FUJITSU AIRSTAGE ORION XLTH and GREE EXTRÊME R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · Wall-mounted heat pump · 12,000 BTU

FUJITSU AIRSTAGE ORION XLTH and GREE EXTRÊME R32, summer and winter

Two 12,000 BTU R-32 wall units, ENERGY STAR cold-climate certified and offered by AirGreen. In cooling, their SEER2 values are one point apart. In heating, their certified values drift apart. This page shows where, by how much, and at which temperatures.

SEER2 30.5 and 29.5HSPF2 IV 12.7 and 10.0Coldest points: −26.1 and −30 °C
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU (AirGreen image)
FUJITSU AIRSTAGE

ORION XLTH 12,000 BTU

ASUH12KZAS / AOUH12KZAH1 · AHRI 214888802

See the product page
GREE EXTRÊME R32 12,000 BTU (AirGreen image)
GREE

EXTRÊME R32 12,000 BTU

GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O · AHRI 215386290

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The wheel of seasons

One point apart in summer, 2.7 points in winter

The yellow half of the wheel shows cooling, the bluish half heating. In red, the ORION XLTH; in blue, the EXTRÊME R32. Each arc is an AHRI-certified value, on the same scale for both units. Turn the wheel to move from one season to the other.

SUMMER · SEER230.5 and 29.5 WINTER · HSPF2 IV12.7 and 10.0
ORION XLTH outer arcEXTRÊME R32 inner arc

Scales: SEER2 out of 32, HSPF2 out of 14.

Summer: almost even

30.5SEER2 ORION XLTH
29.5SEER2 EXTRÊME R32

One point apart over a cooling season. The EER2, measured at 35 °C outside, follows the same order: 16.0 and 15.2. The GREE brochure prints a SEER2 of 28.0; AHRI certificate 215386290 says 29.5. The certificate prevails.

Winter: a 2.7-point gap

12.7HSPF2 IV ORION XLTH
10.0HSPF2 IV EXTRÊME R32

In Region V, colder, the values are 10.1 and 8.0. Over a heating season, the ORION XLTH is certified for more heat per kilowatt-hour, under the standard’s conditions.

Winter, point by point

What each one can deliver as the temperature drops

The grey area between the two curves is the gap in certified maximum capacity. It does not widen: 7,400 BTU/h at 8.3 °C, 5,700 to −8.3 °C, 4,400 to −15 °C. Proportionally, the ORION XLTH stays 36 to 46% higher at those three points.

Below −15 °C, the direct comparison stops. NEEP measures the ORION XLTH at −26.1 °C (12,200 BTU/h maximum) and the EXTRÊME R32 at −30 °C (8,500 BTU/h). Two temperatures, two points, no “versus”.

At the last shared point, −15 °C, the certified maximum capacities are 16,600 BTU/h (ORION XLTH) and 12,200 BTU/h (EXTRÊME R32). Below −26.1 °C, FUJITSU AIRSTAGE states that the ORION XLTH has no automatic shutoff and keeps heating, with no published capacity; GREE rates a heating range down to −30 °C for the EXTRÊME R32. FUJITSU AIRSTAGE also publishes, outside the certificate, 14,920 BTU/h at −20.6 °C in its technical manual: every point below −15 °C is gathered in “Extreme cold”, just below.

ORION XLTH FUJITSU AIRSTAGE · maximum capacityEXTRÊME R32 GREE · maximum capacity
● NEEP-certified point · line between certified points, indicative · grey area: gap between the twoThe ORION XLTH’s last point is at −26.1 °C: FUJITSU AIRSTAGE states there is no automatic shutoff below that, with no published capacity.
Certified capacity (BTU/h) ORION XLTH EXTRÊME R32
8.3 °C: rated / maximum 16,000 / 23,600 12,200 / 16,200
−8.3 °C: rated / maximum 10,000 / 18,700 13,000 / 13,000
−15 °C: rated / maximum 16,600 / 16,600 12,200 / 12,200
Coldest point: maximumDifferent temperatures 12,200 to −26.1 °C 8,500 to −30 °C

At −8.3 °C, the EXTRÊME R32’s rated capacity (13,000) exceeds the ORION XLTH’s (10,000). It is a setting point each manufacturer chooses for the test; the maximum capacity at the same point is 13,000 and 18,700 BTU/h.

Extreme cold

Below −15 °C: every published number, at its exact temperature

NEEP certifies both units down to −15 °C, at the same temperatures. Lower, each figure is placed at its exact temperature, with its source. Nothing is calculated between two points.

138%at −15 °C
124%at −21 °C
102%at −26 °C

ORION XLTH: maximum heating capacity as a percentage of the 12,000 BTU/h rated capacity, with 21 °C indoors, per FUJITSU AIRSTAGE brochure FG8153C (revision 4/2025). Vertical line: 100%.

What GREE publishes below −15 °C. The NEEP point at −30 °C (8,500 BTU/h, COP 1.75) and a heating range of −30 to 30 °C. The GREE Airy Inverter R32 service manual (GWH12AVDXE models) also plots a capacity curve in percent against outdoor temperature, down to −22 °F. For the 12K, its values are shown in the table above, read directly from the PDF’s plots (accuracy of about 1 point); GREE does not specify the base of that percentage, and the curve does not exactly match the NEEP-certified points.
COP by load

When the unit gives everything it can, the order is not the same everywhere

COP tells how many units of heat come out for one unit of electricity. It depends on the temperature and on how hard the unit is working. At full capacity and 8.3 °C, the EXTRÊME R32 has the higher COP; at −8.3 and −15 °C, it is the ORION XLTH, which also delivers more heat at that moment.

At 8.3 °C, full capacity

ORION XLTH3.07
EXTRÊME R323.77
at 23,600 and 16,200 BTU/h

At −8.3 °C, full capacity

ORION XLTH2.44
EXTRÊME R322.06
at 18,700 and 13,000 BTU/h

At −15 °C, full capacity

ORION XLTH2.16
EXTRÊME R322.00
at 16,600 and 12,200 BTU/h
At rest too. At 8.3 °C and rated capacity, the COPs are 4.64 (ORION XLTH, 16,000 BTU/h) and 4.53 (EXTRÊME R32, 12,200 BTU/h). At the coldest point, the full-capacity COP is 1.81 at −26.1 °C and 1.75 at −30 °C: different temperatures, to be read separately.
Same platform, several names

The EXTRÊME R32 has certified twins

Several wall units carry the same AHRI and NEEP certified values as the GREE EXTRÊME R32 in 12,000 BTU (NEEP “Airy” series). The indoor unit, remote control, app and warranty may differ from one name to the other. The ORION XLTH has no known twin in the lineup; it is also sold under the name GENERAL AIRSTAGE ORION XLTH, same AHRI certificate.

GREE EXTRÊME R32AHRI 215386290
GREE AIRY R32same AHRI certificate
GREE SAPPHIRE R32same NEEP-certified values
KINGHOME AIRY R32same NEEP-certified values
Documented features

What each brochure names

FUJITSU AIRSTAGE brochure FG8153C, GREE Canada EXTRÊME R32 brochure and GREE Airy Inverter R32 service manual, which covers the same model numbers (GWH12AVDXE). Each line cites what the manufacturer writes.

Extreme cold

ORION XLTH: “no lockout” down to −26 °C, heated outdoor base pan, automatic defrost.

EXTRÊME R32: heating rated down to −30 °C; automatic defrost; outdoor unit base pan heating, active at 0 °C and below (service manual).

Cooling in cold weather

ORION XLTH: down to −10 °C outdoors.

EXTRÊME R32: down to −29 °C outside.

Modes

ORION XLTH: Powerful, Economy, Energy Saving, Minimum Heat, Occupancy.

EXTRÊME R32: “G-AI Learning”.

Controls

ORION XLTH: Wi-Fi, AIRSTAGE Mobile app; backlit remote control included; wall controls and 24 V thermostat optional.

EXTRÊME R32: Wi-Fi (app not named); YBE1FB1F remote.

Restart and network

ORION XLTH: automatic restart after a power outage.

EXTRÊME R32: “low-voltage start”; automatic restart with the last settings after a power outage (service manual).

Maintenance and compressor

ORION XLTH: washable filter, ProCore coil; inverter compressor.

EXTRÊME R32: washable filters; “G10 Inverter”.

More recent English versions of the GREE brochure mention a “G20 Inverter” and self-cleaning; the French version on the site says “G10”. This page uses only the French version, without deciding.

Sound

The sound of each, according to its manufacturer

FUJITSU AIRSTAGE publishes six named speeds for the ORION XLTH. GREE publishes eight levels for the EXTRÊME R32, with no speed names. Both give a sound pressure in dB(A).

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer, from the slowest to the fastest.

Why this is not a ranking. FUJITSU AIRSTAGE measures in its own anechoic chamber. GREE publishes neither the distance nor the measurement conditions. A gap of a few dB(A) can come from the method as much as from the unit.

Indoor unit, in the room

Cooling, every published speed

Outdoor unit, outside

Highest published speed

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Sources: FUJITSU AIRSTAGE brochure FG8153C and technical manual DR_AS233ES; GREE Canada EXTRÊME R32 brochure and GREE Airy Inverter R32 service manual (models GWH12AVDXE-D6DNA1A and A1B), which states that these are sound pressure values. GREE also publishes sound power: 29 to 53 dB(A) indoors, 65 dB(A) outside.

Installation

On the ground, on the wall, in the piping

Outdoor unit clearances

ORION XLTH

FUJITSU AIRSTAGE installation manual 9300793025-01, § 3.2.1. Top view, diagram.

EXTRÊME R32

The GREE R32 outdoor unit owner’s manual (X40270A_2, p. 8, Airy, Charmo and Clivia) gives clearances of 30 to 200 cm depending on the side, in a figure. The side for each value is read on the figure; the installer confirms it on site.

Indoor units to scale

ORION XLTH38 9/16 × 11 × 9 7/16 in
ASUH12KZAS indoor unit to scale
38.56 in
EXTRÊME R3238 3/16 × 13 21/32 × 10 1/8 in
GWH12AVDXE indoor unit to scale
38.19 in

Almost the same width; the EXTRÊME R32 is taller (13 21/32 against 11 in) and deeper.

Installation ORION XLTH EXTRÊME R32
Maximum piping length 82 ft 131.2 ftEXTRÊME brochure. The GREE Airy R32 service manual states 65.6 ft for the 12,000 BTU: to be confirmed at the quote.
Precharged length 49 ft 24.6 ftGREE AIRY R32 brochure and service manual (reference length 24.6 ft, 0.2 oz/ft added beyond); the EXTRÊME brochure does not give it.
Maximum height difference 66 ft 82 ftService manual: 32.8 ft.
Liquid – gas diameters 1/4 – 3/8 in 1/4 – 1/2 in
Outdoor unit W × H × D, weight 31 7/16 × 24 7/8 × 11 7/16 in, 86 lb 34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb
Indoor unit, weight 28 lb 33.1 lb
Electrical protectionPer the manufacturer 15 A breaker MOP 15 A (MCA 11 A)
Dehumidification 1.9 L/h 1.4 L/h
Rated heating / cooling range −26 to 24 °C / −10 to 50 °C −30 to 30 °C / −29 to 50 °C
Frequently asked questions

What people ask about these two wall units

Their SEER2 values are almost equal: is there a difference in summer?

The AHRI certificates give 30.5 and 29.5, and EER2 values of 16.0 and 15.2. On these two measures, the gap is small. The difference between these units shows mainly in heating.

Which one heats more at −15 °C?

According to NEEP, 16,600 BTU/h maximum for the ORION XLTH, 12,200 BTU/h for the EXTRÊME R32. This is the lowest temperature at which both are measured under the same conditions.

Why is the EXTRÊME R32 measured at −30 °C and the ORION XLTH at −26.1 °C?

Each manufacturer has its unit measured at the bottom of its rated range: −30 °C for GREE, −15 °F (−26.1 °C) for FUJITSU AIRSTAGE. The EXTRÊME R32’s 8,500 BTU/h at −30 °C and the ORION XLTH’s 12,200 BTU/h at −26.1 °C therefore cannot be compared directly.

GREE EXTRÊME, GREE AIRY, GREE SAPPHIRE: what is the difference?

These models have the same AHRI and NEEP certified values in 12,000 BTU (the EXTRÊME and the AIRY even share certificate 215386290). The indoor unit, remote control, app and warranty may differ depending on the name.

The GREE brochure says SEER2 28.0: why does the page say 29.5?

GREE Canada brochure no. 032025 prints 28.0. AHRI certificate 215386290, repeated by NEEP and ENERGY STAR, shows 29.5. When sources disagree, this page follows the certificate.

Which one is quieter?

Both publish a sound pressure: 23 to 43 dB(A) in cooling for the ORION XLTH, 19 to 43 dB(A) for the EXTRÊME R32. FUJITSU AIRSTAGE measures in its anechoic chamber; GREE does not publish its measurement conditions. These figures place each unit; they do not allow them to be ranked.

Are they eligible for rebates?

Eligibility depends on the official list in effect on the date of purchase. This page promises no amount; the current list is checked at the time of the quote.

Certified record

All AHRI and NEEP values

Certified value ORION XLTH EXTRÊME R32
Cooling
Rated capacity at 35 °C 12,000 BTU/h 12,000 BTU/h
SEER2 30.5 29.5
EER2 16.0 15.2
Heating, same conditions
HSPF2 Region IV / V 12.7 / 10.1 10.0 / 8.0
8.3 °C: min. / rated / max.BTU/h 3,500 / 16,000 / 23,600 3,270 / 12,200 / 16,200
8.3 °C: COP min. / rated / max. 5.13 / 4.64 / 3.07 5.04 / 4.53 / 3.77
−8.3 °C: min. / rated / max.BTU/h 2,200 / 10,000 / 18,700 2,800 / 13,000 / 13,000
−8.3 °C: COP min. / rated / max. 3.39 / 3.45 / 2.44 4.32 / 2.06 / 2.06
−15 °C: min. / rated / max.BTU/h 1,950 / 16,600 / 16,600 2,600 / 12,200 / 12,200
−15 °C: COP min. / rated / max. 3.36 / 2.16 / 2.16 4.23 / 2.00 / 2.00
Coldest point — different temperatures, not highlighted
Test temperature −26.1 °C (−15 °F) −30 °C (−22 °F)
Capacity min. / max. 1,400 / 12,200 BTU/h 2,600 / 8,500 BTU/h
COP at maximum capacity 1.81 1.75
Listings and refrigerant
ENERGY STAR / cold climate (NEEP) Yes / Yes Yes / Yes
ENERGY STAR directory, markets listed United States, Canada United States
AHRI certificate · NEEP record 214888802 · 392122 215386290 · 389444
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class R-32 · GWP 675 · A2L R-32 · GWP 675 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read.

Both are on the AirGreen website.

To choose for your room, talk to our team: bring the room dimensions, the planned outdoor location and your current heating.

Sources and documents

Where each figure comes from