Complete guide

FUJITSU AIRSTAGE, GREE and SHARP wall heat pumps: six checks you can do yourself

—chapters
12min in total
June 2025edition
Thermopompes murales : trois modèles de 12 000 BTU comparés
Comparison · Wall heat pumps · 12,000 BTU

Three brands, one method: what you can check yourself

There is no public standard that measures how reliable a brand is. A certificate, a performance listing and the manufacturer's documents can be checked. This page takes three 12,000 BTU R-32 wall heat pumps sold by AirGreen, one per brand, and puts them through the same six checks, in alphabetical order of brand.

3 models comparedAHRI certificates · NEEP records · ENERGY STAR directoryR-32 refrigerant for all threeNo ranking
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU wall heat pump, indoor and outdoor units FUJITSU AIRSTAGE

ORION XLTH 12,000 BTU

ASUH12KZAS + AOUH12KZAH1
AHRI 214888802 · NEEP 392122
See the product page
GREE EXTRÊME R32 12,000 BTU wall heat pump, indoor and outdoor units GREE

EXTRÊME R32 12,000 BTU

GWH12AVDXE-D6DN***/I + GWH12AVDXE-D6DNA1B/O
AHRI 215386290 · NEEP 389444
See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec's Rate D, taxes included. The heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. The module below shows two of them, in alphabetical order; the table that follows shows all three with the same settings. Electric baseboards serve as the reference point.

All three models, same settings as above

The table follows the price and hours chosen in the module. Same method, same conditions; only each certificate's HSPF2 Region V and SEER2 change.

Winter · heating

Summer · cooling

Full year

How this amount is calculated
  1. Heat needed over the winter. A zone with a heat loss of 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day ("Heating" slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down when the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The method

Six checks anyone can repeat

Pick a check. The panel says where to look, what the document shows and what it answers for each of the three models. These answers apply to the named combination of units, never to a whole brand.

Where

What

Extreme cold

Below −15 °C, what each manufacturer and NEEP publish

Each point comes from a certificate published by NEEP or from a manufacturer document, at its own temperature. Between two published points, the table gives the range with both endpoints; below a unit's last point, the last published value stays on screen with its temperature, followed by what the manufacturer says. Nothing is calculated between points.

Three coldest temperatures, three different places. NEEP certifies the ORION XLTH down to −26.1 °C, the EXTRÊME R32 down to −30 °C and the ZU1 down to −27.2 °C. Only one below-zero temperature is shared by all three certificates, −15 °C: it is the only row where the three values read side by side. GREE also publishes, in the Airy Inverter R32 service manual, a capacity curve in percent without stating its base; it is therefore not converted to BTU/h here.
Documented features

What each manufacturer writes, line by line

FUJITSU AIRSTAGE brochure FG8153C; GREE Canada EXTRÊME R32 brochure (032025), GREE Airy Inverter R32 service manual and the English GREE AIRY R32 brochure, which carry the same model numbers; SHARP "ZU/ZHU" brochure distributed by RBL A/C and the SHARP installation manual for the ZU, ZHU and BU series. "Not published by the manufacturer" means the document consulted is silent, not that the feature is missing.

FeatureORION XLTHEXTRÊME R32ZU1
Wi-Fi and appYes; built-in Wi-Fi, AIRSTAGE Mobile appYes; app not named in the brochureYes; built-in Wi-Fi
Remote controlWireless, backlit, includedModel YBE1FB1FNot published by the manufacturer in the brochure consulted
Restart after a power failureYes; automatic restartYes; resumes the last settings Service manualYes; automatic restart
Heated base panYes; 150 W Declared to NEEPYes; 72 W, below 1 °C or during defrostNot published by the manufacturer; the brochure describes the "Hot Gas Pipe" system, which keeps the drain holes free of ice
DefrostAutomatic"Smart" preheating and defrost GREE AIRY R32 brochurePreheating and defrost modes named in the brochure
Named modesPowerful, Economy, Energy Saving, Minimum Heat, OccupancyG-AI LearningMulti Space, Coanda, sleep timer
Filter and cleaningWashable filterWashable filtersSelf-cleaning function SHARP calls "Plasmacluster"
CompressorInverterG10 Inverter, two-stage variable speedNot named in the brochure; min. and max. capacities certified by NEEP
Refrigerant leak detectorNot published by the manufacturerYes; sensor included GREE AIRY R32 brochureNot published by the manufacturer
Sound

Indoor unit noise, according to each manufacturer

Each dot is a level published for one fan speed. FUJITSU AIRSTAGE and SHARP publish one level per speed in cooling; GREE publishes eight levels, from 19 to 43 dB(A), without naming the speeds: only its two extremes are shown.

Indoor unit, cooling

dB(A), from lowest to highest

dB

How to read these numbers. A lower number means a quieter unit at that speed. Each manufacturer measures with its own method (distance, test room), which the documents consulted do not all detail.

Why this is not a ranking. Without a common method, two numbers from two manufacturers cannot be compared to the decibel.

Measured by each manufacturer with its own method; different methods, values not comparable to the decibel.

Installation

On your wall and out to the outdoor unit

The three indoor units are drawn at their published width. Set the free width of your wall: the strip turns yellow when the unit is wider than the space. Clearances around the head depend on each model's installation manual.

40 in

Each strip stands for 60 in of wall; the light area in the middle is the free width you chose. Widths: brochure FG8153C (ORION XLTH), GREE Canada brochure 032025 (EXTRÊME R32), SHARP ZU series brochure (ZU1).

InstallationORION XLTHEXTRÊME R32ZU1
Max. piping length82 ft131.2 ft Brochure; the manual prints 65.6 ft65.6 ft SHARP installation manual
Pre-charged length49 ft24.6 ft; 0.2 oz/ft beyond25 ft; 0.16 oz/ft beyond
Max. height difference66 ft82 ft Brochure; the manual prints 32.8 ft32.8 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in1/4 – 3/8 in
Indoor unit W × H × D, weight38 9/16 × 11 × 9 7/16 in, 28 lb38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb34 39/64 × 11 3/8 × 9 1/64 in, 22 lb
Outdoor unit W × H × D, weight31 7/16 × 24 7/8 × 11 7/16 in, 86 lb34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb30 23/32 × 21 1/4 × 10 19/32 in, 67 lb
Electrical protection15 A15 A maximum; MCA 11 A15 A maximum fuse
Dehumidification1.9 L/h1.4 L/h1.5 L/h 3.2 pints/h in the brochure
Advertised heating / cooling range−26 to 24 °C / −10 to 50 °C−30 to 30 °C / −29 to 50 °C−27 to 24 °C / −10 to 46 °C

ORION XLTH: brochure FG8153C and manual DR_AS233ES_02. EXTRÊME R32: GREE Canada brochure 032025 and GREE manual (the two documents differ on length and height difference; both values are shown). ZU1: SHARP installation manual for the ZU, ZHU and BU series for piping; SHARP "ZU/ZHU" brochure for the rest.

Certified data

The values on the three certificates

AHRI certificates published by NEEP, consulted November 17, 2026. Capacities and COP read side by side only at the same temperature.

Certified valueORION XLTHEXTRÊME R32ZU1
Certificate
AHRI certificate · NEEP record214888802 · 392122215386290 · 389444213194987 · 507399
RefrigerantR-32R-32R-32
ENERGY STAR · cold climateYes; listing 3554345Yes; listing 3621214Yes; listing 3414510
Seasonal efficiency
SEER230.529.522
EER21615.212.5
HSPF2 Region IV12.71011
HSPF2 Region V10.189
Heating, same test temperatures
Capacity at 8.3 °C, min. / rated / max. (BTU/h)3,500 / 16,000 / 23,6003,270 / 12,200 / 16,2003,200 / 14,000 / 17,100
COP at 8.3 °C, min. / rated / max.5.13 / 4.64 / 3.075.04 / 4.53 / 3.776.25 / 3.98 / 2.78
Capacity at −8.3 °C, min. / rated / max. (BTU/h)2,200 / 10,000 / 18,7002,800 / 13,000 / 13,0003,800 / 14,500 / 14,500
Capacity at −15 °C, min. / rated / max. (BTU/h)1,950 / 16,600 / 16,6002,600 / 12,200 / 12,2002,950 / 12,000 / 12,000
COP at −15 °C, min. / rated / max.3.36 / 2.16 / 2.164.23 / 2.00 / 2.002.88 / 2.11 / 2.11
Coldest point on each certificate (different temperatures)
Test temperature−26.1 °C (−15 °F)−30 °C (−22 °F)−27.2 °C (−17 °F)
Max. capacity (BTU/h)12,2008,5007,200
COP at max. capacity1.811.751.80

No cell is highlighted: with three units, the page leaves the reading to you, row by row. The coldest points are measured at three different temperatures and do not compare with each other.

Questions

What people ask us about brands

Why is no brand named the most reliable?

Because no public standard measures how reliable a brand is. An AHRI certificate, a NEEP record, the ENERGY STAR directory and the manufacturer's documents can be checked; an impression from the field cannot. This page sticks to what can be checked, for three named models.

Why these three models?

The previous version of this article discussed FUJITSU AIRSTAGE (the KZAH series, sold as ORION XLTH), GREE (EXTRÊME and Sapphire) and SHARP (ZU1). The page keeps these three brands and takes from each a 12,000 BTU R-32 wall unit sold by AirGreen. They are shown in alphabetical order of brand.

What about a unit bought online, with no listing?

The six checks on this page apply to any unit, from any brand. Without the full model numbers of both units, there is no AHRI certificate to look up, no NEEP record and no ENERGY STAR listing. That is the first thing to ask for, before the price.

Why does the ORION XLTH NEEP record show GENERAL?

NEEP lists the manufacturer that registered the certificate: GENERAL HVAC Solutions America, Inc. for AHRI certificate 214888802. The series is also sold under the name GENERAL AIRSTAGE, with the same AHRI certificate. On our pages it is called FUJITSU AIRSTAGE ORION XLTH.

Which SHARP document describes the ZU1?

SHARP's installation manual for the ZU, ZHU and BU series lists the AY-XP12ZU1 in the ZU series. The French brochure distributed by RBL A/C prints model AY-XPC12ZU from the same series; its heating capacities at −8.3, −15 and −27 °C are identical to the ZU1 certificate. The page states, row by row, which document it follows.

Why are warranties not compared?

Terms vary with the manufacturer, product registration and purchase date. The warranty documents for the chosen model come with the quote.

Are these models eligible for the LogisVert rebate?

Eligibility depends on Hydro-Québec's list in effect on your purchase date. We check it for the exact model on your quote; no amount is promised on this page.

All three are on AirGreen's website.

Our estimator comes to measure the room and the wall for free, then shows you these same documents for the chosen model. Written quote within 24 hours.

Sources

Documents consulted

NEEP, Cold Climate Air Source Heat Pump ListRecords 392122, 389444 and 507399 (AHRI certificates 214888802, 215386290, 213194987) · consulted November 17, 2026 ENERGY STAR, heat pump directoryListings 3554345, 3621214 and 3414510 · consulted November 17, 2026
FUJITSU AIRSTAGE, ORION XLTH brochureFG8153C, rev. 4/2025 · ranges, "no lockout", features, dimensions
FUJITSU AIRSTAGE, design manualDR_AS233ES_02, §5-2 · capacity at −5 °F and −15 °F, sound, piping
GREE Canada, EXTRÊME R32 brochureDocument 032025 · ranges, piping, dimensions, sound
GREE, Airy Inverter R32 service manual and GREE AIRY R32 brochureSame model numbers · percent capacity curve, restart, leak sensor, defrost
SHARP, installation manual, ZU, ZHU and BU seriesNo code printed · piping, refrigerant · consulted November 17, 2026
SHARP, "ZU/ZHU" brochure (RBL A/C Inc.)Undated, model AY-XPC12ZU / AE-X12ZU · capacities by temperature, ranges, dimensions, sound, features
Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design · consulted November 17, 2026