Head to head · Wall-mounted heat pumps

Wall-mounted heat pump GREE Sapphire (EXTRÊME R32) vs LG ARTCOOL Mirror R32: two “design” units compared

11 min
Comparison · “Design” wall unit · 12,000 BTU

GREE EXTRÊME R32 (SAPPHIRE) and LG ARTCOOL MIRROR R32, the look and the numbers

Two 12,000 BTU wall units on R-32 that people often pick for their front panel: one silver-grey, the other black with a mirror finish. They also differ in their size on the wall and in their certified values, which this page shows side by side, with no ranking.

SEER2 29.5 and 22.5 HSPF2 Region V 8.0 and 8.0 Depth from the wall 10 1/8 and 7 9/16 in Coldest points −30 and −20 °C

Article published on April 17, 2025 · rewritten on November 16, 2026 with the AirGreen comparison-page method.

GREE EXTRÊME R32 12,000 BTU (AirGreen image)
GREE

EXTRÊME R32 12,000 BTU

GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O · AHRI 215386290

Also sold as GREE SAPPHIRE R32 (same NEEP certified values) and GREE AIRY R32 (same AHRI certificate).

See the product page
LG ARTCOOL MIRROR R32 12,000 BTU (AirGreen image)
LG

ARTCOOL MIRROR R32 12,000 BTU

KNUAK121A / KUSAB121A · AHRI 215413008

Same AHRI and NEEP certified values as the LG DUALCOOL R32 12,000 BTU (same outdoor unit, different indoor unit).

See the product page
Estimated running cost

What the electricity costs, in dollars, winter and summer

Two wall units chosen first for their looks, brought back here to the bill: a 12,000 BTU/h zone in Montréal, Hydro-Québec Rate D, taxes included, and the same calculation as on all our comparison pages. Only the certified efficiencies change; electric baseboards serve as the reference.

Their HSPF2 Region V values are identical (8.0), so winter costs the same with either one. The gap comes from summer, where their SEER2 values differ (29.5 and 22.5).

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal's design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: a simplification that does not account for the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the value from the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump can no longer keep up. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.

On your wall

Two front panels, two sizes: to scale, on the wall of your choice

Pick a wall colour. The width of each indoor unit is to scale, from the dimensions its manufacturer publishes; each square of the grid is 1 foot (12 in). The photos are those of each model's AirGreen product page.

GREE EXTRÊME R32

38 3/16 × 13 21/32 × 10 1/8 in (width × height × depth), 33.1 lb, per GREE brochure 032025. Silver-grey front panel in the photo on the AirGreen product page.

LG ARTCOOL MIRROR R32

32 15/16 × 12 1/8 × 7 9/16 in (width × height × depth), 22.7 lb, per the LG submittal. Black front panel with a mirror finish, hence the name “Mirror” LG gives the model.

Side view: how far it sticks out from the wall

Drawing to scale, side view (published height and depth). Depth matters in a hallway, above a bed or near a beam; height, above a window or a door.

Extreme cold

Below −15 °C, what each manufacturer publishes, point by point

The round points come from the NEEP record of each AHRI certificate. When a temperature has no published point, the table shows the two published values on either side of it, each with its own temperature; after a model's last point, it repeats that last point and what the manufacturer states beyond it.

91%at −8.3 °C (17 °F) · 12,400 BTU/h
74%at −15 °C (5 °F) · 10,000 BTU/h
59%at −20 °C (−4 °F) · 8,010 BTU/h

Strip above: percentages printed by LG in the ARTCOOL MIRROR R32 submittal (maximum capacity relative to the rated capacity of 13,600 BTU/h at 8.3 °C); the line marks 100%. GREE publishes no equivalent table for the EXTRÊME R32: its service manual gives a percentage curve without stating the base, shown as a note in the table.

How to read this table. At −15 °C, both NEEP records give a value at the same temperature: 12,200 BTU/h for the EXTRÊME R32 and 10,000 BTU/h for the ARTCOOL MIRROR R32. Further down, their last certified points are not at the same temperature (−30 °C and −20 °C) and do not compare directly. Montréal's design temperature is −23.1 °C (Natural Resources Canada, HOT2000).
Features

What each manufacturer writes, line by line

A feature missing from a document is not necessarily missing from the unit: “Not published by the manufacturer” means we found it in none of the manufacturer's documents.

FeatureEXTRÊME R32ARTCOOL MIRROR R32
Base pan heaterYes; 72 W, on below 1 °C or during defrost NEEP record 389444Yes; 90 W, on at 0 °C and below in heating mode NEEP record 389312
Wi-Fi appYes; Wi-Fi connectivity brochure 032025, app not namedYes; ThinQ, built-in Wi-Fi LG submittal
Filter and cleaningYes; washable dust filters brochure 032025Yes; self-cleaning indoor coil, 3M Micro filter LG submittal
CompressorTwo-stage, variable speed brochure 032025Twin rotary brochure 04_25
Remote controlYes; wireless, YBE1FB1F brochure 032025Yes; wireless, AKB76044208 LG submittal
Refrigerant leak sensorNot published by the manufacturer brochure 032025Yes; R-32 sensor in the indoor unit brochure 04_25
Low-voltage start-upYes brochure 032025Not published by the manufacturer brochure 04_25, submittal
Cooling in cold weatherDown to −29 °C stated range, brochure 032025Down to −10 °C; −18 °C with the optional wind baffle kit brochure 04_25
Sound

Indoor unit sound, according to each manufacturer

Indoor unit, published sound pressure

Each point is a published fan speed. Further left = quieter.

dB(A)

How to read these figures. A dB(A) measures a sound level weighted the way the ear hears it; 10 dB(A) more is heard as roughly twice as loud. GREE publishes eight values without naming the speeds or the method; LG publishes three in heating, measured with its own method.

Why this is not a ranking. Without a common distance or method, the two scales do not compare point by point: they show each unit's stated range.

Measured by each manufacturer with its own method: different methods — not comparable point by point.

Installation

Piping, outdoor unit and electrical

The indoor units below are at the same scale. Neither GREE nor LG publishes, in the documents found for these two models, a clearance drawing for the outdoor unit; the installer follows the manual supplied with the unit.

Indoor units to scale

EXTRÊME R3238 3/16 in wide
GREE EXTRÊME R32 indoor unit to scale
38 3/16 in
ARTCOOL MIRROR R3232 15/16 in wide
LG ARTCOOL MIRROR R32 indoor unit to scale
32 15/16 in
Installation, per the manufacturers' documentsEXTRÊME R32ARTCOOL MIRROR R32
Maximum piping length131.2 ft brochure 032025; the Airy service manual states 65.6 ft82 ft minimum 9.8 ftLG submittal
Precharged lengthNot published by the manufacturer brochure 03202541 ft 0.16 oz per ft beyondLG submittal
Maximum height difference82 ft brochure 032025; the service manual states 32.8 ft49.2 ft LG submittal
Liquid – gas line diameters1/4 – 1/2 in1/4 – 3/8 in
Outdoor unit W × H × D, weight34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb30 5/16 × 21 15/32 × 11 11/32 in, 68.8 lb
Indoor unit, weight38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb32 15/16 × 12 1/8 × 7 9/16 in, 22.7 lb
Electrical protectionMCA 11 A · MOP 15 AMCA 12 A · MOCP 15 A
Dehumidification1.4 L/h1.3 L/h 2.75 US pt/h according to LG
Stated heating / cooling range−30 to 30 °C / −29 to 50 °C−20 to 18 °C / −10 to 48 °C heating in wet bulb
Questions

What people ask us about these two models

GREE SAPPHIRE and GREE EXTRÊME R32: what is the difference?

NEEP lists the GREE SAPPHIRE R32, the GREE AIRY R32 and the GREE EXTRÊME R32 in the same “Airy” series. At 12,000 BTU, the AIRY and the EXTRÊME share the same AHRI certificate (215386290), and the SAPPHIRE carries the same NEEP certified values. AirGreen offers this platform under the name EXTRÊME R32. The certificate describes neither the look of the indoor unit nor the remote: check the photo and the model number of the product offered.

LG's ARTCOOL MIRROR and DUALCOOL R32: is the performance the same?

Yes for the certified values: both combinations use the KUSAB121A outdoor unit and their NEEP records (389312 and 389313) carry the same values. Only the indoor unit changes: KNUAK121A, mirror front, for the ARTCOOL MIRROR, and KNUAB121A for the DUALCOOL. The choice between the two comes down to looks.

For a dark wall or a light wall, which one should I choose?

This page does not choose for you. The “On your wall” section shows both front panels on five wall colours, to scale. The EXTRÊME R32 is wider (38 3/16 in) and deeper (10 1/8 in); the ARTCOOL MIRROR R32 is 32 15/16 in wide and 7 9/16 in deep.

Why is the winter cost the same for both?

The AirGreen method calculates winter with the HSPF2 Region V from the AHRI certificate. Both models have 8.0. With equal seasonal efficiency, the winter estimate is identical; the gap comes from cooling (SEER2 29.5 and 22.5).

What does LG publish below −20 °C for the ARTCOOL MIRROR R32?

Its last NEEP certified point is at −20 °C (−4 °F): 8,010 BTU/h maximum, COP 1.79. LG states a heating range down to −20 °C (wet bulb) and publishes no colder capacity for this model. For the EXTRÊME R32, NEEP certifies a point at −30 °C: 8,500 BTU/h maximum, COP 1.75.

Are these models eligible for Hydro-Québec programs?

The front panel changes nothing for eligibility: the AHRI certificate numbers do, 215386290 for the GREE and 215413008 for the LG, to look up on Hydro-Québec's official list. This page promises no amount and no eligibility; the list in force on the purchase date is the reference.

Certified data

The AHRI certificate values, published by NEEP

Certified valueEXTRÊME R32ARTCOOL MIRROR R32
Seasonal efficiencies
SEER229.522.5
EER215.212.8
HSPF2 Region IV10.010.5
HSPF2 Region V8.08.0
Rated capacity at 35 °C (cooling)12,000 BTU/h12,000 BTU/h
Heating, min. / rated / max. capacity (BTU/h)
Min. / rated / max. capacity at 8.3 °C3,270 / 12,200 / 16,2001,023 / 13,600 / 19,040
Min. / rated / max. capacity at −8.3 °C2,800 / 13,000 / 13,0001,877 / 8,500 / 12,400
Min. / rated / max. capacity at −15 °C2,600 / 12,200 / 12,2001,706 / 10,000 / 10,000
Min. / rated / max. COP at 8.3 °C5.04 / 4.53 / 3.771.50 / 3.83 / 2.83
Min. / rated / max. COP at −8.3 °C4.32 / 2.06 / 2.061.49 / 2.86 / 2.19
Min. / rated / max. COP at −15 °C4.23 / 2.00 / 2.001.43 / 1.99 / 1.99
Coldest point (different temperatures)
Test temperature−30 °C (−22 °F)−20 °C (−4 °F)
Max. capacity at the coldest point8,500 BTU/h8,010 BTU/h
Max. COP at the coldest point1.751.79
Certification
RefrigerantR-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)
ENERGY STAR · cold climateYes NEEP, Nov. 16, 2026Yes NEEP, Nov. 16, 2026
AHRI certificate · NEEP record215386290 · 389444215413008 · 389312

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.

Both are on the AirGreen website.

A free estimate visit lets us measure the wall, the line-set length and the outdoor unit location before you pick a front panel.

Sources

Documents consulted

NEEP, record 389444 (AHRI 215386290)GREE GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O, “Airy” series · consulted on Nov. 16, 2026
NEEP, record 389312 (AHRI 215413008)LG KNUAK121A / KUSAB121A · consulted on Nov. 16, 2026
NEEP, record 389313 (AHRI 215413007)LG KNUAB121A / KUSAB121A (DUALCOOL R32) · consulted on Nov. 9, 2026
GREE Canada, “EXTREME R32” brochure, single zoneDOCUMENT NO. 032025 (2025) · consulted on Nov. 9, 2026
GREE, Airy Inverter R32 service manual“Capacity Variation Ratio” curve, 12K, 21.1 °C indoors · read from the PDF's vector paths (±1 point) · consulted on Nov. 9, 2026
LG, ARTCOOL Mirror brochure (FR)PO_LG_R32_ArtCool_Mirror_04_25_CA_FR (2025) · consulted on Nov. 9, 2026
LG Electronics U.S.A., KSUAK121A submittalSB_SZ_ArtCoolMirror_R32_KSUAK121A, version of Feb. 18, 2026 · consulted on Nov. 16, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · consulted on Nov. 9, 2026
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C base), design temperature −23.1 °C · consulted on Nov. 9, 2026

Going further

You made it to the end.Share it with someone it could help.

Leave a comment