SAMSUNG WindFree MaxHeat and LG ARTCOOL MIRROR R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · wall-mounted heat pump · 12,000 BTU

SAMSUNG WindFree MaxHeat and LG ARTCOOL MIRROR R32: two front panels, two certified data sheets

One has a white micro-perforated panel, the other a black mirror finish. The choice of a front panel is yours; this page shows both at the same scale, then what the AHRI certificates published by NEEP and the SAMSUNG and LG documents say.

SEER224.0·22.5
HSPF2 Region V8.5·8.0
Max. at −15 °C, certified9,000·10,000
Coldest NEEP point−30 °C·−20 °C

In each pair: SAMSUNG WindFree MaxHeat first, LG ARTCOOL MIRROR R32 second. Values from the AHRI certificates published by NEEP; capacities in BTU/h.

SAMSUNG WindFree MaxHeat R32 12,000 BTU (AirGreen image) SAMSUNG

WindFree MaxHeat R32 · 12,000 BTU

AR12DXDABWKN / AR12DXDACWKX · AHRI 215399291

See the product page
LG ARTCOOL MIRROR R32 12,000 BTU (AirGreen image) LG

ARTCOOL MIRROR R32 · 12,000 BTU

KNUAK121A / KUSAB121A · AHRI 215413008

Named “ARTCOOL Mirror” in LG's documents. Same outdoor unit (KUSAB121A) and same AHRI and NEEP certified values as the LG DUALCOOL R32 (KNUAB121A, AHRI certificate 215413007).

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal's design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: a simplification that does not account for the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the value from the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump can no longer keep up. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.

The front panel

On the same wall, at the same scale

The photos show the actual units, at the same scale: 1 in on one measures the same as 1 in on the other. Change the light in the room, then look at the air outlet each manufacturer describes in its documents.

Room light
Air outlet described by the manufacturer
WindFree MaxHeat R32 · SAMSUNG
SAMSUNG WindFree MaxHeat R32 indoor unit, white micro-perforated panel
35 in · 889 mm
ARTCOOL MIRROR R32 · LG
LG ARTCOOL MIRROR R32 indoor unit, black mirror finish
32 15/16 in · 837 mm
WindFree MaxHeat R32
ARTCOOL MIRROR R32

The lines and dots under each unit are a diagram, not an airflow measurement. The “Evening” light only darkens the scene; the photos remain the manufacturers' own. Widths per SAMSUNG submittal 10072024A and LG brochure 04_25 (837 mm: converted from 32 15/16 in).

What SAMSUNG documents about the front panel

  • White, micro-perforated front panel (manufacturer's photo).
  • WindFree mode: in cooling, the air is dispersed through the micro-perforations, according to SAMSUNG (submittal 10072024A).
  • Display to the right of the louver, visible in the photo; how it turns off is not described in the submittal consulted.
  • 35 × 11 3/4 × 8 7/16 in (width × height × depth).

What LG documents about the front panel

  • Black front panel with a mirror finish (manufacturer's photo).
  • LG brochure (French edition, our translation): mirror-finish units that blend into a modern décor.
  • Display: not described in the brochure or the submittal consulted.
  • 32 15/16 × 12 1/8 × 7 9/16 in (width × height × depth).
The front panel is not rankedMicro-perforated white or mirror black: it is a matter of taste and décor. This page does not say which one looks better.
Two inches apartThe WindFree MaxHeat is 2 1/16 in wider; the ARTCOOL MIRROR is 3/8 in taller and 7/8 in shallower, according to the manufacturers.
The finish does not change the data sheetThe efficiencies and capacities come from each unit's AHRI certificate. They are further down the page, line by line.
Extreme cold

Below −15 °C: every published value, unit by unit

NEEP certifies the WindFree MaxHeat at −15 and −30 °C, and the ARTCOOL MIRROR at −15 and −20 °C. SAMSUNG's Technical Data Book adds average values at −15, −20.6 and −30 °C. LG states a heating range that stops at −20 °C and publishes no colder capacity. Between two published values, we show the range; nothing is calculated.

At −15 °C, both units have a value of the same kind (maximum certified by NEEP): it is the only row of this table that compares directly. At −20 °C, LG has a certified point and SAMSUNG a range between two values from different sources. At −30 °C, only the SAMSUNG record has a value; for the ARTCOOL MIRROR, we repeat the last published point, at −20 °C.

The ARTCOOL MIRROR's maximum capacity, as a percentage of its rated capacity

91%at −8 °C · 12,400 BTU/h
74%at −15 °C · 10,000 BTU/h
59%at −20 °C · 8,010 BTU/h

According to LG brochure PO_LG_R32_ArtCool_Mirror_04_25_CA_FR: maximum heating capacity relative to the rated capacity of 13,600 BTU/h; the vertical line marks 100%. These three capacities are also the maximums certified by NEEP at −8.3, −15 and −20 °C. SAMSUNG does not publish an equivalent percentage in the documents consulted; its submittal mentions “100% heating capacity at −4 °F”, without stating the base.

Features

What each manufacturer writes, feature by feature

Only the features named in the documents consulted are listed. When a document says nothing about one, we say so: that does not mean the feature does not exist.

Heating in extreme cold
SAMSUNG: base pan heater as standard; stated heating range −30 to 24 °C; “100% heating capacity at −4 °F”, according to SAMSUNG.LG: “Built-in Drain pan heater”; stated heating range −20 to 18 °C (wet bulb).

SAMSUNG states 10 °C more toward the cold; that is an operating range, not a capacity.

Air distribution and louver
SAMSUNG: WindFree mode, air dispersed through micro-perforations in cooling.LG: “4-Way auto swing”, “Jet Cool/Jet Heat”; the French brochure adds four automatic louver angles and a random airflow mode.

How each manufacturer describes the air outlet.

Maintenance and cleaning
SAMSUNG: Auto Clean, washable filter.LG: “Self-cleaning indoor coil”, “3M Micro Filter”.

Both manufacturers name an automatic cleaning of the indoor unit.

Wi-Fi app
SAMSUNG: built-in Wi-Fi, SmartThings app.LG: “Built-in Wi-Fi via ThinQ app”; Smart Diagnosis.

Both submittals describe built-in Wi-Fi.

Compressor
SAMSUNG: twin BLDC rotary, inverter.LG: twin rotary, inverter.

Both manufacturers describe a variable-speed twin rotary compressor.

Remote control
SAMSUNG: rechargeable remote (solar or USB-C).LG: wireless remote AKB76044208, included.

Each submittal names the remote supplied.

Refrigerant leak detection
SAMSUNG: not stated in the submittal consulted.LG: R-32 leak sensor in the indoor unit, with an alert.

LG names it in its brochure and its submittal; a document's silence does not prove absence.

Operating modes
SAMSUNG: AI Auto, AI Energy, Eco, Quiet, Good'sleep.LG: “Sleep Mode”, 24-hour timer, “Auto Restart”, “Auto Changeover”.

Names given by each manufacturer; the modes are not one-to-one equivalents.

Cooling in cold weather
SAMSUNG: stated cooling down to −18 °C.LG: down to −10 °C; down to −18 °C with the optional wind baffle kit.

Useful for a room that needs cooling even in winter; these are stated ranges.

Documented featureWindFree MaxHeat R32ARTCOOL MIRROR R32
Base pan heaterYes standard; 150 W, starts at −8 °C in heating per the NEEP recordYes built in; 90 W, on at 0 °C and below in heating mode per the NEEP record
Wi-Fi appYes SmartThings, built-in Wi-FiYes ThinQ, built-in Wi-Fi (LG submittal)
Filter and automatic cleaningYes Auto CleanYes Self-cleaning indoor coil; 3M Micro Filter
CompressorTwin BLDC rotary submittal 10072024ATwin rotary brochure 04_25
Remote controlYes rechargeable, solar or USB-CYes wireless, AKB76044208
Refrigerant leak sensorNot published by the manufacturer submittal 10072024AYes R-32 sensor in the indoor unit
Cooling in cold weatherDown to −18 °C stated rangeDown to −10 °C −18 °C with the optional wind baffle kit
Sound

Indoor unit sound, fan speed by fan speed

Published indoor sound pressure

Each point is one fan speed published by the manufacturer.

dB

How to read these figures. The lower the decibel figure, the quieter the unit. Each point is one published fan speed. A rise of 10 dB(A) is heard as roughly twice as loud.

Why this is not a ranking. SAMSUNG publishes only the lowest and the highest speed, without stating the test method in the submittal consulted. LG publishes each speed and specifies a test in an anechoic chamber under ISO Standard 3745, to ±1 dB(A).

Measured by each manufacturer with its own method: different methods — not comparable point by point.

Installation

Is your wall wide enough?

Move the slider to the free width of your wall. Both photos stay at the same scale.

40 in
WindFree MaxHeat R32

ARTCOOL MIRROR R32

Width of the unit only, per the manufacturer. The clearances around the indoor unit are given in each manufacturer's installation manual.

Installation, according to the manufacturers' documentsWindFree MaxHeat R32ARTCOOL MIRROR R32
Maximum piping length66 ft82 ft minimum 9.8 ft
Precharged length24.6 ft41 ft 0.16 oz per ft beyond
Maximum height difference49 ft49.2 ft
Liquid – gas line diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight31 1/8 × 21 9/16 × 11 1/4 in, 71 lb30 5/16 × 21 15/32 × 11 11/32 in, 68.8 lb
Indoor unit, weight35 × 11 3/4 × 8 7/16 in, 23.1 lb32 15/16 × 12 1/8 × 7 9/16 in, 22.7 lb
Electrical protectionMCA 12 A · max. breaker 20 AMCA 12 A · MOCP 15 A
DehumidificationNot published by the manufacturer1.3 L/h 2.75 US pt/h according to LG
Stated heating / cooling range−30 to 24 °C / −18 to 46 °C−20 to 18 °C / −10 to 48 °C heating in wet bulb
Questions

Questions about this pair

Does the mirror finish change the performance?

No. The finish concerns the front panel of the indoor unit. The certified values of the ARTCOOL MIRROR R32 are those of AHRI certificate 215413008; the LG DUALCOOL R32, connected to the same KUSAB121A outdoor unit, has the same AHRI and NEEP certified values under certificate 215413007.

What is WindFree mode?

According to SAMSUNG, in cooling, the air is dispersed through the micro-perforations of the front panel rather than through the louver. That is the manufacturer's description; this page does not measure comfort.

Which one delivers more heat at −15 °C?

At −15 °C, same temperature and same source: 10,000 BTU/h maximum for the ARTCOOL MIRROR R32 (COP of 1.99) and 9,000 BTU/h for the WindFree MaxHeat (COP of 2.09), according to NEEP.

And below −20 °C?

The WindFree MaxHeat certificate has a point at −30 °C: 6,800 BTU/h maximum, with a COP of 1.73. The coldest point of the ARTCOOL MIRROR R32 is at −20 °C: 8,010 BTU/h, with a COP of 1.79. LG states a heating range of −20 to 18 °C and publishes no colder capacity for this model.

Which one costs less to run?

With our method, the WindFree MaxHeat needs slightly less electricity: Region V HSPF2 of 8.5 versus 8.0, SEER2 of 24.0 versus 22.5. The “Cost by season” module shows the exact difference for your hours of use.

Are the two indoor units the same width?

No: 35 in for the WindFree MaxHeat and 32 15/16 in for the ARTCOOL MIRROR R32, according to the manufacturers.

What about the warranty?

Each manufacturer publishes its own terms. The warranty documents come with the quote.

Certified data

AHRI certificate values, as published by NEEP

Certified valueWindFree MaxHeat R32ARTCOOL MIRROR R32
Seasonal efficiencies
SEER224.022.5
EER214.112.8
HSPF2 Region IV10.510.5
HSPF2 Region V8.58.0
Rated capacity at 35 °C (cooling)12,000 BTU/h12,000 BTU/h
Heating, min. / rated / max. capacity
Min. / rated / max. capacity at 8.3 °C2,600 / 12,000 / 15,5001,023 / 13,600 / 19,040
Min. / rated / max. capacity at −8.3 °C1,600 / 10,600 / 10,6001,877 / 8,500 / 12,400
Min. / rated / max. capacity at −15 °C2,400 / 9,000 / 9,0001,706 / 10,000 / 10,000
Min. / rated / max. COP at 8.3 °C4.76 / 4.34 / 3.361.50 / 3.83 / 2.83
Min. / rated / max. COP at −8.3 °C3.61 / 2.82 / 2.271.49 / 2.86 / 2.19
Min. / rated / max. COP at −15 °C2.93 / 2.09 / 2.091.43 / 1.99 / 1.99
Coldest point (different temperatures)
Test temperature−30 °C (−22 °F)−20 °C (−4 °F)
Max. capacity at the coldest point6,800 BTU/h8,010 BTU/h
Max. COP at the coldest point1.731.79
Certification
RefrigerantR-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)
ENERGY STAR · cold climateYes NEEP, Nov. 9, 2026Yes NEEP, Nov. 9, 2026
AHRI certificate · NEEP record215399291 · 389387215413008 · 389312

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation.

Both are on the AirGreen site.

For an estimate visit or a quote on either of these units.

Sources

Documents consulted

NEEP, record 389387 (AHRI 215399291)SAMSUNG AR12DXDABWKN / AR12DXDACWKX · accessed Nov. 9, 2026
NEEP, record 389312 (AHRI 215413008)LG KNUAK121A / KUSAB121A · record updated Nov. 6, 2026 · accessed Nov. 9, 2026
NEEP, record 389313 (AHRI 215413007)LG KNUAB121A / KUSAB121A (DUALCOOL R32) · accessed Nov. 9, 2026
SAMSUNG, Submittal Data AR12DXDABWKNCV / AR12DXDACWKXCV, WindFree Max Heatversion 10072024A · accessed Nov. 9, 2026
SAMSUNG, Technical Data Book “RAC for North America R32”, v1.2heating capacity table RNX12ABD + RXX12ACD, p. 25, 21.1 °C indoors, average values · accessed Nov. 9, 2026
LG, ARTCOOL Mirror, brochure (FR)PO_LG_R32_ArtCool_Mirror_04_25_CA_FR (2025) · accessed Nov. 9, 2026
LG, Submittal KSUAK121A, R32 Single Zone Art Cool Mirror Wall MountedSB_SZ_ArtCoolMirror_R32_KSUAK121A, version of Feb. 18, 2026 · accessed Nov. 9, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, s. 2.5
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days, −23.1 °C