SAMSUNG WindFree Standard R32 and WindFree MaxHeat R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · SAMSUNG · 12,000 BTU

SAMSUNG WindFree Standard R32 and WindFree MaxHeat R32: what changes from one series to the other

Two 12,000 BTU SAMSUNG series, with the same seasonal cooling efficiency (SEER2 24.0) and the same HSPF2 Region V (8.5). What sets them apart shows up in the cold: the WindFree Standard is certified down to −20.6 °C, the WindFree MaxHeat down to −30 °C. Here is what “MaxHeat” adds, according to the certificates and SAMSUNG’s documents.

SEER224.0·24.0
HSPF2 Region IV9.0·10.5
Max. at −15 °C, certified8,000·9,000
Coldest NEEP point−20.6 °C·−30 °C
SAMSUNG WindFree Standard R32 12,000 BTU (AirGreen image) SAMSUNG

WindFree Standard R32 · 12,000 BTU

AR12DXFAMWKN / AR12DXFAMWKX · AHRI 215399297

See the product page
SAMSUNG WindFree MaxHeat R32 12,000 BTU (AirGreen image) SAMSUNG

WindFree MaxHeat R32 · 12,000 BTU

AR12DXDABWKN / AR12DXDACWKX · AHRI 215399291

See the product page
WindFree Standarddown to −20.6 °C
WindFree MaxHeatdown to −30 °C

Span of the test temperatures certified by NEEP, starting at 8.3 °C. Key: SAMSUNG blue for the Standard, AirGreen green for the MaxHeat.

Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

Why the two amounts are identical. Our method uses two values from the AHRI certificate: HSPF2 Region V for winter and SEER2 for summer. Both series have exactly the same ones (8.5 and 24.0). The difference between them therefore does not show in this seasonal calculation; it shows in the heating range and in the extreme-cold test points, below.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal’s design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the value of the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump can no longer keep up. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.

The certified zone

Two certified curves, one that stops earlier

Each point is a NEEP-certified value. The shaded zone under each curve extends to the record’s last test point: −20.6 °C for the WindFree Standard, −30 °C for the WindFree MaxHeat.

WindFree Standard R32 SAMSUNGWindFree MaxHeat R32 SAMSUNG
At −15 °C, same sourceNEEP certifies 9,000 BTU/h maximum for the MaxHeat and 8,000 BTU/h for the Standard, with COPs of 2.09 and 1.76.
The last-point trapThe Standard shows 10,000 BTU/h at −20.6 °C and the MaxHeat 6,800 BTU/h at −30 °C. The larger value was measured 9.4 °C warmer: these two figures do not compare.
A value that goes back upThe Standard’s NEEP record publishes 10,000 BTU/h at −20.6 °C, more than at −15 °C (8,000). We show it as published.
Extreme cold

Below −15 °C: where each series was measured

NEEP certifies the WindFree Standard at −15 and −20.6 °C, the WindFree MaxHeat at −15 and −30 °C. For the MaxHeat, the SAMSUNG Technical Data Book v1.2 adds average values. Below the Standard’s last point, we show that last value and the heating range SAMSUNG states.

At −20.6 °C, both units have a value, but not of the same kind: a NEEP-certified point for the Standard (10,000 BTU/h maximum), a Technical Data Book average value for the MaxHeat (12,300 BTU/h). At −15 °C, both are NEEP certified. At −30 °C, only the MaxHeat has published values.

Same chassis?

What SAMSUNG’s documents allow us to say

The two units look alike in the photos. The question is what they really share. We answer only with the model numbers and the values published by SAMSUNG and NEEP.

What is identical
  • SEER2 24.0 and HSPF2 Region V 8.5 (AHRI certificates).
  • Rated cooling capacity: 12,000 BTU/h.
  • R-32 refrigerant.
  • WindFree mode and SmartThings app, per SAMSUNG.
What differs
  • Indoor unit: AR12DXFAMWKN (Standard) and AR12DXDABWKN (MaxHeat).
  • Outdoor unit: AR12DXFAMWKX and AR12DXDACWKX.
  • AHRI certificates: 215399297 and 215399291; NEEP series “WindFree - Standard (RAC)” and “WindFree - Max heat (RAC)”.
  • Heating range: down to −20.5 °C (Standard) and −30 °C (MaxHeat); cooling down to −10 °C and −18 °C.
  • HSPF2 Region IV: 9.0 and 10.5.

Our reading. The indoor and outdoor model numbers differ at SAMSUNG. The documents we read do not allow us to say it is the same chassis; they show two separate combinations, with two separate certificates.

Features

What each manufacturer writes, feature by feature

Only the features named in the documents we read are listed. When a document says nothing about one, we say so: that does not mean the feature does not exist.

Heating range
Standard: −5 to 75 °F (−20.5 to 24 °C), per SAMSUNG.MaxHeat: −22 to 75 °F (−30 to 24 °C), per SAMSUNG.

The main difference between the two series.

Cooling in cold weather
Standard: down to 14 °F (−10 °C) outdoors.MaxHeat: down to 0 °F (−18 °C) outdoors.

Useful for a room that overheats in the shoulder season.

Base pan heater
Standard: neither the SAMSUNG page nor the NEEP record lists one.MaxHeat: standard, per the submittal sheet.

Helps defrost water drain instead of freezing.

Backup heat for extreme cold
Standard: “Emergency Heat Operation” and “Smart Heat Source Management” on the SAMSUNG page.MaxHeat: control of an external heat source with the MIM-B14U accessory, per the sheet.

Managing backup heat in extreme cold.

WindFree mode
Standard: cooling without a direct draft, per SAMSUNG.MaxHeat: louver closed, air diffused through micro-holes.

Same principle in both series, per SAMSUNG.

App and remote control
Standard: SmartThings; solar-cell wireless remote included.MaxHeat: built-in Wi-Fi, SmartThings; rechargeable remote, solar or USB-C.

To adjust the unit remotely.

Documented featureWindFree Standard R32WindFree MaxHeat R32
Stated heating / cooling range−20.5 to 24 °C / −10 to 46 °C−30 to 24 °C / −18 to 46 °C
Base pan heaterNot published by the manufacturer SAMSUNG page and NEEP recordYes standard; 150 W, starts at −8 °C in heating per the NEEP record
Wi-Fi appYes SmartThingsYes SmartThings, built-in Wi-Fi
Remote controlYes solar cellYes solar cell or USB-C
WindFree mode, cooling without a draftYesYes
Sound

Indoor unit sound, fan speed by fan speed

Published indoor sound pressure

Each point is a fan speed published by SAMSUNG.

WindFree Standard R32 : SAMSUNG does not publish the sound pressure of the 12,000 BTU model in the documents we could find (series page, no 12K submittal sheet). We do not reuse a figure from another source.

dB

How to read these figures. The lower the decibels, the quieter the unit. Each point is one published fan speed. A rise of 10 dB(A) is heard as roughly twice as loud.

Why this is not a ranking. Only one of the two units has a published value in the documents we read; there is nothing to put side by side.

Measured by each manufacturer with its own method: only one of the two series has a published value here.

Installation

Installation: what SAMSUNG publishes for each series

SAMSUNG’s submittal sheet for the WindFree MaxHeat (version 10072024A) gives every installation figure. For the 12,000 BTU WindFree Standard, we found no public SAMSUNG submittal sheet; the series page gives only the operating ranges. The empty cells say so, rather than repeating an unverified figure.

Installation, per the manufacturers’ documentsWindFree Standard R32WindFree MaxHeat R32
Maximum piping lengthNot published by the manufacturer SAMSUNG documents consulted66 ft
Precharged lengthNot published by the manufacturer SAMSUNG documents consulted24.6 ft
Maximum height differenceNot published by the manufacturer SAMSUNG documents consulted49 ft
Liquid – gas line diametersNot published by the manufacturer SAMSUNG documents consulted1/4 – 3/8 in
Outdoor unit W × H × D, weightNot published by the manufacturer SAMSUNG documents consulted31 1/8 × 21 9/16 × 11 1/4 in, 71 lb
Indoor unit, weightNot published by the manufacturer SAMSUNG documents consulted35 × 11 3/4 × 8 7/16 in, 23.1 lb
Electrical protectionNot published by the manufacturer SAMSUNG documents consultedMCA 12 A · max. breaker 20 A
Stated heating / cooling range−20.5 to 24 °C / −10 to 46 °C−30 to 24 °C / −18 to 46 °C
Questions

Questions about this pair

What does “MaxHeat” add to the WindFree Standard?

According to SAMSUNG and NEEP: a heating range that goes down to −30 °C instead of −20.5 °C, a certified test point at −30 °C, a higher HSPF2 Region IV (10.5 against 9.0), a base pan heater as standard and cooling possible down to −18 °C outdoors.

Why is the estimated cost the same for both?

Our method uses HSPF2 Region V and SEER2 from the AHRI certificate. Both series have the same values (8.5 and 24.0), hence the same estimate.

Does the Standard heat more at −20.6 °C than the MaxHeat at −30 °C?

These two values do not compare: they were measured 9.4 °C apart. At −15 °C, same temperature and same source, the MaxHeat has the higher value (9,000 against 8,000 BTU/h).

Do the two series share the same AHRI certificate?

No. According to the documents, the indoor and outdoor units carry different SAMSUNG model numbers and the AHRI certificates are separate. Both share the same SEER2 and HSPF2 Region V.

Is the Standard ENERGY STAR cold climate certified?

According to NEEP on November 9, 2026, the 12,000 BTU WindFree Standard (AHRI 215399297) is ENERGY STAR, without the cold climate designation. The WindFree MaxHeat (AHRI 215399291) carries both.

What about the warranty?

SAMSUNG publishes its own terms. The warranty documents come with the quote.

Certified data

AHRI certificate values, as published by NEEP

Certified valueWindFree Standard R32WindFree MaxHeat R32
Seasonal efficiencies
SEER224.024.0
EER213.2514.1
HSPF2 Region IV9.010.5
HSPF2 Region V8.58.5
Rated capacity at 35 °C (cooling)12,000 BTU/h12,000 BTU/h
Heating, min. / rated / max. capacity
Min. / rated / max. capacity at 8.3 °C2,200 / 12,000 / 15,0002,600 / 12,000 / 15,500
Min. / rated / max. capacity at −8.3 °C1,600 / 10,900 / 10,9001,600 / 10,600 / 10,600
Min. / rated / max. capacity at −15 °C2,400 / 8,000 / 8,0002,400 / 9,000 / 9,000
Min. / rated / max. COP at 8.3 °C4.61 / 3.82 / 2.844.76 / 4.34 / 3.36
Min. / rated / max. COP at −15 °C2.93 / 1.76 / 1.762.93 / 2.09 / 2.09
Coldest point (different temperatures)
Test temperature−20.6 °C (−5 °F)−30 °C (−22 °F)
Max. capacity at the coldest point10,000 BTU/h6,800 BTU/h
Max. COP at the coldest point1.811.73
Certification
RefrigerantR-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)
ENERGY STAR · cold climateENERGY STAR yes · cold climate no NEEP, Nov. 9, 2026Yes NEEP, Nov. 9, 2026
AHRI certificate · NEEP record215399297 · 389381215399291 · 389387

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation.

Both are on the AirGreen site.

For an estimate visit or a quote on either of these units.

Sources

Documents consulted

NEEP, record 389381 (AHRI 215399297)SAMSUNG AR12DXFAMWKN / AR12DXFAMWKX · consulted Nov. 9, 2026
NEEP, record 389387 (AHRI 215399291)SAMSUNG AR12DXDABWKN / AR12DXDACWKX · consulted Nov. 9, 2026
SAMSUNG HVAC, WindFree Standard pagesamsunghvac.com/residential/windfree-standard · operating ranges and features · consulted Nov. 9, 2026
SAMSUNG, Submittal Data AR12DXDABWKNCV / AR12DXDACWKXCV, WindFree Max Heatversion 10072024A · consulted Nov. 9, 2026
SAMSUNG, Technical Data Book “RAC for North America R32”, v1.2heating capacity table RNX12ABD + RXX12ACD, 21.1 °C indoors, average values
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days, −23.1 °C