
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days, −23.1 °C · accessed November 17, 2026
IPCC Fourth Assessment Report · ASHRAE 34100-year GWP and refrigerant safety class
The unit

The unit on this job, in figures

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp BU 24 0002 Zones (Dual Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Sharp BU 24 0003 Zones (Triple Zone)25,00021,200−27 °C: 14,6002.324.011.5$3,000
Most EfficientENERGY STAR

Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.

8,800BTU/h at low speed

Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.

−27 °CColdest certified point

NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.

675R-32 GWP

Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment