Installation of a Sharp ZU1 18,000 BTU wall heat pump in Sainte-Thérèse, compared with the LG ARTCOOL PRESTIGE
In Sainte-Thérèse, an 18,000 BTU/h SHARP ZU1 was mounted under the ceiling of a freshly renovated room. How much of the wall each indoor unit takes, from the front and the side, the values published for deep cold and the certified values, next to the LG ARTCOOL PRESTIGE of the same size.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The article, chapter by chapter
A renovated room in Sainte-Thérèse: the SHARP ZU1 that was installed, next to the LG ARTCOOL PRESTIGE
The owner had just renovated his living space and wanted a unit that would suit the room, heat in winter and cool in summer. An 18,000 BTU/h SHARP ZU1 was mounted just under the ceiling. Here is what the certificates and the manufacturers publish for this unit and for the 18,000 BTU/h LG ARTCOOL PRESTIGE R32, a wall unit from LG's design line.


ARTCOOL PRESTIGE R32 · 18,000 BTU/h
Indoor KNSAL181A · outdoor KUSAL181A · AHRI 215828275 Same type, same size, R-32 See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day ("Heating" slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards: this is a simplification that does not account for recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in force on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
Sainte-Thérèse, a freshly renovated room and an indoor unit under the ceiling
In Sainte-Thérèse, the owner had just finished renovating his living space. He was looking for a heat pump that would go with the new decor, heating he could count on in winter and efficient cooling in summer.
An 18,000 BTU/h SHARP ZU1 was installed (indoor unit AY-XP18ZU1, outdoor unit AE-X18ZU1, R-32 refrigerant). The indoor unit was mounted just under the ceiling, in the corner of the room, next to the patio door. The team adjusted the system, then showed the owner the Wi-Fi control, the feature he liked most.
In a room that has just been redone, the first question is often visual: how much of the wall the indoor unit takes, from the front and from the side. The second comes with winter: what each unit still delivers in deep cold. This page answers both with the published values of the SHARP ZU1 and the LG ARTCOOL PRESTIGE.

What changed in this text. The earlier version presented this unit as the recommended pick of a buying guide, attributed an environmental benefit and a stated drop in consumption to the refrigerant, and announced grant amounts, an unsourced defrost percentage and effects on air quality and health. Those passages have been removed: a comparison page does not rank, makes no environmental or health claim, and assistance programs change (check Hydro-Québec's official list). The figures below come from the certificates and the manufacturers' documents.
How much room each indoor unit takes, from the front and from the side
The two indoor units are almost the same width. The difference shows elsewhere: in height and in how far they stand out from the wall. The drawings use the same scale, from the dimensions each manufacturer publishes.
The cut-out photos come from AirGreen's product cards and are set to the published width. The drawings compare the unit bodies only; the clearance required between the indoor unit and the ceiling is in each unit's installation manual. The colours and finishes offered are not described in the documents consulted.
After the renovation comes winter: what each unit publishes below −15 °C
NEEP certifies both units down to −15 °C, then gives one colder point: −27.2 °C for the SHARP ZU1, −25 °C for the LG. Each brochure adds maximum capacities: SHARP at −20 and −25 °C, LG at −18 °C. Cells with no published value show the range between the two points around them.
LG: the brochure prints its deep-cold capacities as a percentage of 21,600 BTU/h (113% at −8 °C, 100% at −15 °C, 90% at −18 °C, 68% at −25 °C) and a COP of 1.72 at −20 °C with no capacity. Its front page speaks of 100% at −25 °C; the table in the same document and the certificate give 14,780 BTU/h at −25 °C. This page follows the table and the certificate. SHARP: at the temperatures they share, the ZU/ZHU brochure values are identical to the ZU1 certificate.
What SHARP and LG describe, from the app to cleaning
The functions come from the SHARP brochure, the LG brochure and LG's submittal sheet for the same system. A function missing from a document is not necessarily missing from the unit; it is simply not described there.
SHARP: built-in Wi-Fi announced for the series.
LG: built-in Wi-Fi, control through the LG ThinQ app; remote "Smart Diagnosis".
SHARP: Coanda effect with a long louver that sends air along the ceiling.
LG: 4-way automatic swing.
SHARP: not described in the brochure consulted.
LG: Jet Cool and Jet Heat, sleep mode, 24-hour timer, auto changeover, auto restart.
SHARP: "Hot Gas Pipe" system for defrosting.
LG: heating element built into the condensate pan.
SHARP: Plasmacluster technology (name only, no effect attributed here).
LG: self-cleaning indoor coil.
SHARP: heating announced from −27 to 24 °C.
LG: heating announced down to −25 °C (LGRED technology); cold-climate certification stated.
In a freshly renovated room: each indoor unit's published noise
In a living space, the lowest speed is the one you hear most often. Each manufacturer publishes its own steps, in heating here for both.
Indoor unit, heating
How to read these numbers. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a fan speed published by the manufacturer, from slowest to fastest.
Why this is not a ranking. SHARP publishes five speeds in heating; LG publishes three in heating and adds a "very low" speed at 30 dB(A) in cooling only. Neither gives the distance or the measurement conditions. Outdoors, SHARP publishes 52 dB(A) and LG 56 dB(A) in heating, with the same caveat.
Measurements taken by each manufacturer with its own method: read them separately, not as a ranking.
Outside the room: each unit's outdoor unit and line set
The LG outdoor unit is taller and heavier, and its line set is 3/8 – 5/8 in. These measurements help choose the outdoor location and the line route.
| Installation, per the manufacturer | SHARP ZU1 18,000 | LG ARTCOOL PRESTIGE 18,000 |
|---|---|---|
| Maximum piping length | 66 ft (20 m)ZU/ZHU brochure | 164 ft (50 m)LG ARTCOOL Prestige brochure |
| Precharged lengthand charge to add beyond it | 25 ft; 0.16 oz/ft beyondZU/ZHU/BU installation manual | 24.6 ft; 0.32 oz/ft beyond |
| Maximum height difference | 33 ft (10 m) | 98.4 ft (30 m) |
| Liquid – gas diameters | 1/4 – 3/8 in | 3/8 – 5/8 in |
| Outdoor unit, dimensions and weight | 33 15/32 × 27 15/16 × 13 in (W × H × D), 95 lb | 37 13/32 in wide × 32 3/16 in high, 135.4 lb |
| Indoor unit, weightW × H × D | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb | 41 23/32 × 14 3/16 × 10 7/16 in, 37.7 lb |
| Indoor fan, airflow at the highest speed | Heating: 752 cfm | Heating: 919 cfm |
| Electrical protection | Max. fuse 25 A; 208-230 V | Min. circuit ampacity 19 A; max. protection 30 A; 208-230 V |
| Dehumidification | 2.4 L/h5.1 pints/h printed | 2.0 L/h4.23 pints/h printed |
| Announced heating / cooling range | −27 to 24 °C / −10 to 46 °C | −25 to 18 °C / −10 to 48 °C |
LG: the Canadian brochure prints the same depth (10 7/16 in) for the indoor and the outdoor unit; confirm the outdoor unit depth in the installation manual before choosing a bracket. LG's heating range is given in wet-bulb temperature; an optional kit (wind and low temperature) allows cooling down to −18 °C according to LG.
Your questions about the Sainte-Thérèse project
Why put the LG ARTCOOL PRESTIGE next to the SHARP ZU1?
Both are 18,000 BTU/h R-32 wall heat pumps, sold by AirGreen and certified for cold climates. The Sainte-Thérèse owner had just renovated his room, so the page first compares how much of the wall each indoor unit takes, then the certified values. It does not rank the two units.
Does the LG go by another name elsewhere?
In the United States, LG publishes the submittal sheet for the same KSSAL181A system (KNSAL181A and KUSAL181A) under the name Art Cool Premier. This page relies on that sheet for the functions, and on the Canadian ARTCOOL Prestige brochure for the figures.
Why is the LG's rated capacity at −8.3 °C lower than at −15 °C?
NEEP certifies 13,100 BTU/h at −8.3 °C and 21,600 BTU/h at −15 °C for the LG's rated capacity. These two values come from different test conditions; the ENERGY STAR database prints the same ones. The page shows the certified values as they are, without linking them.
Does the SHARP ZU1 heat at colder temperatures than the LG?
SHARP announces heating down to −27 °C and NEEP certifies a point at −27.2 °C. LG announces heating down to −25 °C, its last certified point. Below those temperatures, neither manufacturer publishes a capacity.
Does Plasmacluster technology purify the air?
SHARP uses this name for a technology in its brochure; the page repeats the name without crediting it with any effect on health or air quality.
Are these units eligible for LogisVert?
Eligibility and amounts are set by Hydro-Québec and can change. Check each unit's AHRI certificate number in the official list at the time of your project; this page promises no amount.
Behind the design, the AHRI-certified figures
| Certified value (NEEP) | SHARP ZU1 18,000 | LG ARTCOOL PRESTIGE 18,000 |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 24 | 24 |
| EER2 | 13 | 14.4 |
| HSPF2 Region IV | 11 | 11 |
| HSPF2 Region V | 9 | 8.2 |
| Rated capacity at 35 °C (cooling) | 18,000 BTU/h | 18,000 BTU/h |
| Heating, min. / rated / max. capacity | ||
| Min. / rated / max. capacity at 8.3 °C | 5,500 / 21,600 / 25,600 BTU/h | 3,070 / 21,600 / 27,400 BTU/h |
| Min. / rated / max. capacity at −8.3 °C | 7,500 / 22,000 / 22,000 BTU/h | 2,934 / 13,100 / 24,300 BTU/h |
| Min. / rated / max. capacity at −15 °C | 5,800 / 18,000 / 18,000 BTU/h | 2,730 / 21,600 / 21,600 BTU/h |
| Min. / rated / max. COP at 8.3 °C | 5.76 / 4.22 / 3.68 | 1.36 / 4.11 / 2.84 |
| Min. / rated / max. COP at −15 °C | 2.93 / 2.2 / 2.2 | 1.33 / 1.9 / 1.9 |
| Coldest point published by NEEP | ||
| Test temperature | −27.2 °C (−17 °F) | −25 °C (−13 °F) |
| Min. / max. capacity | 3,200 / 11,500 BTU/h | 2,218 / 14,780 BTU/h |
| COP at maximum | 1.88 | 1.44 |
| Documents | ||
| AHRI certificate · NEEP record | 213246053 · 507396 | 215828275 · 385473 |
| ENERGY STAR | Yes; cold climate: yes | Yes; cold climate: yes |
| Refrigerant | R-32, GWP 675 (IPCC AR4), A2L class | R-32, GWP 675 (IPCC AR4), A2L class |
"higher" marks the higher value of a same measurement, under the same conditions. It is not a recommendation. Capacities at different temperatures and the coldest point are never marked.
A renovated room like the one in Sainte-Thérèse? Let's talk.
For a renovated room like the one in Sainte-Thérèse, or for any other question about these two units, call or write to us.
Documents consulted
Data verified on November 17, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, airflow, piping and functions: per the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. SHARP, ZU1, Plasmacluster, LG, ARTCOOL, ThinQ and LGRED are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for both brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us: every reported figure is re-checked.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).