ZU1 · 18,000 BTU
Indoor AY-XP18ZU1 · outdoor AE-X18ZU1
AHRI certificate 213246053 · NEEP 507396
The model installed in Boucherville.
See the product pageA Boucherville home, an open-plan living area and an 18,000 BTU SHARP ZU1. The project, then the same-size GREE CLIVIA R32: estimated electricity cost, airflow, deep cold and installation, backed by certified values.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
In Boucherville, a family wanted one wall unit to heat and cool its open-plan living area. AirGreen installed an 18,000 BTU SHARP ZU1. Here is that project, then the same-size GREE CLIVIA R32, which a buyer in the same situation would also look at: certificates, airflow and installation limits, side by side. Neither one is ranked.

Indoor AY-XP18ZU1 · outdoor AE-X18ZU1
AHRI certificate 213246053 · NEEP 507396
The model installed in Boucherville.
See the product page
Indoor GWH18AUDXF-D6DN***/I · outdoor GWH18AGDXF-D6DNA4B/O
AHRI certificate 216052270 · NEEP 383415
Also certified under AHRI 218426267, same AHRI and NEEP certified values.
See the product pageAirGreen product cards; the grant and certification badges are masked. Both units use R-32, an A2L class refrigerant. Values in BTU/h, AHRI certificates published by NEEP.
AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards are the reference point.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
The request fit in one sentence: one unit to heat the home's open-plan living area in winter and cool it during heat waves. AirGreen installed an 18,000 BTU SHARP ZU1 wall heat pump.
Outside, the unit sits on a ground stand, on pavers, under the roof overhang. SHARP's installation manual asks for at least 10 in of space above snow buildup, and advises against a drain hose in cold regions, because it can freeze.
An open-plan space raises a question the spec sheets only touch on sideways: how much air does the unit move, and how loud is it? That is this page's angle. The 18,000 BTU GREE CLIVIA R32 is the point of comparison: same type, same nominal size, same refrigerant, and its documents publish airflow and sound at every speed.

SHARP and GREE publish the indoor fan airflow at each speed, and the sound level at those speeds. Pick the mode, the speed and the size of your open-plan space: the diagram shows the published airflow, and the calculation shows how many times per hour the room's air volume passes through the unit.
The certificates give capacity down to −15 °C, then a single colder point: −27.2 °C for the ZU1, −30 °C for the CLIVIA R32. In between, the SHARP brochure publishes maximum capacities at −20 and −25 °C. GREE publishes none in the documents consulted: the page shows the range between its two certified points.
Only the features named in the SHARP ZU/ZHU brochure, the GREE CLIVIA R32 brochure and the GREE service manual are listed. When a document is silent, the page says so; silence does not prove the feature is missing.
SHARP ZU1 Built-in Wi-Fi on every unit in the series, per the brochure. The app name is not given.
GREE CLIVIA R32 Built-in Wi-Fi per the brochure; the service manual describes the GREE+ app.
SHARP ZU1 Coanda airflow with a long vane, and the Multi Space function, per SHARP.
GREE CLIVIA R32 Swing louver control.
SHARP ZU1 RAPID DEFROST and DEFROST modes; HOT GAS PIPE system with multiple drain holes and PRE-WARM.
GREE CLIVIA R32 Not stated in the documents consulted.
SHARP ZU1 Automatic restart after a power outage.
GREE CLIVIA R32 Not stated in the documents consulted.
SHARP ZU1 Plasmacluster cleaning function: the page gives the function's name, not the claimed effects.
GREE CLIVIA R32 Auto-clean and self-diagnosis.
SHARP ZU1 Not stated in the brochure consulted.
GREE CLIVIA R32 A2L leak detection sensor included.
SHARP ZU1 The brochure states the motion-sensor options are only available on the ZHU series; the ZU1 belongs to the ZU series.
GREE CLIVIA R32 Not stated in the documents consulted.
In an open-plan space, the unit spends much of its time at low speed. Here are the published heating levels for each indoor-unit speed, then the outdoor unit's level.
SHARP: five speeds (Sh, H, M, B, Sb), measurement method not stated in the brochure. GREE: seven speeds, sound pressure per the service manual, from highest (1) to lowest (7).
SHARP: 52 dB(A) in heating, method not stated. GREE: sound pressure of 59 dB(A); the manual also gives a sound power of 69 dB(A), a different measure.
How to read these figures. dB(A) is a logarithmic scale: 3 dB more is about twice the sound energy. Each dot is a published speed; the lower the value, the quieter the unit at that speed.
Why this is not a ranking. SHARP does not say how its levels are measured; GREE publishes a sound pressure. Two different methods cannot be compared decibel for decibel: different method — not comparable.
Each manufacturer measures with its own method; the figures give an order of magnitude, not a ranking.
Dimensions, piping lengths and electrical protection, as published by each manufacturer. The indoor units are shown to the scale of their width.


Cabinet width only. The clearances needed on each side are in each model's installation manual.
| Published data | SHARP ZU1 | GREE CLIVIA R32 |
|---|---|---|
| Maximum piping length | 65.6 ft (20 m)ZU/ZHU/BU installation manual, EN-2; the brochure rounds to 66 ft | 131.2 ft (40 m)Service manual, p. 18; brochure |
| Pre-charged length | 25 ft (7.6 m)Beyond that: 0.16 oz/ft | 24.6 ft (7.5 m)Beyond that: 0.2 oz/ft |
| Maximum height difference | 32.8 ft (10 m) | 82 ft (25 m) |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 1/2 in |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 95 lb | 37 46/64 × 25 63/64 × 15 53/64 in, 94.8 lb |
| Indoor unit W × H × D, weight | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb | 39 3/32 × 12 1/4 × 8 47/64 in, 28.7 lb |
| Power supply | 208-230 V, single phase, 60 Hz | 208/230 V, single phase, 60 Hz |
| Electrical protection | 20 A circuit breakerInstallation manual, EN-6; the brochure prints a 25 A max. fuse; MCA not printed | MCA 16 A, MOCP 20 AGREE CLIVIA R32 brochure |
| Dehumidification | 5.1 pt/hUnit printed “Pt/h” | 3.80 pt/h (1.8 L/h) |
| Advertised heating / cooling range | −27 to 24 °C / −10 to 46 °C | −30 to 30 °C / −29 to 50 °C |
| Fan speeds | 5 speeds (Sh, H, M, B, Sb) | 7 speeds |
Values from the manufacturers' documents. An installation is planned with the exact model's installation manual.
Because a buyer in the same situation, an open-plan space to heat and cool with one wall unit, looks at units of the same type and size. The 18,000 BTU CLIVIA R32 is sold by AirGreen, uses the same refrigerant, and its documents publish airflow and sound at every speed, which makes the “Open plan” section possible. This choice is not a ranking.
No. It shows the certified and published values side by side, with their source and test conditions. A value is marked “higher” only when the measure and conditions are the same for both.
AHRI certificate 213246053 gives a rated heating capacity of 21,600 BTU/h at 8.3 °C and a maximum capacity of 18,000 BTU/h at −15 °C. For the CLIVIA R32 (certificate 216052270), they are 18,000 and 14,600 BTU/h. The number in the name is the unit's size; the certificate gives the capacity at each test condition.
According to the SHARP ZU/ZHU brochure, the motion-sensor options are only available on the ZHU series. The ZU1 installed in Boucherville belongs to the ZU series.
Not necessarily. Airflow tells how much air passes through the unit each minute. How the air spreads depends on the room, where the unit sits and the louvers, and more airflow usually comes with more noise. Look at both together.
Eligibility depends on Hydro-Québec's official list on the date of purchase, and that list changes. Check the list in force for the exact model. This page announces no amount.
NEEP lists two certificates for outdoor unit GWH18AGDXF-D6DNA4B/O with the CLIVIA indoor unit: 216052270, the one on AirGreen's product page, and 218426267, with indoor unit GWH18AUDXF-D6DNA2C printed in the brochure. Every certified value compared on November 17, 2026 is identical.
| Value | SHARP ZU1 | GREE CLIVIA R32 |
|---|---|---|
| Certificate | ||
| AHRI certificate · NEEP record | 213246053 · NEEP 507396 | 216052270 · NEEP 383415Also 218426267 · NEEP 426064, same values |
| Refrigerant | R-32 · GWP 675 (IPCC AR4) · class A2L | R-32 · GWP 675 (IPCC AR4) · class A2L |
| ENERGY STAR | Yes, cold climate included (NEEP) | Yes, cold climate included (NEEP) |
| Seasonal efficiency | ||
| SEER2 | 24 | 24.5 |
| EER2 | 13 | 13.65 |
| HSPF2 region IV | 11 | 9 |
| HSPF2 region V | 9 | 7.6 |
| Heating at 8.3 °C (47 °F) | ||
| Capacity min. / rated / max. | 5,500 / 21,600 / 25,600 BTU/h | 4,400 / 18,000 / 19,310 BTU/h |
| COP min. / rated / max. | 5.76 / 4.22 / 3.68 | 5.37 / 3.91 / 3.33 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity min. / rated / max. | 7,500 / 22,000 / 22,000 BTU/h | 7,900 / 18,000 / 18,500 BTU/h |
| COP min. / rated / max. | 3.38 / 2.38 / 2.38 | 2.89 / 2.15 / 2.10 |
| Heating at −15 °C (5 °F) | ||
| Capacity min. / rated / max. | 5,800 / 18,000 / 18,000 BTU/h | 6,700 / 14,600 / 14,600 BTU/h |
| COP min. / rated / max. | 2.93 / 2.20 / 2.20 | 2.81 / 1.90 / 1.90 |
| Coldest certified point | ||
| Test temperature | −27.2 °C (−17 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 3,200 / 11,500 BTU/h | 5,000 / 9,900 BTU/h |
| COP min. / max. | 2.04 / 1.88 | 2.44 / 1.42 |
| Cooling at 35 °C (95 °F) | ||
| Rated capacity at 35 °C: min. / rated / max. | 6,000 / 18,000 / 21,600 BTU/h | 4,400 / 18,000 / 22,178 BTU/h |
| COP min. / rated / max. | 5.67 / 3.82 / 2.93 | 5.16 / 4.00 / 3.33 |
“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation.
The 18,000 BTU SHARP ZU1 and GREE CLIVIA R32 each have their product page on airgreen.ca, with their documents. For an open-plan space like the one in Boucherville, call us or request an estimate.
Data verified on November 17, 2026. Certified values come from the AHRI certificates published by NEEP; declared values come from the manufacturers' documents cited. The cost is an AirGreen estimate whose method is described above.
SHARP, GREE, CLIVIA and the other brands mentioned belong to their owners. Logos and images identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Three habits per season for this unit. They take a few minutes and prevent many calls.
Pick what looks like your need.
Flip each card to see what we do instead.
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).