Installation of a TOSOT Inverter wall-mounted heat pump in Villeray (Montreal)
Villeray Duplex: TOSOT Inverter wall-mounted heat pump installed on brackets with anti-vibration mounts and discreet capping. AirGreen ensures efficient and sustainable HVAC installation in Montreal, Laval, Longueuil, North Shore and South Shore.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
A clean, robust HVAC system designed for our winters
At AirGreen , we install heat pumps that must perform in both winter and summer, without ever compromising the building's aesthetics. In this brick duplex in Villeray (Montreal) , our team installed a TOSOT Inverter on exterior wall brackets to serve an interior wall-mounted head. The result: a compact, quiet and easily accessible HVAC installation for HVAC maintenance , perfectly suited to the neighborhood's residential fabric.
Why TOSOT for a Montreal duplex?
TOSOT—a Gree Group brand—offers reliable inverter units, valued for their fine modulation and cold-weather performance. In a typical Montreal building (brick walls, narrow alleys, close neighborhoods), we seek a balance between:
-
seasonal energy efficiency in air conditioning and heating;
-
reduced noise level on the neighborhood side;
-
compactness to preserve the footprint on the facade;
-
accessibility for future interventions.
This unit meets these criteria while blending discreetly into the brick cladding.
Preliminary analysis: brick facade, air circulation and snow management
Before installing the machine, our technicians assess:
-
Clearances required around the condenser to prevent recirculation of hot air in summer and to facilitate defrosting in winter.
-
Installation height : raised to avoid the accumulation of snow and ice, while respecting municipal limits and accessibility for maintenance.
-
Rigidity of the support : a mechanical anchor in the brick (and not in the mortar) to guarantee structural strength.
-
Route of refrigerant connections to the interior head with discreet capping , sealed penetrations and adequate slopes for condensate drainage on the interior side.
Installation on brackets: stability and anti-vibration
The outdoor unit is mounted on galvanized wall brackets sized to the condenser load. We interpose anti-vibration mounts and protective pads (blue in the photo) which:
-
limit the transmission of vibrations to the masonry;
-
reduce the structure-borne noise perceptible inside;
-
extend equipment life by cushioning starts/stops.
The leveling is laser-controlled. The fixings are made of stainless steel or hot-dip galvanized, with sealing suitable for period brick substrates.
Connections, sealing and vacuuming
On the refrigeration side, we:
-
bend and insulate the copper tubes with UV-resistant insulation;
-
add finishing covers to protect exposed sections;
-
we carry out brazing under nitrogen to avoid internal oxidation;
-
We perform a nitrogen pressure test , then a deep vacuum draw to best practice levels (microns), ensuring a healthy charge and compressor longevity.
These steps, invisible once the installation is complete, are nevertheless the key to stable performance and reliable heating in the heart of Montreal's winter.
Power supply: safety and compliance
The TOSOT condenser is connected to a dedicated circuit from the electrical panel, with an outdoor disconnect switch within easy reach (safety and service requirement). We use weather-resistant conduits , watertight cable glands, and code-compliant grounding. Every screw and clamp is chosen to resist corrosion, a critical requirement in a salt and freezing environment.
Settings and commissioning: the AirGreen difference
Careful commissioning immediately optimizes comfort and consumption:
-
superheat/subcool check;
-
calibration of indoor head ventilation speeds ;
-
defrost and airflow tests;
-
usage advice for the owner (recommended temperature ranges, automatic mode management, filter maintenance, clearances to be maintained around the condenser).
Result: a uniform temperature , a discreet noise level and remarkable responsiveness in mid-season.
Salient installation details
-
Building : Brick duplex in Villeray (Montreal)
-
Equipment : TOSOT Inverter , wall-mounted heat pump (outdoor unit on wall)
-
Support : wall brackets with anti-vibration pads
-
Finish : discreet exterior capping, sealed penetrations
-
Objective : efficient additional heating in winter, silent air conditioning in summer
-
Duration of intervention : half a day with two technicians
AirGreen Tips for a Condenser on a Brick Facade
-
Clearances : Maintain manufacturer's clearances on the sides and front; avoid closed recesses.
-
Height : provide sufficient elevation to get through the winter without snow suction.
-
Air outlets : do not direct towards a narrow pedestrian passage or a nearby window.
-
Water management : check the flow during defrosting to avoid creating ice patches.
-
HVAC maintenance : cleaning of fins, inspection of connections, annual check of tightness and operation in heating mode.
Pitfalls to avoid (field experience feedback)
-
Fixings in the mortar : These will eventually come loose with freeze/thaw cycles. Always aim for sound brick.
-
Undersized capping : it opens with expansion and leaves the insulation exposed to UV rays. We size it large and clip it correctly.
-
Air recirculation : Condenser too close to a corner or obstacle. We maintain a clear field in front of the exchanger.
-
No anti-vibration pads : vibrations transmitted to the neighbors' living room. Anti-vibration pads are a must in a dense urban environment.
Grants and Eligibility
Modern, high-efficiency heat pumps that perform well in cold weather may be eligible for assistance programs in Quebec (depending on configuration and technical specifications). When a file is eligible, we assist the owner in gathering evidence (serial numbers, photos, energy assessments) to reduce the net cost of the project.
And after installation? Our maintenance plan
AirGreen offers annual HVAC maintenance , which includes: outdoor coil washing, fan inspection, electrical check, heating and cooling performance testing, capping and insulation inspection, and personalized recommendations. Regular maintenance reduces consumption, prevents capacity loss, and extends the system's lifespan.
What the owner earns
-
Instant four-season comfort ;
-
Clean and safe facade thanks to the raised installation;
-
Noise pollution reduced by the studs and positioning;
-
Quick maintenance access without scaffolding;
-
Improved resale value through careful and documented installation.
AirGreen, your local partner
We work weekly in Montreal, Laval, Longueuil, the North Shore, and the South Shore for wall-mounted , multi-zone , and central heat pump projects. Our promise: clean, compliant, and efficient installations, supported by proactive customer service and certified teams.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).