Project

Installing a SHARP ZU1 wall heat pump in Boucherville, compared with the GREE CLIVIA R32 (18,000 BTU)

A Boucherville home, an open-plan living area and an 18,000 BTU SHARP ZU1. The project, then the same-size GREE CLIVIA R32: estimated electricity cost, airflow, deep cold and installation, backed by certified values.

By AirGreen Climatisation & Chauffage Admin16 min read
Installing a SHARP ZU1 wall heat pump in Boucherville, compared with the GREE CLIVIA R32 (18,000 BTU)
Installing a SHARP ZU1 wall heat pump in Boucherville, compared with the GREE CLIVIA R32 (18,000 BTU)
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Comparison · Wall heat pump · 18,000 BTU

One open-plan space, one 18,000 BTU wall unit: the SHARP ZU1 we installed and the GREE CLIVIA R32, figure by figure

In Boucherville, a family wanted one wall unit to heat and cool its open-plan living area. AirGreen installed an 18,000 BTU SHARP ZU1. Here is that project, then the same-size GREE CLIVIA R32, which a buyer in the same situation would also look at: certificates, airflow and installation limits, side by side. Neither one is ranked.

HSPF2 region V 9 · 7.6SEER2 24 · 24.5Rated heating at 8.3 °C 21,600 · 18,000Coldest certified point 11,500 at −27.2 °C · 9,900 at −30 °C
AirGreen product card of the SHARP ZU1 18,000 BTU: indoor unit, outdoor unit and remote
SHARP

ZU1 · 18,000 BTU

Indoor AY-XP18ZU1 · outdoor AE-X18ZU1
AHRI certificate 213246053 · NEEP 507396

The model installed in Boucherville.

See the product page
AirGreen product card of the GREE CLIVIA R32 18,000 BTU: indoor unit, outdoor unit and remote
GREE

CLIVIA R32 · 18,000 BTU

Indoor GWH18AUDXF-D6DN***/I · outdoor GWH18AGDXF-D6DNA4B/O
AHRI certificate 216052270 · NEEP 383415

Also certified under AHRI 218426267, same AHRI and NEEP certified values.

See the product page

AirGreen product cards; the grant and certification badges are masked. Both units use R-32, an A2L class refrigerant. Values in BTU/h, AHRI certificates published by NEEP.

Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards are the reference point.

How this amount is calculated
  1. Heat to supply over the winter. A zone whose heat loss reaches 18,000 BTU/h (5.28 kW) at −23.1 °C, Montréal's design temperature: 5.28 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 12,838 kWh of heat for 24-hour heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day ("Heating" slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down when the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in force on April 1, 2026: 7.065¢ per kWh up to 40 kWh per day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The project

Boucherville: one open-plan space, one wall unit

The request fit in one sentence: one unit to heat the home's open-plan living area in winter and cool it during heat waves. AirGreen installed an 18,000 BTU SHARP ZU1 wall heat pump.

Outside, the unit sits on a ground stand, on pavers, under the roof overhang. SHARP's installation manual asks for at least 10 in of space above snow buildup, and advises against a drain hose in cold regions, because it can freeze.

An open-plan space raises a question the spec sheets only touch on sideways: how much air does the unit move, and how loud is it? That is this page's angle. The 18,000 BTU GREE CLIVIA R32 is the point of comparison: same type, same nominal size, same refrigerant, and its documents publish airflow and sound at every speed.

LocationBoucherville, South Shore
RoomThe open-plan living area of a family home
RequestHeat in winter and cool during heat waves, with a single unit
UnitSHARP ZU1 18,000 BTU · AY-XP18ZU1 / AE-X18ZU1 · AHRI certificate 213246053
Outdoor unitOn a ground stand, on pavers, along the wall and under the roof overhang
SHARP outdoor unit on a ground stand under the roof overhang, AirGreen job in Boucherville
AirGreen photo of the Boucherville job.
The open-plan space

How much air each one moves through the room

SHARP and GREE publish the indoor fan airflow at each speed, and the sound level at those speeds. Pick the mode, the speed and the size of your open-plan space: the diagram shows the published airflow, and the calculation shows how many times per hour the room's air volume passes through the unit.

Read this before drawing conclusions. More airflow moves more air; it says nothing about how far the jet reaches or comfort in a corner of the room, and it usually comes with more noise. SHARP lists five speeds and GREE seven: the page compares the highest, the middle and the lowest of each. SHARP publishes one airflow for heating and another for cooling; GREE publishes a single one. AirGreen calculation: airflow (cfm) × 60 ÷ (floor area × 8 ft). Diagram, not to scale.
Deep cold

Below −15 °C: what each manufacturer publishes

The certificates give capacity down to −15 °C, then a single colder point: −27.2 °C for the ZU1, −30 °C for the CLIVIA R32. In between, the SHARP brochure publishes maximum capacities at −20 and −25 °C. GREE publishes none in the documents consulted: the page shows the range between its two certified points.

Two different cold points. Do not compare 11,500 BTU/h at −27.2 °C and 9,900 BTU/h at −30 °C as if they were measured under the same conditions. At −15 °C, measured the same way by the certificate, maximum capacities are 18,000 BTU/h for the ZU1 and 14,600 BTU/h for the CLIVIA R32. The SHARP brochure prints model AY-XPC18ZU / AE-X18ZU; its values match the ZU1 certificate at the common points (−8.3, −15 and −27 °C).
Features

What each manufacturer writes, feature by feature

Only the features named in the SHARP ZU/ZHU brochure, the GREE CLIVIA R32 brochure and the GREE service manual are listed. When a document is silent, the page says so; silence does not prove the feature is missing.

Wi-Fi and app

SHARP ZU1 Built-in Wi-Fi on every unit in the series, per the brochure. The app name is not given.

GREE CLIVIA R32 Built-in Wi-Fi per the brochure; the service manual describes the GREE+ app.

Airflow direction (louvers)

SHARP ZU1 Coanda airflow with a long vane, and the Multi Space function, per SHARP.

GREE CLIVIA R32 Swing louver control.

Defrost

SHARP ZU1 RAPID DEFROST and DEFROST modes; HOT GAS PIPE system with multiple drain holes and PRE-WARM.

GREE CLIVIA R32 Not stated in the documents consulted.

Auto restart

SHARP ZU1 Automatic restart after a power outage.

GREE CLIVIA R32 Not stated in the documents consulted.

Cleaning and maintenance

SHARP ZU1 Plasmacluster cleaning function: the page gives the function's name, not the claimed effects.

GREE CLIVIA R32 Auto-clean and self-diagnosis.

Refrigerant leak detector

SHARP ZU1 Not stated in the brochure consulted.

GREE CLIVIA R32 A2L leak detection sensor included.

Presence sensor

SHARP ZU1 The brochure states the motion-sensor options are only available on the ZHU series; the ZU1 belongs to the ZU series.

GREE CLIVIA R32 Not stated in the documents consulted.

Sound

Sound, speed by speed

In an open-plan space, the unit spends much of its time at low speed. Here are the published heating levels for each indoor-unit speed, then the outdoor unit's level.

Indoor unit, heating

SHARP: five speeds (Sh, H, M, B, Sb), measurement method not stated in the brochure. GREE: seven speeds, sound pressure per the service manual, from highest (1) to lowest (7).

Outdoor unit

SHARP: 52 dB(A) in heating, method not stated. GREE: sound pressure of 59 dB(A); the manual also gives a sound power of 69 dB(A), a different measure.

dB

How to read these figures. dB(A) is a logarithmic scale: 3 dB more is about twice the sound energy. Each dot is a published speed; the lower the value, the quieter the unit at that speed.

Why this is not a ranking. SHARP does not say how its levels are measured; GREE publishes a sound pressure. Two different methods cannot be compared decibel for decibel: different method — not comparable.

Each manufacturer measures with its own method; the figures give an order of magnitude, not a ranking.

Installation

On the wall, outside and in between

Dimensions, piping lengths and electrical protection, as published by each manufacturer. The indoor units are shown to the scale of their width.

SHARP ZU141 27/64 in wide
SHARP ZU1 18,000 BTU indoor unit
41 27/64 in
GREE CLIVIA R3239 3/32 in wide
GREE CLIVIA R32 18,000 BTU indoor unit
39 3/32 in

Is your wall wide enough?

48 in

Cabinet width only. The clearances needed on each side are in each model's installation manual.

The line set between the two units

25 ft
Published dataSHARP ZU1GREE CLIVIA R32
Maximum piping length65.6 ft (20 m)ZU/ZHU/BU installation manual, EN-2; the brochure rounds to 66 ft131.2 ft (40 m)Service manual, p. 18; brochure
Pre-charged length25 ft (7.6 m)Beyond that: 0.16 oz/ft24.6 ft (7.5 m)Beyond that: 0.2 oz/ft
Maximum height difference32.8 ft (10 m)82 ft (25 m)
Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 95 lb37 46/64 × 25 63/64 × 15 53/64 in, 94.8 lb
Indoor unit W × H × D, weight41 27/64 × 12 7/16 × 9 51/64 in, 31 lb39 3/32 × 12 1/4 × 8 47/64 in, 28.7 lb
Power supply208-230 V, single phase, 60 Hz208/230 V, single phase, 60 Hz
Electrical protection20 A circuit breakerInstallation manual, EN-6; the brochure prints a 25 A max. fuse; MCA not printedMCA 16 A, MOCP 20 AGREE CLIVIA R32 brochure
Dehumidification5.1 pt/hUnit printed “Pt/h”3.80 pt/h (1.8 L/h)
Advertised heating / cooling range−27 to 24 °C / −10 to 46 °C−30 to 30 °C / −29 to 50 °C
Fan speeds5 speeds (Sh, H, M, B, Sb)7 speeds

Values from the manufacturers' documents. An installation is planned with the exact model's installation manual.

FAQ

Frequently asked questions

Why compare this project’s ZU1 with the GREE CLIVIA R32?

Because a buyer in the same situation, an open-plan space to heat and cool with one wall unit, looks at units of the same type and size. The 18,000 BTU CLIVIA R32 is sold by AirGreen, uses the same refrigerant, and its documents publish airflow and sound at every speed, which makes the “Open plan” section possible. This choice is not a ranking.

Does this page rank the units?

No. It shows the certified and published values side by side, with their source and test conditions. A value is marked “higher” only when the measure and conditions are the same for both.

Does an “18,000 BTU” ZU1 heat at 18,000 BTU/h?

AHRI certificate 213246053 gives a rated heating capacity of 21,600 BTU/h at 8.3 °C and a maximum capacity of 18,000 BTU/h at −15 °C. For the CLIVIA R32 (certificate 216052270), they are 18,000 and 14,600 BTU/h. The number in the name is the unit's size; the certificate gives the capacity at each test condition.

Does the SHARP ZU1 have a motion sensor?

According to the SHARP ZU/ZHU brochure, the motion-sensor options are only available on the ZHU series. The ZU1 installed in Boucherville belongs to the ZU series.

Does higher airflow mean more comfort?

Not necessarily. Airflow tells how much air passes through the unit each minute. How the air spreads depends on the room, where the unit sits and the louvers, and more airflow usually comes with more noise. Look at both together.

Are these units eligible for LogisVert?

Eligibility depends on Hydro-Québec's official list on the date of purchase, and that list changes. Check the list in force for the exact model. This page announces no amount.

Why does the GREE CLIVIA R32 have two certificate numbers?

NEEP lists two certificates for outdoor unit GWH18AGDXF-D6DNA4B/O with the CLIVIA indoor unit: 216052270, the one on AirGreen's product page, and 218426267, with indoor unit GWH18AUDXF-D6DNA2C printed in the brochure. Every certified value compared on November 17, 2026 is identical.

Certified data sheet

The certificate values, line by line

ValueSHARP ZU1GREE CLIVIA R32
Certificate
AHRI certificate · NEEP record213246053 · NEEP 507396216052270 · NEEP 383415Also 218426267 · NEEP 426064, same values
RefrigerantR-32 · GWP 675 (IPCC AR4) · class A2LR-32 · GWP 675 (IPCC AR4) · class A2L
ENERGY STARYes, cold climate included (NEEP)Yes, cold climate included (NEEP)
Seasonal efficiency
SEER22424.5
EER21313.65
HSPF2 region IV119
HSPF2 region V97.6
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.5,500 / 21,600 / 25,600 BTU/h4,400 / 18,000 / 19,310 BTU/h
COP min. / rated / max.5.76 / 4.22 / 3.685.37 / 3.91 / 3.33
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.7,500 / 22,000 / 22,000 BTU/h7,900 / 18,000 / 18,500 BTU/h
COP min. / rated / max.3.38 / 2.38 / 2.382.89 / 2.15 / 2.10
Heating at −15 °C (5 °F)
Capacity min. / rated / max.5,800 / 18,000 / 18,000 BTU/h6,700 / 14,600 / 14,600 BTU/h
COP min. / rated / max.2.93 / 2.20 / 2.202.81 / 1.90 / 1.90
Coldest certified point
Test temperature−27.2 °C (−17 °F)−30 °C (−22 °F)
Capacity min. / max.3,200 / 11,500 BTU/h5,000 / 9,900 BTU/h
COP min. / max.2.04 / 1.882.44 / 1.42
Cooling at 35 °C (95 °F)
Rated capacity at 35 °C: min. / rated / max.6,000 / 18,000 / 21,600 BTU/h4,400 / 18,000 / 22,178 BTU/h
COP min. / rated / max.5.67 / 3.82 / 2.935.16 / 4.00 / 3.33

“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation.

Both are on the AirGreen website.

The 18,000 BTU SHARP ZU1 and GREE CLIVIA R32 each have their product page on airgreen.ca, with their documents. For an open-plan space like the one in Boucherville, call us or request an estimate.

Sources

Documents consulted

NEEP — record 507396SHARP AY-XP18ZU1 / AE-X18ZU1, AHRI certificate 213246053; ashp.neep.org, modified Nov. 6, 2026, consulted Nov. 17, 2026
NEEP — records 383415 and 426064GREE CLIVIA, AHRI certificates 216052270 and 218426267; consulted Nov. 17, 2026
SHARP — “ZU/ZHU” brochureFrench, distributor RBL A/C, undated; columns AY-XPC18ZU / AE-X18ZU; consulted Nov. 17, 2026
SHARP — ZU/ZHU/BU installation manualglobal.sharp, IM_ZU_ZHU_BU.pdf, pages EN-2 and EN-6; consulted Nov. 17, 2026
GREE — CLIVIA R32 brochureUndated, file GREE_CLIVIA_R32.pdf; consulted Nov. 17, 2026
GREE — “Clivia Inverter Series R32” service manualGREE Electric Appliances, Inc. of Zhuhai, p. 17-18, copy hosted by manuals.plus, undated; consulted Nov. 17, 2026
Hydro-Québec — Electricity ratesApril 1, 2026, Rate D, sec. 2.5
NRCan — HOT2000 climate mapMontréal Intl station: 4,167 degree-days (base 18 °C), −23.1 °C
IPCC — Fourth Assessment Report (AR4); ASHRAE 34GWP of R-32 over 100 years: 675; safety class A2L

Going further

In figures
The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
The unit

What the unit delivers when it is cold

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment