Four-season comfort and careful installation on a brick facade: an AirGreen project designed to last
Residence context and client objective
In Chomedey, a typical residential area of Laval, we were commissioned to modernize the thermal comfort of a brick house with a vinyl-clad gable. The need was expressed: a quiet, reliable HVAC solution capable of providing heating and cooling at a lower operating cost. We recommended aTosot wall-mounted heat pump —a choice recognized for its value, ease of maintenance, and consistent performance.
Outdoor installation: condenser on wall brackets
To preserve floor space, we proposed a high-level fixing on galvanized brackets directly in the brick.
-
Working height : approx. 2.7–3.0 m, ideal for keeping clear of winter thaws and keeping the device away from flying snow.
-
Vibration treatment : anti-vibration pads under the condenser base to limit transmission to the wall.
-
Free air circulation : side and rear clearances respected to optimize heat exchange and facilitate maintenance.
-
Runoff management : controlled slope under the device so that defrost water flows away from the masonry and pedestrian paths.
Refrigeration and electrical path: clean and watertight capping
The route of the refrigerant connections and the communication cable is carried out in an external duct , harmonized with the casing.
-
Estimated length : ~4 m between wall outlet and outdoor unit, with a service loop for future operations.
-
Drilling : clean penetration of the brick wall with sleeve , fire-resistant foam and interior/exterior sealing .
-
Condensates : gravity drain outside, with continuous slope; no condensate pump required on this configuration.
-
Connections : Dedicated power supply and nearby external disconnection , in accordance with local electrical requirements.
Positioning on the facade side: aesthetics, silence and maintenance
The layout takes into account the porch lamp , the vegetation and the circulation around the entrance:
-
Noise : fan orientation and cycle management to reduce sound perception towards the terrace and living areas.
-
Service : clear access to the service cover, valve and suction filter.
-
Protection : treated steel fixings, anchored in the brick, controlled tightening torques; level checked to ensure the flow of defrost condensate.
Sizing and comfort: the AirGreen approach
Correct sizing is the key to a high-performance heat pump :
-
Building envelope and occupancy patterns analyzed to determine power.
-
Winter heat losses verified to maintain advantageous COPs during cold peaks.
-
Indoor air management: directed diffusion to standardize the temperature and avoid stratification.
Result: a machine that modulates finely, reduces starts/stops , maintains a pleasant humidity level in summer and controlled consumption all year round.
Why Tosot for this project?
-
Proven reliability in residential applications and components compatible with standard HVAC maintenance .
-
Responsive control electronics , useful for mid-season modulation.
-
Parts and consumables available, facilitating long-term maintenance.
(The precise model is not communicated here; we always validate the AHRI nomenclature and operating ranges before endorsing a final reference.)
Quebec winter: good installation practices
On a brick wall in a cold climate, a few rules ensure its longevity:
-
Sufficient clearance under the unit for the evacuation of ice formed during defrosting .
-
No obstruction to air intake/discharge (branches, awnings, guardrails).
-
Controlled tilt of the tray and channeling of droplets to avoid ice cubes on the paths.
-
Snow guard not required here, unit being high up; consider if exposed to prevailing winds.
Waterproofing and energy performance
We seal the crossings and connections to prevent any infiltration of parasitic air . This rigor improves:
-
pressure stability in the envelope,
-
seasonal performance (SEER/HSPF),
-
acoustic comfort by eliminating whistling at the drilling points.
AirGreen commissioning: three-step protocol
-
Deep vacuum and leak test (micron-gage and hold).
-
Opening of valves , control of blowing temperatures and superheating/subcooling according to conditions.
-
User settings : modes, instructions, scanning, schedules, usage advice for winter and heat waves.
Possible grants and eligibilities
Several Quebec programs support heat pump projects when the system meets certified performance criteria and low-temperature operating ranges . Eligibility depends on the exact model and use (replacement of an existing unit, building characteristics, postal codes).
We support each client in verifying criteria , collecting AHRI evidence and preparing files to maximize potential returns.
Recommended maintenance (preserve warranty and performance)
-
Clean the internal filters every 4–8 weeks during the usage season.
-
Gentle rinsing of the external battery in spring and autumn, with the device powered off.
-
Annual inspection by an HVAC technician : connections, line insulation, tightening, electrical measurements and verification of operating parameters.
-
In winter: clear snow around the unit and never obstruct the water drainage holes.
Common Pitfalls to Avoid (and How We Prevent Them)
-
Lines too long without a service loop → pressure losses: we size and insulate correctly, with clamps at the correct center distances.
-
Improvised holes in the brick → cracks and infiltrations: sleeves , professional mastic and fire-resistant foam are systematic.
-
Ground mounting exposed to snowdrifts → over-stress during defrosting: here, wall mounting solves the problem and makes maintenance easier.
-
Unprotected wiring → premature aging: UV ducts and bending radii respected.
Assessment and benefits for the family
From the moment it is switched on, the house gains thermal stability , with a soft and even blowing . Operating costs drop compared to pure electric resistances, and the noise level remains discreet, both on the facade and inside.
Your project in Montreal, Laval, Longueuil, North Shore or South Shore
At AirGreen, we design each HVAC installation based on your building, your uses and local climatic constraints. Whether you are in Montreal , Laval , Longueuil , on the North Shore or the South Shore , our team masters the rules of the art for wall-mounted heat pumps , wall-mounted air conditioners and associated systems.
Need a detailed estimate? We assess the feasibility (line routing, electricity, clearances) on-site, validate grant eligibility based on the model, and provide a clear quote with a work schedule.
Quick Fair (useful before starting)
-
External noise : the elevation on brackets and the choice of location limit reverberation on the masonry.
-
Harsh winter : be careful when defrosting ; the unit must never blow against an obstacle.
-
Warranty : It requires minimal HVAC maintenance and installation in accordance with electrical standards and building codes .
-
Savings : a properly sized heat pump significantly reduces the annual bill and provides constant comfort .
Conclusion
This Tosot installation in Chomedey exemplifies our approach: practical engineering , clean finishes, and turnkey service that respects the aesthetics of the home while preparing the equipment for Laval winters. For a similar project— a wall-mounted heat pump , wall-mounted air conditioner , or multi-zone solution—our team travels throughout Greater Montreal with the same high standards.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).