BU · 24,000 BTU, three heads
Outdoor AE-X3M24BU · heads AY-XPC9BU ×2 + AY-XPC12BU
AHRI 213927543 · NEEP 507394 · R-32
Three SHARP heads in Saint-Eustache: 12,000 BTU in the large room and 9,000 in the other two, on a 24,000 BTU outdoor unit. The job, then the comparison with the FUJITSU AIRSTAGE AQUILA R32 when the house sits empty in midwinter.

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A house in Saint-Eustache, three wall heads: 12,000 BTU in the large room and 9,000 in each of the other two, on a single 24,000 BTU SHARP outdoor unit. Here is the job, then a question owners ask sooner or later: what does each system do when the house sits empty in the middle of winter?

Outdoor AE-X3M24BU · heads AY-XPC9BU ×2 + AY-XPC12BU
AHRI 213927543 · NEEP 507394 · R-32

Outdoor AOUH24KWAS3 · heads ASUH09KPAS / ASUH12KPAS
AHRI 215447687 · NEEP 455170 · R-32
AirGreen estimate for the same 24,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both carry the number 24,000; the FUJITSU AIRSTAGE AQUILA R32 is certified at 22,000 BTU/h in cooling at 35 °C, the SHARP BU at 24,000. The calculation keeps 24,000 for both so the same house serves as the base. Only their certified efficiencies change. Electric baseboards serve as a reference point.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The owners wanted to heat and cool three zones of the house separately. AirGreen installed a 12,000 BTU head in the largest room and a 9,000 BTU head in each of the other two, all connected to a 24,000 BTU SHARP AE-X3M24BU outdoor unit.
Each head sits high on the wall, out of the way, so the air does not blow straight at people sitting down.
SHARP provides for this 12 + 9 + 9 split on the AE-X3M24BU: it is among the three-head combinations in its 2025 brochure (p. 13).
A house left empty in January does not need 21 °C, but it must not freeze. Three documents answer the question: the heating range each manufacturer advertises, the 10 °C hold mode it describes or not, and the smallest certified capacity of its outdoor unit.
Schematics. Capacities: NEEP listings 507394 and 455170 (−8.3 °C and −15 °C certified; SHARP also −27.2 °C). Advertised ranges: SHARP 2025 brochure (−27 to 24 °C) and FUJITSU AIRSTAGE FG2057B, p. 17 (−15 to 24 °C). 10 °C mode: FG2057B, p. 23. No value is calculated between two points; the page does not estimate how much heat an empty house loses.
Maximum heating capacity of the outdoor unit. Both are certified at the same −15 °C point. Lower down, SHARP certifies −27.2 °C and publishes values at −20 and −25 °C; FUJITSU AIRSTAGE ends the AOUH24KWAS3 heating range at −15 °C in its brochure and publishes no capacity below that.
Only features written in the SHARP 2025 brochure, the FUJITSU AIRSTAGE FG2057B brochure (rev. 8/2025) or each system’s NEEP listing are included. What a document does not mention is stated as such.
FUJITSU AIRSTAGE "Minimum Heat": sets the room to 10 °C to keep it above freezing (FG2057B, p. 23).
SHARP Not found in the 2025 brochure.
FUJITSU AIRSTAGE AIRSTAGE app, with a USB adapter on the head (FG2057B, p. 6).
SHARP Not found in the 2025 brochure.
FUJITSU AIRSTAGE NEEP listing: 150 W, based on temperature and mode. The brochure describes it only for the XLTH series.
SHARP No base pan heater listed on the NEEP listing.
SHARP The brochure names the Plasmacluster technology. No effect is repeated here.
FUJITSU AIRSTAGE Not found in the brochure.
SHARP AE-X3M24BU: up to three heads, combinations listed on p. 13 of the 2025 brochure.
FUJITSU AIRSTAGE AOUH24KWAS3: up to three heads, combinations listed on p. 20 of FG2057B.
SHARP −27 to 24 °C.
FUJITSU AIRSTAGE −15 to 24 °C (AOUH24KWAS3, FG2057B p. 17).
How to read these numbers. Neither brochure states the measuring method or distance for these values, so they do not compare from one unit to the other. For the heads, SHARP publishes 23 to 43 dB(A) for the 9BU and 12BU heads, and FUJITSU AIRSTAGE 21 to 42 dB(A) depending on the head (ASUH09KPAS and ASUH12KPAS).
Why this is not a ranking. Two numbers from two brochures, with no common method, do not tell you which one you will hear less in the yard.
Measurements taken by each manufacturer with its own method, not stated: different method — not comparable.
Front view, dimensions published by each manufacturer. The AQUILA R32 is slightly narrower and shallower, barely 1/4 in taller, and 14 lb lighter; FUJITSU AIRSTAGE also publishes per-head lengths and the precharge.
| Installation | SHARP BU | FUJITSU AIRSTAGE AQUILA R32 |
|---|---|---|
| Maximum line length | 230 ft (70 m) totalSHARP 2025 brochure | 164 ft (50 m) total; 82 ft (25 m) per headFG2057B, p. 17 |
| Maximum height difference | 33 ft (10 m)SHARP 2025 brochure | 49 ft (15 m) outdoor – indoor; 33 ft (10 m) between heads |
| Precharged length | Not found in the 2025 brochure | 98 ft (30 m) total |
| Liquid – gas diameters | 1/4 – 3/8 inper head | 1/4 – 3/8 inheads; outdoor: liquid 3 × 1/4 in, gas 2 × 3/8 + 1 × 1/2 in |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 115 lb | 32 5/16 × 28 3/16 × 12 3/8 in, 101 lb |
| Indoor unit, weight | 34 39/64 × 11 3/8 × 9 1/64 in (9BU and 12BU)weight not found in the brochure | 32 13/16 × 10 5/8 × 8 3/4 in, 21 lb (09 and 12) |
| Electrical protection | Max. fuse 25 A | Max. fuse or breaker 20 AMCA 18 A; 208-230 V, single phase |
| Advertised heating / cooling range | −27 to 24 °C / −10 to 46 °C | −15 to 24 °C / −10 to 50 °C |
Outdoor unit dimensions follow each manufacturer’s printed order, brought back to width × height × depth. Electrical and refrigerant connections belong to contractors holding the required licences.
The 24,000 BTU SHARP BU and FUJITSU AIRSTAGE AQUILA R32 are also compared in a two-zone version in Mercier–Hochelaga-Maisonneuve, from the angle of the air moved in each room. Here, the question is an empty house in winter, with three heads.
SHARP lists it for the AE-X3M24BU (2025 brochure, p. 13). FUJITSU AIRSTAGE limits the AOUH24KWAS3 to three heads and refers to the combination table on p. 20 of FG2057B.
It is the low limit FUJITSU AIRSTAGE prints for the AOUH24KWAS3. The brochure publishes no heating capacity below it for this model. For houses where winter goes colder, plan with the contractor what heats below that limit.
A house set to 10 °C needs much less heat than at 21 °C. NEEP certifies a minimum capacity of 3,900 BTU/h at −15 °C for the FUJITSU AIRSTAGE and 8,400 BTU/h for the SHARP BU. Below that minimum, a heat pump stops and restarts rather than slowing down.
None as far as the refrigerant goes: both use R-32, classed A2L (mildly flammable) under ASHRAE Standard 34, with a global warming potential of 675 over 100 years (IPCC, Fourth Assessment Report).
NEEP listings 507394 and 455170 both carry the ENERGY STAR and cold-climate designations. Each program’s official rules and lists decide eligibility and amounts, and they change: check the list of the program concerned (for example Hydro-Québec’s LogisVert) before buying.
| Measure | SHARP BU 24,000 | FUJITSU AIRSTAGE AQUILA R32 24,000 |
|---|---|---|
| Season | ||
| SEER2 | 24 | 23 |
| EER2 | 14 | 13 |
| HSPF2 Region IV | 11.5 | 10.5 |
| HSPF2 Region V | 9 | 8.5 |
| Rated capacity at 35 °C | 24,000 BTU/h | 22,000 BTU/h |
| Heating, min. / rated / max. | ||
| Capacity min. / rated / max. at 8.3 °C | 8,800 / 26,000 / 30,000 BTU/h | 6,800 / 24,000 / 31,000 BTU/h |
| COP min. / rated / max. at 8.3 °C | 4.69 / 4.35 / 4.19 | 5.69 / 4.6 / 4.17 |
| Capacity min. / rated / max. at −8.3 °C | 7,600 / 25,000 / 25,000 BTU/h | 4,700 / 15,600 / 22,600 BTU/h |
| COP min. / rated / max. at −8.3 °C | 2.93 / 2.53 / 2.53 | 4.05 / 3.34 / 2.56 |
| Capacity min. / rated / max. at −15 °C | 8,400 / 21,200 / 21,200 BTU/h | 3,900 / 19,200 / 19,200 BTU/h |
| COP min. / rated / max. at −15 °C | 2.46 / 2.3 / 2.3 | 3.36 / 2.04 / 2.04 |
| Coldest certified point | ||
| Test temperature | −27.2 °C (−17 °F) | −15 °C (5 °F)no colder point at NEEP |
| Capacity min. / max. | 5,100 / 14,600 BTU/h | 3,900 / 19,200 BTU/h |
| COP min. / max. | 1.74 / 1.84 | 3.36 / 2.04 |
| Listings | ||
| ENERGY STAR · cold climate | Yes, both | Yes, both |
| Refrigerant | R-32 · A2L · GWP 675 | R-32 · A2L · GWP 675 |
| AHRI certificate · NEEP listing | 213927543 · 507394non-ducted | 215447687 · 455170non-ducted |
higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities at different temperatures and the coldest point are not marked. The cooling COPs on NEEP listing 455170 are not consistent with one another; they are not included.
A house lived in all year or left empty in winter: let’s talk about yours.
Data verified November 17, 2026. Certified values: AHRI certificates, accessed in the NEEP database. Declared values: the manufacturers’ documents cited above.
SHARP, FUJITSU AIRSTAGE (also sold under the GENERAL AIRSTAGE name) and the other brands cited belong to their owners. Logos and images are used only to identify the products. AirGreen is a retailer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a value look wrong? Write to us.
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Flip each card to see what we do instead.
Three habits per season for this unit. They take a few minutes and prevent many calls.
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).